EEG Study Guide 2026

Everything you need to pass the EEG exam in one place: the exam format, every topic to study, real practice questions with explanations, flashcards, and full-length practice tests. Free, no sign-up needed.

📋 EEG Exam Format at a Glance

200
Questions
180 min
Time Limit
70.00%
Passing Score

📚 EEG Topics to Study (78)

✍️ Sample EEG Questions & Answers

1. What are the typical high-pass and low-pass filter settings used when recording brainstem auditory evoked potentials (BAEPs)?
100–3000 Hz

BAEP waveforms contain frequencies predominantly in the 100–3000 Hz range; these bandpass settings preserve the fast transient potentials while rejecting low-frequency muscle artifact and EEG.

2. Eye closure sensitivity refers to which phenomenon during EEG recording?
Epileptiform discharges triggered specifically by the act of closing the eyes, distinct from normal alpha appearance

Eye closure sensitivity is a form of reflex epilepsy where epileptiform discharges are triggered by the act of closing the eyes, as opposed to the normal alpha rhythm that appears. It is distinct from fixation-off sensitivity.

3. Centrotemporal spikes (rolandic spikes) in a child are associated with which EEG characteristic regarding sleep?
They increase in frequency and may become bilateral during NREM sleep

Centrotemporal spikes in benign epilepsy with centrotemporal spikes (BECTS) are markedly activated and may spread bilaterally during NREM sleep.

4. The standard paper speed (or digital equivalent time base) for routine EEG display is:
30 mm/second

The standard time base for routine EEG is 30 mm/second (equivalent to displaying 10 seconds per standard screen page), which provides optimal visualization of EEG waveform morphology and temporal relationships.

5. A photic driving response seen on EEG during IPS is considered normal when it occurs at:
Harmonic or subharmonic frequencies of the flash rate over the occipital region

Normal photic driving is a rhythmic occipital response at the flash frequency or its harmonics/subharmonics and represents normal visual cortex activation.

6. A patient wearing an ambulatory EEG recorder reports the device became wet after showering despite instructions. The technologist's FIRST concern should be:
Patient electrical safety and device integrity

Patient safety is the primary concern; water ingress into recording equipment can create electrical hazards, and device integrity must be assessed before continuing.