S95 Cheat Sheet 2026
The 30 highest-yield S95 facts, distilled from real exam questions. Print it, save it as a PDF, or study it here — free, no sign-up.
35 questions
53 min time limit
70% to pass
- Which scenario would result in the FDNY suspending or revoking an S-95 certificate? → Failing to maintain the log book and repeatedly neglecting FDNY notifications
- Which component continuously monitors fire alarm field wiring for open circuits, ground faults, and short circuits? → The panel's supervisory circuitry operating on each monitored circuit
- Which NFPA standard, rather than NFPA 72 itself, primarily governs where smoke detectors must be installed within HVAC air distribution ductwork? → NFPA 90A
- Which of the following best describes the primary power source for a Fire Alarm Control Panel (FACP)? → A dedicated branch circuit with a marked and locked circuit breaker.
- After activation, which type of heat detector must be replaced rather than reset? → Fusible-link or fusible-alloy fixed-temperature detector
- The purpose of a 'waterflow retard' on a wet-pipe sprinkler system alarm check valve is to: → Delay the alarm signal to reduce false activations from surges
- The NFPA 72 'record of completion' must be signed by: → The contractor or installer responsible for the installation
- During a fire drill, the S-95 holder's role includes: → Coordinating with building staff and documenting the drill in the log book
- Which consequence can a building owner face for repeatedly ignoring AHJ orders to repair a non-functional fire alarm system? → Forced building closure, fines, and potential criminal liability
- An ionization smoke detector is generally more responsive than a photoelectric detector to: → Fast, flaming fires with small, invisible combustion particles.
- In most US jurisdictions, which agency enforces fire alarm system code compliance in existing commercial buildings? → Local fire marshal or fire prevention bureau
- Per NFPA 72, what is the minimum sound pressure level required for audible notification appliances in sleeping areas? → 75 dB at the pillow
- The 'reset' function on an FACP is primarily used to: → Return the system to normal standby after alarm or trouble conditions have been cleared
- According to NFPA 72, smoke detector sensitivity must first be tested within how long after initial installation? → Within 1 year of installation
- Which of the following events would typically initiate a 'Trouble' signal at the FACP? → A loss of primary AC power to the FACP.
- Visible notification appliances (strobes) are required in locations where: → Ambient noise levels may prevent audible signals from being heard
- A projected beam smoke detector consists of which two primary components? → Transmitter and receiver
- A fire alarm supervisor discovers a technician falsified inspection records. What is the supervisor's legal obligation? → Correct the records and report the falsification
- What is the purpose of a fire alarm system inspection report? → To summarize the findings of routine inspections and any corrective actions taken
- When a notification appliance circuit (NAC) develops an open-circuit fault, the fire alarm control unit will typically: → Display a trouble condition indicating the circuit fault
- Which condition indicates that the OS&Y valve is properly maintained and functioning as intended? → The stem is extended with the yoke in a vertical position.
- Under NFPA 72, sealed lead-acid (SLA) batteries used in fire alarm systems must be replaced at a maximum interval of: → Every 5 years
- Which regulation requires that fire alarm systems in certain federally regulated facilities comply with ADA accessibility standards? → The Americans with Disabilities Act (ADA)
- When does NFPA 72 require a new acceptance test to be performed on an existing fire alarm system? → After any addition, modification, or deletion of system components
- A partially closed sprinkler system control valve would generate which type of FACP signal? → Supervisory signal
- Voice evacuation systems use which type of notification appliance to deliver intelligible emergency instructions? → Speakers
- A fire alarm control unit displays a 'common alarm' condition. This means: → At least one initiating device in the system has activated an alarm condition
- A smoke detector in a corridor repeatedly goes into alarm during early morning hours with no visible smoke present. The MOST likely cause is: → High humidity or condensation affecting the detector chamber
- A fire alarm system 'impairment' is defined as a condition in which: → Part or all of the fire protection system is out of service
- A 'trouble' signal displayed on a fire alarm control panel indicates: → A fault or abnormal condition within the fire alarm system itself