S95 Cheat Sheet 2026

The 30 highest-yield S95 facts, distilled from real exam questions. Print it, save it as a PDF, or study it here โ€” free, no sign-up.

S95 exam key facts

  • The FDNY S-95 Supervision of Fire Alarm Systems exam has 35 multiple-choice questions, each with four answer choices. Source
  • Candidates have 53 minutes to complete the FDNY S-95 Certificate of Fitness exam. Source
  • The FDNY S-95 exam requires a score of at least 70% to earn the Certificate of Fitness, and unanswered questions are scored as incorrect. Source
  • The FDNY S-95 Certificate of Fitness (Supervision of Fire Alarm Systems) has a $25 new application fee, paid online or in person by card, check or money order, with no cash accepted. Source
  • Candidates who fail the FDNY S-95 exam get a failure report and must submit a new application and payment to retake it, and anyone caught cheating can be barred from all Certificate of Fitness exams for up to six months. Source
  • An FDNY S-95 Certificate of Fitness is valid only for the person it is issued to and at one specific location, and it runs on a 3-year renewal cycle. Source
Start the Timed S95 Mock Exam โ†’
35 questions
53 min time limit
70.00% to pass
  1. Which component continuously monitors fire alarm field wiring for open circuits, ground faults, and short circuits? โ†’ The panel's supervisory circuitry operating on each monitored circuit
  2. Which of the following best describes the primary power source for a Fire Alarm Control Panel (FACP)? โ†’ A dedicated branch circuit with a marked and locked circuit breaker.
  3. After activation, which type of heat detector must be replaced rather than reset? โ†’ Fusible-link or fusible-alloy fixed-temperature detector
  4. The purpose of a 'waterflow retard' on a wet-pipe sprinkler system alarm check valve is to: โ†’ Delay the alarm signal to reduce false activations from surges
  5. The NFPA 72 'record of completion' must be signed by: โ†’ The contractor or installer responsible for the installation
  6. During a fire drill, the S-95 holder's role includes: โ†’ Coordinating with building staff and documenting the drill in the log book
  7. Which consequence can a building owner face for repeatedly ignoring AHJ orders to repair a non-functional fire alarm system? โ†’ Forced building closure, fines, and potential criminal liability
  8. An ionization smoke detector is generally more responsive than a photoelectric detector to: โ†’ Fast, flaming fires with small, invisible combustion particles.
  9. In most US jurisdictions, which agency enforces fire alarm system code compliance in existing commercial buildings? โ†’ Local fire marshal or fire prevention bureau
  10. The 'reset' function on an FACP is primarily used to: โ†’ Return the system to normal standby after alarm or trouble conditions have been cleared
  11. According to NFPA 72, smoke detector sensitivity must first be tested within how long after initial installation? โ†’ Within 1 year of installation
  12. Which of the following events would typically initiate a 'Trouble' signal at the FACP? โ†’ A loss of primary AC power to the FACP.
  13. A projected beam smoke detector consists of which two primary components? โ†’ Transmitter and receiver
  14. A fire alarm supervisor discovers a technician falsified inspection records. What is the supervisor's legal obligation? โ†’ Correct the records and report the falsification
  15. What is the purpose of a fire alarm system inspection report? โ†’ To summarize the findings of routine inspections and any corrective actions taken
  16. When a notification appliance circuit (NAC) develops an open-circuit fault, the fire alarm control unit will typically: โ†’ Display a trouble condition indicating the circuit fault
  17. Which condition indicates that the OS&Y valve is properly maintained and functioning as intended? โ†’ The stem is extended with the yoke in a vertical position.
  18. When does NFPA 72 require a new acceptance test to be performed on an existing fire alarm system? โ†’ After any addition, modification, or deletion of system components
  19. A partially closed sprinkler system control valve would generate which type of FACP signal? โ†’ Supervisory signal
  20. Voice evacuation systems use which type of notification appliance to deliver intelligible emergency instructions? โ†’ Speakers
  21. A fire alarm control unit displays a 'common alarm' condition. This means: โ†’ At least one initiating device in the system has activated an alarm condition
  22. A smoke detector in a corridor repeatedly goes into alarm during early morning hours with no visible smoke present. The MOST likely cause is: โ†’ High humidity or condensation affecting the detector chamber
  23. A fire alarm system 'impairment' is defined as a condition in which: โ†’ Part or all of the fire protection system is out of service
  24. A 'trouble' signal displayed on a fire alarm control panel indicates: โ†’ A fault or abnormal condition within the fire alarm system itself
  25. When a trouble signal is received at a protected premises FACP, NFPA 72 requires the trouble signal to be: โ†’ Acknowledged and investigated within 24 hours
  26. An S-95 certificate holder must be present on-site during which activity? โ†’ Any impairment to the fire alarm system
  27. Under NFPA 72, which signal type has the lowest priority at an FACP when multiple signals are present simultaneously? โ†’ Trouble signal
  28. A technician is testing a fire alarm system and disconnects a wire on an initiating device circuit. What is the expected signal to appear on the FACP? โ†’ A trouble signal, because there is a fault in the circuit wiring.
  29. How does a conventional fire alarm system differ from an addressable system in alarm identification capability? โ†’ Conventional systems identify alarms only by zone, not by individual device
  30. What color is typically used to indicate a TROUBLE signal on a fire alarm control panel? โ†’ Yellow or amber

What Practice Test Geeks adds beyond an AI chat for S95

An AI chatbot can quiz you, but it can't reproduce the exam conditions or keep your record. Here you get:

  • A timed, full-length S95 mock exam โ€” 35 questions in 53 minutes with a 70% pass mark, modeled on the official exam's question count and time limit, followed by a score report broken down by exam domain.
  • A fixed S95 question bank: the same test every attempt, so your score is comparable from one try to the next instead of changing with every regenerated quiz.
  • Progress saved on your device: completed tests, scores and missed questions stay in My Progress, so you can retake only what you got wrong.
  • S95 flashcards built from the same question bank.
  • Free S95 practice tests with the correct answer shown after each question.
Start the Timed S95 Mock Exam โ†’
Was this helpful?

How this page was made: written with AI tools and published by Nathan Beja, founder of Practice Test Geeks, who is responsible for its content. Exam facts are checked against the official sources listed below. Not reviewed by a subject-matter expert. Editorial policy

Sources & references

Exam facts on this page (fees, format, dates, passing scores) are checked against these official sources; the date is our last check. Editorial policy

  1. nyc.gov โ€” Fees, renewal, score validity, eligibility, retake policy, score release, test dates, test delivery, exam format, passing score ยท verified Oct 2026