MRI Physics and Safety Basics

Magnetic Resonance Imaging (MRI) uses strong magnetic fields, radiofrequency (RF) pulses, and gradient magnetic fields to produce detailed images of soft tissue, organs, and structures within the body. Unlike X-rays and CT scans, MRI does not use ionizing radiation β€” this makes MRI generally safer for patients, particularly for repeated imaging or imaging of children and pregnant patients. However, MRI creates unique safety hazards related to its extremely strong magnetic fields. Practice with the free MRI - Magnetic Resonance Imaging practice test on PracticeTestGeeks (200+ questions with answer explanations).

The Three MRI Fields

Static magnetic field (B0) β€” the permanent, always-on magnetic field of the MRI scanner, measured in Tesla (T). Clinical MRI scanners typically operate at 1.5T or 3.0T. Research scanners may operate at 7T or higher. The earth's magnetic field is approximately 0.000025T β€” a 1.5T MRI is 60,000 times stronger than earth's magnetic field. The static field extends beyond the scanner bore and creates a fringe field β€” the area outside the magnet that still has significant magnetic field strength. The 5 Gauss line (0.0005T) is the standard boundary for restricting access to cardiac pacemaker patients.

Gradient magnetic fields β€” rapidly switching magnetic fields used for spatial localization during imaging. Gradients are responsible for the loud knocking sounds during an MRI scan. Rapidly changing gradients can induce peripheral nerve stimulation in patients. Radiofrequency (RF) fields β€” RF pulses delivered at specific frequencies excite hydrogen protons in the body's water molecules, producing the MRI signal. RF energy is deposited as heat in tissue β€” measured by Specific Absorption Rate (SAR). Excessive SAR causes tissue heating, which is a critical safety parameter monitored and limited by MRI scanners.

MRI: upcoming dates and official changes
  • Aug 17, 2026: ARRT launched a separate entry-level Imaging Assistant, Magnetic Resonance (I.A.) credential. Applications made Aug. 17–Oct. 14, 2026 paid a reduced $75 fee for testing Oct. 15–Nov. 30, 2026. Applicants after Oct. 14, 2026 pay $225 and can test on or after Jan. 1, 2027. The I.A. exam also requires a scaled section score of 7.5 or higher in MRI Screening and Safety.[4]

Full MRI change history

  • The ARRT MRI postprimary exam has 220 questions: 200 scored and 20 unscored pilot items.[1]
  • The ARRT MRI primary pathway exam has 230 questions: 200 scored and 30 unscored pilot items.[2]
  • The ARRT MRI postprimary exam allows 210 minutes of test time within a 230-minute (3 hour 50 minute) appointment.[1]
  • The ARRT MRI primary pathway exam allows 230 minutes of test time within a 250-minute (4 hour 10 minute) appointment.[2]
  • ARRT exams, including MRI, are scored on a 1–99 scale, and candidates need a total scaled score of 75 to pass.[3]
  • The ARRT MRI postprimary application fee is $225, or $450 for candidates using an NMTCB or ARDMS credential as the supporting category.[4]
  • The ARRT MRI primary pathway application fee is $225.[4]
  • ARRT MRI technologists holding an R.T. credential must complete Continuing Qualifications Requirements (CQR) every 10 years.[5]
  • ARRT MRI credential holders renew every year for $65 and must complete 24 CE credits every two-year biennium.[5]

Numbers in brackets link to the official sources listed under Sources & last verified. Dates that have passed are removed automatically.

MRI Exam at a Glance

ItemDetailSource Β· Verified
Number of questions (Postprimary pathway)220 questions (200 scored + 20 pilot)[1]assets-us-01.kc-usercontent.com Β· Oct 16, 2026
Number of questions (Primary pathway)230 questions (200 scored + 30 pilot)[2]assets-us-01.kc-usercontent.com Β· Oct 16, 2026
Time limit (Postprimary pathway)210 minutes test time (230-minute appointment)[1]assets-us-01.kc-usercontent.com Β· Oct 16, 2026
Time limit (Primary pathway)230 minutes test time (250-minute appointment)[2]assets-us-01.kc-usercontent.com Β· Oct 16, 2026
Passing scoreScaled score of 75 (scale 1–99)[3]The American Registry of Radiologic Technologists Β· Oct 18, 2026
Exam fee (Postprimary pathway)$225 application fee ($450 with an NMTCB or ARDMS supporting credential)[4]The American Registry of Radiologic Technologists Β· Oct 18, 2026
Exam fee (Primary pathway)$225 application fee[4]The American Registry of Radiologic Technologists Β· Oct 18, 2026
ValidityContinuing Qualifications Requirements (CQR) every 10 years[5]assets-us-01.kc-usercontent.com Β· Oct 16, 2026
RenewalAnnual renewal, $65/year; 24 CE credits every 2 years[5]assets-us-01.kc-usercontent.com Β· Oct 16, 2026
DeliveryComputer-based at Pearson VUE test centers[2]assets-us-01.kc-usercontent.com Β· Oct 16, 2026
Eligibility (Postprimary pathway)Supporting credential (ARRT, NMTCB or ARDMS) + structured education + clinical experience[1]assets-us-01.kc-usercontent.com Β· Oct 16, 2026
Eligibility (Primary pathway)ARRT-verified MRI program + associate degree or higher + ethics[2]assets-us-01.kc-usercontent.com Β· Oct 16, 2026
Score releasePreliminary score at the test center; official results in about 10 business days[3]The American Registry of Radiologic Technologists Β· Oct 18, 2026
Testing windowOne-year exam window per application[2]assets-us-01.kc-usercontent.com Β· Oct 16, 2026

Free MRI - Magnetic Resonance Imaging Study Tools

Interactive MRI - Magnetic Resonance Imaging resources on PracticeTestGeeks, free to start:

MRI Zone System (ACR Zone Classification)

The American College of Radiology (ACR) MRI Safety Committee has defined a four-zone system for MRI facilities to organize access control, reduce projectile hazards, and protect patients, staff, and visitors. Understanding the zone system is essential knowledge for MRI technologists, radiologists, and anyone working in or visiting MRI facilities.

Zone I: General Public Area

Zone I is freely accessible to the general public β€” hallways, waiting rooms, and registration areas that are outside the MRI suite. No MRI-related restrictions apply in Zone I. Standard hospital policies (HIPAA, visitor policies) apply.

Zone II: Unscreened Patient and Visitor Area

Zone II is the interface between the freely accessible Zone I and the controlled Zones III and IV. Zone II includes patient interview areas, changing rooms, and pre-screening areas where MRI technologists perform initial patient screening (medical history, MRI questionnaires). Zone II is supervised and controlled but not yet restricted to screened individuals only.

Zone III: Controlled Access β€” Strong Fringe Field

Zone III is the area immediately outside the MRI scan room where the fringe field is present. Only MRI safety-trained personnel and patients who have completed full MRI screening may enter Zone III. Ferromagnetic objects entering Zone III are at risk of projectile acceleration as they get closer to the magnet. Zone III must be physically secured β€” locked door or controlled access. All individuals entering Zone III must have completed Level 1 (basic MRI safety awareness) training at minimum.

Zone IV: The Magnet Room

Zone IV is the MRI scan room itself β€” the area containing the MRI magnet. Zone IV is the most hazardous area. The magnet is always on (even when not actively scanning) and must be treated as a live, powerful magnet at all times. Only fully screened individuals may enter Zone IV. All staff working in Zone IV must have Level 2 (MRI-specific) safety training. Ferromagnetic items brought into Zone IV may become dangerous projectiles.

MRI Hazards

MRI creates several categories of safety hazards that must be actively managed through screening, access control, and safe practice protocols.

Projectile Hazard (Missile Effect)

The projectile hazard is the most immediately dangerous MRI hazard. Ferromagnetic objects β€” objects attracted to magnets β€” that are brought into the MRI scan room experience a powerful attractive force toward the magnet. Larger, heavier ferromagnetic objects can be accelerated to dangerous velocities by the magnetic field, turning them into missiles capable of causing serious injury or death to patients and staff in the scan room. Common projectile hazards that have caused MRI incidents: IV poles, oxygen tanks, wheelchairs, gurneys, keys, scissors, tools, floor buffers, and equipment not labeled 'MRI Safe.' Preventing projectile hazards: strict ferromagnetic screening of all individuals and equipment entering Zone III and IV; dedicated MRI-safe versions of all necessary equipment (oxygen tanks, IV poles, wheelchairs); ferromagnetic detection systems at Zone III entry points.

Implant and Device Hazards

Metallic implants in or on patients can create serious MRI hazards: Torque β€” the magnetic field exerts a rotational force on ferromagnetic implants; Displacement β€” ferromagnetic implants may be pulled or pushed by the magnetic field; Heating β€” RF energy can heat metallic implants, particularly elongated metallic objects (leads, wires, guidewires), causing tissue burns; Device malfunction β€” electronic implanted devices (pacemakers, neurostimulators, cochlear implants) may malfunction or be damaged in the MRI environment. Not all metallic implants are equally dangerous β€” many modern implants are manufactured from non-ferromagnetic materials (titanium, stainless steel grades) and are considered MR Conditional or MR Safe.

Acoustic Noise Hazard

MRI gradient coils produce loud knocking and clicking sounds during imaging β€” typically 80 to 120 dB at the patient's ear level during a scan. This exceeds OSHA occupational noise exposure limits for extended periods. All patients should receive hearing protection (earplugs or MRI-compatible headphones) during scanning. Staff entering the scan room during active scanning must also use hearing protection.

RF Heating and SAR

Radiofrequency energy is deposited as heat in tissue β€” measured by Specific Absorption Rate (SAR) in Watts per kilogram. MRI scanners monitor and limit SAR automatically based on patient weight and sequence parameters. SAR is of particular concern for: implanted metallic devices that can concentrate RF energy; pregnant patients (concern for fetal heating); patients with impaired thermoregulation.

For a fuller set of questions on this topic, see our cpt 72195 resource.

MRI Patient Screening

Patient screening is the most critical MRI safety practice β€” every patient must be screened before entering Zone III or IV. Inadequate screening is the primary cause of preventable MRI safety incidents.

MRI Screening Process

The standard MRI screening process: All patients complete a written MRI screening questionnaire prior to the exam β€” the questionnaire covers medical history, implants, devices, and prior MRI experiences. A trained MRI personnel member reviews the completed questionnaire with the patient verbally β€” patients may not fully understand which items on the form are relevant, may not recall surgical history accurately, or may have difficulty reading.

For any positive responses on the questionnaire (implants, devices, possible metal fragments, prior surgery), the MRI team must determine whether the item represents a contraindication, requires further investigation, or is safe to proceed. If there is any uncertainty about a metallic implant or device, MRI must not proceed until the item is identified and cleared. The Medical Director or referring physician may need to authorize proceeding in complex cases. Verbal consent β€” patients must understand why they cannot have certain items in the scanner and should actively participate in the screening process.

MRI Contraindications

Absolute contraindications to MRI (items that prevent MRI in any circumstance without extraordinary measures): Ferromagnetic intracranial aneurysm clips (older clips β€” modern clips are often MR Conditional); Pacemakers and implantable cardioverter-defibrillators (ICDs) β€” most older devices are not MRI-compatible; however, many modern devices are specifically labeled MR Conditional and can be safely scanned under specific conditions by a trained team; Cochlear implants β€” most are contraindicated, though some newer devices are MR Conditional; Ferromagnetic intraocular foreign bodies (metal fragments in the eye) β€” absolute contraindication; the magnetic force can cause serious eye injury or blindness.

Relative contraindications (require careful evaluation): Non-ferromagnetic metallic implants (orthopedic hardware, surgical clips) β€” usually safe but require identification and confirmation; Programmable or implanted electronic devices (insulin pumps, neurostimulators) β€” require device-specific evaluation; Intrauterine devices (IUDs) β€” most are MR Safe or MR Conditional; Pregnancy β€” first trimester MRI requires clinical justification, but MRI is generally considered safer than ionizing radiation alternatives when imaging is necessary.

MRI Implant Safety Classifications

The International Electrotechnical Commission (IEC) and the American Society for Testing and Materials (ASTM) have established standardized MRI safety classification terms for implants and devices. These terms must be understood by all MRI personnel.

MRI Safety Labeling

MR Safe β€” the item contains no metallic, magnetic, or electrically conductive material and poses no known MRI hazard in any MRI environment. Items labeled MR Safe can be brought into any Zone IV without restriction. Examples: most plastic items, ceramic materials, glass, some silicone devices. MR Conditional β€” the item has been demonstrated to pose no known hazard in a specified MRI environment with specified conditions of use. These conditions typically include: a maximum static field strength (e.g., 1.5T only, or up to 3.0T); a maximum gradient field (dB/dt); a maximum RF field (SAR). MR Conditional items may be used in MRI if and only if the specific conditions are met.

Always obtain the specific device's MR Conditional documentation before proceeding. MR Unsafe β€” the item is known to pose hazards in all MRI environments and must not be brought into Zone III or IV. Ferromagnetic surgical tools, aneurysm clips made of ferromagnetic alloys, and most consumer electronics are MR Unsafe. When labeling is unknown β€” if a device or implant cannot be identified and its MRI safety status confirmed, it should be treated as MR Unsafe until confirmed otherwise.

Key Implant Considerations

Orthopedic hardware β€” most modern orthopedic hardware (hip replacements, knee implants, spinal fusion hardware, plates, screws) is manufactured from non-ferromagnetic materials (titanium, 316L stainless steel, cobalt-chromium alloys) and is generally MR Conditional or MR Safe. The specific implant manufacturer and model must be confirmed. Cardiac stents and vascular clips β€” most are manufactured from non-ferromagnetic metals and are safe after a waiting period for tissue integration (typically 6 to 8 weeks). Ferromagnetic aneurysm clips β€” older aneurysm clips (placed before approximately 1990) are the highest-risk intracranial implant.

The clip manufacturer, model, and material must be confirmed before MRI β€” if unknown, neurosurgical consultation is required. Tattoos and permanent makeup β€” tattoo inks containing iron oxide pigments can heat during MRI and cause skin irritation or burns. Tattoos over the imaging area should be reported. Pregnancy β€” MRI during pregnancy is generally considered acceptable when the benefit outweighs risk; gadolinium contrast is avoided during pregnancy.

MRI Checklist

Know the ACR Zone system: Zones I-IV and the access restrictions for each zone
Never bring ferromagnetic objects into Zone III or IV without explicit clearance
Complete MRI safety training: Level 1 (general awareness) and Level 2 (MRI-specific) as required for your role
Screen all patients with the written MRI questionnaire AND verbal review before Zone III entry
Confirm MRI safety classification (MR Safe, MR Conditional, MR Unsafe) for any unknown implant or device
Never proceed if implant safety status is unknown β€” treat as MR Unsafe until confirmed
Ensure all patients receive hearing protection before entering Zone IV during active scanning
Know your facility's emergency response protocols: patient emergency, projectile event, quench procedure
Monitor SAR continuously during scanning β€” limit scan parameters if SAR approaches limits
Verify MR Conditional device parameters (field strength, SAR, gradient limits) are met before scanning
Free MRI - Magnetic Resonance Imaging Test

MRI Practice Test Questions

Prepare for the MRI - Magnetic Resonance Imaging exam with our free practice test modules. Each quiz covers key topics to help you pass on your first try.

MRI Knowledge
MRI Exam Questions covering Knowledge. Master MRI Test concepts for certification prep.
MRI Physics
Free MRI Practice Test featuring Physics. Improve your MRI Exam score with mock test prep.
MRI Registry
MRI Mock Exam on Registry. MRI Study Guide questions to pass on your first try.
MRI Anatomy and Pathology
MRI Test Prep for MRI Anatomy and Pathology. Practice MRI Quiz questions and boost your score.
MRI Anatomy and Positioning
MRI Questions and Answers on MRI Anatomy and Positioning. Free MRI practice for exam readiness.
MRI Artifacts
MRI Mock Test covering MRI Artifacts. Online MRI Test practice with instant feedback.
MRI Contrast Agents
Free MRI Quiz on MRI Contrast Agents. MRI Exam prep questions with detailed explanations.
MRI Patient Care and Positioning
MRI Practice Questions for MRI Patient Care and Positioning. Build confidence for your MRI certification exam.
MRI Pulse Sequences
MRI Test Online for MRI Pulse Sequences. Free practice with instant results and feedback.
MRI Safety
MRI Study Material on MRI Safety. Prepare effectively with real exam-style questions.
MRI Sequences and Protocols
Free MRI Test covering MRI Sequences and Protocols. Practice and track your MRI exam readiness.

MRI Pros and Cons

Pros

  • MRI has a defined, publicly available content blueprint β€” candidates know exactly what to prepare for
  • Multiple preparation pathways (self-study, courses, coaching) accommodate different learning styles and schedules
  • A growing ecosystem of study resources means candidates at any budget level can access quality preparation materials
  • Clear score reporting allows candidates to identify specific strengths and weaknesses for targeted remediation
  • Professional recognition associated with strong performance provides tangible career and academic benefits

Cons

  • The scope of tested content requires substantial preparation time that competes with existing professional or academic commitments
  • No single resource covers the full content scope β€” candidates typically need multiple study tools for comprehensive preparation
  • Test anxiety and exam-day performance variability mean preparation effort does not always translate linearly to scores
  • Registration, preparation, and potential retake costs accumulate into a significant financial investment
  • Content and format can change between exam versions, making older preparation materials less reliable

Pros and Cons at a Glance

ProsCons
MRI has a defined, publicly available content blueprint β€” candidates know exactly what to prepare forThe scope of tested content requires substantial preparation time that competes with existing professional or academic commitments
Multiple preparation pathways (self-study, courses, coaching) accommodate different learning styles and schedulesNo single resource covers the full content scope β€” candidates typically need multiple study tools for comprehensive preparation
A growing ecosystem of study resources means candidates at any budget level can access quality preparation materialsTest anxiety and exam-day performance variability mean preparation effort does not always translate linearly to scores
Clear score reporting allows candidates to identify specific strengths and weaknesses for targeted remediationRegistration, preparation, and potential retake costs accumulate into a significant financial investment
Professional recognition associated with strong performance provides tangible career and academic benefitsContent and format can change between exam versions, making older preparation materials less reliable

Sample MRI - Magnetic Resonance Imaging Practice Questions

Try these questions from our free MRI - Magnetic Resonance Imaging practice tests. The correct answer and an explanation follow each question.

  1. Which MRI-specific safety topic is explicitly listed under the ARRT exam content specifications within Patient Care and Education?

    • A. Radiofrequency power amplifier maintenance
    • B. Screening for implants and metallic foreign bodies
    • C. Cryogen manufacturing standards
    • D. Gradient coil winding techniques

    Answer: B. Screening for implants and metallic foreign bodies

    Screening patients for implants and metallic foreign bodies is a core patient safety responsibility explicitly included in the content specifications.

  2. On the ARRT MRI registry exam, which content area covers patient care, contrast agents, and MRI safety screening?

    • A. Image Production
    • B. Patient Care and Education
    • C. Procedures
    • D. Physics and Instrumentation

    Answer: B. Patient Care and Education

    Patient Care and Education encompasses screening, safety, contrast administration, and patient communication topics.

  3. What is the term for the MRI safety classification that indicates a device has been tested and found safe under specified conditions?

    • A. MR Safe
    • B. MR Conditional
    • C. MR Unsafe
    • D. MR Compatible

    Answer: B. MR Conditional

    MR Conditional means the device poses no known hazards when used within the specific conditions (field strength, SAR, gradient limits) stated by the manufacturer.

  4. Which labeling term indicates that an item has been tested and poses no known hazards in ALL MRI environments?

    • A. MR Conditional
    • B. MR Compatible
    • C. MR Safe
    • D. MR Approved

    Answer: C. MR Safe

    The ASTM 'MR Safe' label means the item poses no known hazards in all MRI environments and is made of non-conductive, non-magnetic, non-RF-reactive materials.

Take the full MRI - Magnetic Resonance Imaging practice test

MRI Questions and Answers

Is MRI safe during pregnancy?

MRI during pregnancy is generally considered acceptable when clinical benefits outweigh potential risks, particularly when the imaging is necessary and alternatives (such as CT with ionizing radiation) pose greater risk. MRI is not known to cause fetal harm, but the evidence base for first-trimester MRI is limited. First-trimester MRI requires clinical justification. Gadolinium contrast agents are generally avoided during pregnancy due to theoretical concerns about gadolinium crossing the placenta. Always consult with the referring physician and radiologist regarding the appropriateness of MRI during pregnancy for specific clinical situations.

Can you have an MRI with a pacemaker?

Traditional pacemakers and ICDs were considered absolute MRI contraindications because the magnetic field could cause device malfunction, lead heating, or pacing inhibition. However, many modern cardiac devices (since approximately 2011) are manufactured and labeled as MR Conditional β€” meaning they can be safely scanned under specific conditions (typically 1.5T only, specific SAR limits, specific device programming protocols). An MR Conditional pacemaker patient should be scanned only at facilities with dedicated MRI-conditional pacemaker protocols, in collaboration with cardiology, with the device programmer available, and with careful monitoring. Never assume any pacemaker is MR Safe β€” verify the specific device's label and conditions.

What is the MRI Zone system?

The ACR MRI Zone system defines four zones for MRI facilities based on proximity to the magnet and magnetic field strength: Zone I (general public, unrestricted); Zone II (patient screening area, supervised); Zone III (restricted, strong fringe field β€” must be locked and controlled, only screened individuals may enter); Zone IV (magnet room β€” most hazardous, requires full screening and Level 2 MRI safety training). The Zone system provides a systematic framework for access control, staff training, and hazard prevention in MRI facilities.

What does MR Conditional mean?

MR Conditional is an ASTM-standard term indicating that an implant or device has been tested and demonstrated to be safe in an MRI environment only when specific conditions are met. These conditions typically include: maximum static magnetic field strength (e.g., 1.5T only); maximum gradient field rate; maximum RF energy (SAR). An MR Conditional implant cannot be assumed safe β€” the specific conditions must be verified and met for every scan. The implant manufacturer's documentation or reference databases (such as MRIsafety.com) must be consulted to obtain the specific MR Conditional parameters for each device.

What items are not allowed in the MRI room?

Items that must not enter Zone III or IV without explicit MRI safety clearance include: any ferromagnetic metal items (most steel tools and equipment, scissors, coins, keys, standard oxygen tanks, standard wheelchairs and gurneys); electronic devices not labeled MR Safe (phones, standard medical devices, infusion pumps); cardiac pacemakers and ICDs not labeled MR Conditional; cochlear implants not labeled MR Conditional; ferromagnetic aneurysm clips; patients with unknown metallic implants or fragments. All equipment used in Zone IV must be explicitly labeled MR Safe or MR Conditional with documented conditions verified to be met.

What causes the loud noise during an MRI scan?

The loud knocking, tapping, and clicking noises during MRI scanning are caused by the gradient coils β€” electromagnetic coils inside the MRI scanner that rapidly switch on and off to create the varying magnetic fields needed for spatial image localization. When gradient currents switch rapidly in the presence of the strong static magnetic field, the coils vibrate due to Lorentz forces, producing the characteristic loud sounds. Noise levels typically range from 80 to 120 dB at the patient's ear β€” exceeding occupational noise exposure limits. All patients should be given hearing protection (earplugs or MRI-compatible headphones) before entering the scanner.

How many questions are on the MRI?

The ARRT MRI postprimary exam has 220 questions: 200 scored and 20 unscored pilot items. (Verified Oct 28, 2026 against assets-us-01.kc-usercontent.com.)

How long is the MRI?

The ARRT MRI postprimary exam allows 210 minutes of test time within a 230-minute (3 hour 50 minute) appointment. (Verified Oct 28, 2026 against assets-us-01.kc-usercontent.com.)

What is the passing score for the MRI?

ARRT exams, including MRI, are scored on a 1–99 scale, and candidates need a total scaled score of 75 to pass. (Verified Oct 28, 2026 against The American Registry of Radiologic Technologists.)

How much does the MRI cost?

The ARRT MRI postprimary application fee is $225, or $450 for candidates using an NMTCB or ARDMS credential as the supporting category. (Verified Oct 28, 2026 against The American Registry of Radiologic Technologists.)

Sources & last verified

  1. assets-us-01.kc-usercontent.com β€” number of questions, time limit, eligibility (official source). β€œMRI Scored Items 200 Pilot Items 20 Total Items 220 Test Time 210 min” Verified Oct 16, 2026.
  2. assets-us-01.kc-usercontent.com β€” number of questions, time limit, delivery, eligibility (official source). β€œMRI Scored Items 200 Pilot Items 30 Total Items 230 Test Time 230 min” Verified Oct 16, 2026.
  3. The American Registry of Radiologic Technologists β€” passing score, score release (official source). β€œOur exam scoring scale ranges from 1 to 99, and you’ll need a total score of 75 to pass the exam.” Verified Oct 18, 2026 Β· source checked Oct 18, 2026.
  4. The American Registry of Radiologic Technologists β€” exam fee, other (official source). β€œPostprimary (M, CT, MR, BD, CI, VI, VS, BS, R.R.A.): $225 Postprimary (CT, MR, BD, or VSβ€”using NMTCB as supporting category): $450 Postprimary (MR, VS,…” Verified Oct 18, 2026 Β· source checked Oct 18, 2026.
  5. assets-us-01.kc-usercontent.com β€” validity, renewal (official source). β€œCompleting your Continuing Qualifications Requirements (CQR) every 10 years (if you have an R.T. or R.R.A. credential)” Verified Oct 16, 2026 Β· source checked Oct 16, 2026.

How we verify: editorial & fact-checking policy. Report an error: contact us.

β–Ά Start Quiz