| Item | Detail | Official source |
|---|---|---|
| Number of questions | 200 multiple-choice questions (175 scored + 25 unscored pretest) | Examination Board of Professional Home Inspectors |
| Passing score | 500 on a 200โ800 scaled score | Examination Board of Professional Home Inspectors |
| Exam fee | $225 per test (most US states and Canada) | Examination Board of Professional Home Inspectors |
| Retake policy | Unlimited retakes, 30-day wait between attempts | test-takers.psiexams.com |
| Validity | Registration fee valid 1 year; non-refundable | test-takers.psiexams.com |
| Delivery | Computer-based at 300+ test centers in the US and Canada | Examination Board of Professional Home Inspectors |
| Eligibility | No national prerequisites; state licensing rules apply | Examination Board of Professional Home Inspectors |
| Testing window | Year-round, on demand (advance registration required) | Examination Board of Professional Home Inspectors |
Facts verified Oct 18, 2026 against Examination Board of Professional Home Inspectors. Dates that have passed are removed automatically.
Interactive Home Inspector Test resources on PracticeTestGeeks, free to start:
Prepare for the Home Inspector Test exam with our free practice test modules. Each quiz covers key topics to help you pass on your first try.
Try these questions from our free Home Inspector Test practice tests. The correct answer and an explanation follow each question.
An inspector in a basement observes a steel support column (lally column) that is not perfectly vertical and shows significant rust and flaking at its base. This condition should be reported as a defect PRIMARILY because:
Answer: D. The lean indicates a potential shift in load, and corrosion can significantly reduce the column's load-bearing capacity.
A leaning or tilted steel column indicates a potential shift in the foundation or the load it supports, which is a serious structural concern. Furthermore, significant rust and flaking, especially at the base where moisture often collects, can severely weaken the steel and compromise its structural integrity and load-bearing capacity, potentially leading to collapse.
When inspecting a forced-air furnace system, an inspector notes that the metal flue pipe has a horizontal run of 8 feet before it enters the chimney. For proper drafting of exhaust gases, this horizontal pipe should:
Answer: C. Have a continuous upward slope towards the chimney
The flue vent for a standard-efficiency furnace must have a continuous upward slope from the furnace to the chimney, typically a minimum of 1/4 inch per foot of horizontal run. This upward slope helps the hot, buoyant exhaust gases to vent naturally and prevents condensation from running back into the furnace.
A home inspector notices the furnace flue pipe has a downward slope toward the furnace. What is the concern?
Answer: B. Combustion gases may backdraft into the living space
Flue pipes must slope upward (minimum 1/4 inch per foot) toward the chimney so combustion gases draft properly and do not back-flow into the home.
What is 'blocking' between floor joists primarily intended to accomplish in structural framing?
Answer: A. Prevent joists from rotating or twisting (lateral buckling) and transfer loads between joists
Solid blocking or bridging between joists prevents lateral rotation, distributes point loads across multiple joists, and stiffens the floor system.