Facts verified Oct 18, 2026 against Examination Board of Professional Home Inspectors. Dates that have passed are removed automatically.
| Item | Detail | Official source |
|---|---|---|
| Number of questions | 200 multiple-choice questions (175 scored + 25 unscored pretest) | Examination Board of Professional Home Inspectors |
| Passing score | 500 on a 200โ800 scaled score | Examination Board of Professional Home Inspectors |
| Exam fee | $225 per test (most US states and Canada) | Examination Board of Professional Home Inspectors |
| Retake policy | Unlimited retakes, 30-day wait between attempts | test-takers.psiexams.com |
| Validity | Registration fee valid 1 year; non-refundable | test-takers.psiexams.com |
| Delivery | Computer-based at 300+ test centers in the US and Canada | Examination Board of Professional Home Inspectors |
| Eligibility | No national prerequisites; state licensing rules apply | Examination Board of Professional Home Inspectors |
| Testing window | Year-round, on demand (advance registration required) | Examination Board of Professional Home Inspectors |
Facts verified Oct 18, 2026 against Examination Board of Professional Home Inspectors. Dates that have passed are removed automatically.
Prepare for the Home Inspector Test exam with our free practice test modules. Each quiz covers key topics to help you pass on your first try.
Try these questions from our free Home Inspector Test practice tests. The correct answer and an explanation follow each question.
When inspecting a flat roof, a home inspector finds blistering in the membrane. What is the most likely cause?
Answer: B. Trapped moisture or air beneath the membrane
Blistering in flat roof membranes is caused by trapped moisture or air that expands with heat, separating layers of the roofing material.
Which condition is a home inspector MOST likely to flag regarding a wood-burning fireplace?
Answer: B. Creosote buildup inside the flue
Creosote is a flammable byproduct of burning wood that accumulates in flues and is a leading cause of chimney fires.
A home built in 1965 has ungrounded two-prong outlets throughout. A seller has replaced some with three-prong outlets without rewiring. What should the inspector note?
Answer: B. The added third prong is a false ground unless the circuit was rewired or a GFCI outlet was installed and labeled 'No Equipment Ground'
Installing a three-prong outlet on an ungrounded circuit creates a false sense of safety unless GFCI protection is added and the outlet labeled as having no equipment ground.
What does a home inspector look for when evaluating roof ventilation adequacy using the 1:150 rule?
Answer: A. One square foot of vent area for every 150 square feet of attic floor area without a vapor barrier
The 1:150 ratio requires 1 square foot of net free ventilation area for every 150 square feet of attic floor space when no vapor barrier is present.
Interactive Home Inspector Test resources on PracticeTestGeeks, free to start: