S-95 Holder Responsibilities Flashcards

21 cards from real S95 practice questions. Tap to flip, then mark Knew It or Still Learning — missed cards come back until you master them.

Read the first 20 S-95 Holder Responsibilities flashcards as text
  1. An S-95 certificate holder must be present on-site during which activity?

    Answer: Any impairment to the fire alarm system

    The S-95 holder must be present and supervise any impairment, bypass, or testing of the fire alarm system.

  2. How long must an S-95 holder retain fire alarm test and inspection records on the premises?

    Answer: 3 years

    FDNY requires that fire alarm test and inspection records be kept on the premises for a minimum of 3 years.

  3. When the S-95 holder cannot be present during a planned fire alarm impairment, what must occur?

    Answer: Another qualified S-95 holder must supervise in their place

    If the primary S-95 holder is unavailable, another individual holding a valid S-95 certificate must be designated to supervise the impairment.

  4. Which document must an S-95 holder maintain that logs every alarm, trouble signal, and supervisory signal?

    Answer: Fire alarm log book

    The S-95 holder is responsible for maintaining a fire alarm log book that records all signals, tests, and system events.

  5. The FDNY must be notified BEFORE a planned impairment to the fire alarm system that will last longer than:

    Answer: 1 hour

    The FDNY must be notified in advance of any planned fire alarm system impairment expected to exceed one hour.

  6. An S-95 certificate holder discovers a malfunctioning smoke detector in a corridor. What is the FIRST action to take?

    Answer: Log the trouble condition and notify the building owner and fire alarm company

    Upon discovering a malfunction, the S-95 holder must immediately log the trouble condition and notify the building owner and the fire alarm service company.

  7. Which of the following is the S-95 holder NOT responsible for?

    Answer: Physically repairing and rewiring fire alarm devices

    Physical repair and rewiring of fire alarm equipment must be performed by a licensed fire alarm technician, not the S-95 holder.

  8. Under FDNY rules, the S-95 certificate holder must ensure that fire alarm system tests are conducted at minimum:

    Answer: Annually

    FDNY requires at least an annual inspection and test of the fire alarm system, conducted by a licensed fire alarm company under S-95 supervision.

  9. A fire alarm panel shows a 'supervisory' signal. As the S-95 holder, what does this indicate?

    Answer: A non-emergency condition affecting a system component requires attention

    A supervisory signal indicates a non-emergency abnormal condition, such as a valve position change, that needs to be investigated and corrected.

  10. An S-95 holder's certificate is issued by:

    Answer: The NYC Fire Department (FDNY)

    The S-95 Certificate of Fitness is issued by the New York City Fire Department (FDNY).

  11. During a fire drill, the S-95 holder's role includes:

    Answer: Coordinating with building staff and documenting the drill in the log book

    The S-95 holder must coordinate the fire drill with building staff and accurately document the event in the fire alarm log book.

  12. A tenant installs a supplementary alarm device without notifying building management. What is the S-95 holder's responsibility?

    Answer: Report the unauthorized device and ensure it is evaluated by a licensed technician

    Unauthorized modifications to a fire alarm system must be reported; a licensed technician must evaluate whether the device meets code before it can remain.

  13. When an automatic fire alarm activation occurs in the building, the S-95 holder must:

    Answer: Investigate the cause, document the event, and reset the system only after verifying safety

    After an activation, the S-95 holder must investigate the cause, log all details, and reset the panel only after confirming there is no actual fire or hazard.

  14. If the S-95 holder's certificate expires, they must:

    Answer: Immediately cease all S-95 supervisory duties until the certificate is renewed

    An expired S-95 certificate is invalid; the holder may not perform S-95 duties until the certificate is renewed through FDNY.

  15. The S-95 holder is on a premises where a partial zone is taken out of service for renovation. What is required?

    Answer: Notify FDNY and post a fire watch in the affected area if required

    When a zone is impaired, FDNY must be notified and a fire watch must be posted in accordance with FDNY regulations if required.

  16. Which of the following signals requires the MOST urgent response from the S-95 holder?

    Answer: Alarm signal indicating a smoke detector activation

    An alarm signal indicating smoke or fire detection requires the most urgent response, including investigation and potential evacuation, as it may indicate a real fire.

  17. The S-95 holder must ensure that the Certificate of Fitness is:

    Answer: Posted or available on the premises where they are responsible

    The S-95 Certificate of Fitness must be available on the premises where the holder performs their duties and must be produced upon FDNY request.

  18. A contractor performing work accidentally damages a pull station. The S-95 holder should FIRST:

    Answer: Log the damage, notify the fire alarm company, and implement a fire watch if required

    Any damage to a fire alarm device must be logged, the fire alarm company must be notified for proper repair, and a fire watch implemented if required by FDNY.

  19. Under FDNY rules, who may reset a fire alarm system after an activation?

    Answer: The S-95 holder or a licensed fire alarm technician after investigation

    The fire alarm system may only be reset by the S-95 holder or a licensed fire alarm technician after the cause of the activation has been investigated.

  20. An S-95 holder at a high-rise office building must ensure occupants on affected floors are notified via the alarm system using:

    Answer: The voice communication system or alarm notification appliances per the fire safety plan

    High-rise buildings use voice communication systems or alarm notification appliances consistent with the building's fire safety plan to notify occupants.