← All PCR Flashcard Decks

Thermal Cycling Parameters & Optimization Flashcards

7 cards from real PCR practice questions. Tap to flip, then mark Knew It or Still Learning — missed cards come back until you master them.

Read the first 7 Thermal Cycling Parameters & Optimization flashcards as text
  1. A PCR run produces several nonspecific bands in addition to the target. Which thermal cycling adjustment should be tried first?

    Answer: Increase the annealing temperature in 2-3°C steps

    A higher annealing temperature increases stringency, so primers bind less often to partially matched sites.

  2. In touchdown PCR, how is the annealing temperature programmed?

    Answer: Started above the primer Tm and lowered by about 0.5-1°C per cycle

    Early high-stringency cycles favor the specific product, which then outcompetes nonspecific products in later cycles.

  3. What is the main advantage of a gradient thermal cycler during assay optimization?

    Answer: It tests a range of annealing temperatures across the block in one run

    A gradient block holds different columns at different temperatures, so the best annealing temperature can be found in one experiment.

  4. A template has 72% GC content and gives weak or no amplification. Which change is most likely to help?

    Answer: Raise the denaturation temperature or time and add DMSO or betaine

    GC-rich DNA has stronger strand pairing and secondary structure, so it needs harsher denaturation and helper additives.

  5. Using standard Taq polymerase, about how long should the extension step be for a 3 kb amplicon?

    Answer: About 3 minutes

    The usual rule for Taq is about 1 minute of extension per kilobase of product.

  6. Besides finishing incomplete products, what is a key benefit of a 5-10 minute final extension at 72°C when using Taq?

    Answer: It adds 3' A-overhangs needed for TA cloning

    Taq's terminal transferase activity adds a single 3' adenine, and a long final extension lets more products get this overhang.

  7. What is a common result of running too many cycles (e.g., 40-45) in endpoint PCR?

    Answer: Smearing and buildup of nonspecific products after the plateau

    Once reagents run low, extra cycles mostly amplify mispriming products and artifacts, which shows up as smears.

How this page was made: written with AI tools and published by Nathan Beja, founder of Practice Test Geeks, who is responsible for its content. We have not yet matched this exam's facts to an official source, so confirm fees, dates and rules with the exam body. Not reviewed by a subject-matter expert. Editorial policy