Electrical Hazards & Power Line Safety Flashcards
21 cards from real OSHA practice questions. Tap to flip, then mark Knew It or Still Learning — missed cards come back until you master them.
Read the first 20 Electrical Hazards & Power Line Safety flashcards as text
What is the minimum safe approach distance required by OSHA for crane operations near power lines energized at 50 kV or less?
Answer: 10 feet
OSHA 29 CFR 1926.1408 requires a minimum clearance of 10 feet for power lines energized up to 50 kV.
Before beginning crane operations near overhead power lines, what must the crane operator or employer determine first?
Answer: The voltage of the power lines
The voltage must be determined first because minimum approach distances are calculated based on the power line's voltage level.
If a crane boom accidentally contacts an energized overhead power line, what should the crane operator do immediately?
Answer: Stay in the cab and call for emergency help
The crane cab acts as a Faraday cage; exiting creates a path for current through the operator's body to ground, so staying inside is safer until power is deenergized.
Which OSHA standard governs crane and derrick operations in construction, including power line safety requirements?
Answer: 29 CFR 1926.1400 (Subpart CC)
29 CFR 1926.1400 (Subpart CC), effective 2010, is the comprehensive OSHA standard governing cranes and derricks in construction including electrical hazard requirements.
What minimum clearance distance does OSHA require when crane operations are conducted near power lines energized between 350 kV and 1,000 kV?
Answer: 35 feet
OSHA 1926.1408 requires a minimum approach distance of 35 feet for power lines energized between 350 kV and 1,000 kV.
Which device can be installed on a crane to warn the operator when the equipment is approaching an energized power line?
Answer: Proximity alarm (warning device)
A proximity alarm (also called a proximity warning device) alerts the operator with an audible or visual signal when the crane is nearing the power line danger zone.
If the voltage of nearby overhead power lines cannot be determined, what minimum clearance distance must be maintained during crane operations?
Answer: 20 feet
OSHA 1926.1408(b) requires a minimum clearance of 20 feet when the voltage cannot be determined, to account for uncertainty.
Under OSHA 1926.1408, who is responsible for notifying the utility company before crane work begins near overhead power lines?
Answer: The employer or controlling entity
OSHA places the responsibility for contacting the utility owner/operator on the employer or controlling entity before crane operations begin near power lines.
What is the purpose of an 'encroachment prevention plan' during crane operations near power lines?
Answer: To establish procedures that prevent the crane from entering the power line danger zone
An encroachment prevention plan defines the methods, equipment, and procedures that will keep any part of the crane or load from entering the power line's minimum approach distance.
Under what condition may a crane operate closer than standard OSHA minimum approach distances to overhead power lines?
Answer: When the utility owner deenergizes and visibly grounds the lines
OSHA 1926.1408(d) permits reduced clearance only when the utility owner/operator has deenergized the power lines and visibly grounded them.
What does 'equipotential zone' mean in the context of crane electrical safety?
Answer: A protected area where all objects are at the same electrical potential, reducing shock risk
An equipotential zone is created by bonding and grounding all conductive objects so they share the same electrical potential, preventing current flow through workers.
Which of the following is NOT an acceptable primary safeguard against power line hazards during crane operations?
Answer: Relying solely on a proximity warning device
A proximity warning device alone is insufficient; OSHA requires it to be used in combination with other controls such as insulating barriers or deenergized lines.
What should a signal person do immediately if a crane load begins to drift toward an overhead power line during a pick?
Answer: Immediately give the emergency stop signal
At any sign of imminent encroachment on a power line, the signal person must immediately give the stop signal so all crane movement ceases.
When a crane must operate within a power line's danger zone, OSHA requires that a dedicated spotter be assigned to watch for what?
Answer: The crane's proximity to the energized power lines at all times
OSHA requires a dedicated spotter whose sole responsibility is monitoring the distance between the crane and energized power lines during all movements in the danger zone.
What must occur before anyone on the ground approaches or touches a crane that has made contact with an energized overhead power line?
Answer: The utility company must deenergize and confirm the line is safe
No ground personnel should approach until the power company has deenergized the line and confirmed it is safe, because ground current and step potential remain hazards until then.
What is 'step potential' in the context of crane electrical safety?
Answer: The voltage difference between two ground points that can drive current through a person's body from foot to foot
Step potential is the voltage gradient across the ground near an energized contact point that can cause lethal current to flow up one leg and down the other.
The minimum approach distances listed in OSHA's power line safety tables are determined primarily by which factor?
Answer: The voltage level of the power line
Minimum approach distances are voltage-dependent because higher voltage creates a larger arc-flash zone and requires more clearance to prevent electrical contact.
What does OSHA 1926.1408 require when power line voltage information cannot be obtained before crane operations?
Answer: Maintain at least 20 feet of clearance from the lines
When voltage cannot be determined, OSHA mandates a conservative default minimum clearance of 20 feet to account for the uncertainty.
Which practice best protects a crane operator from 'touch potential' hazards if the crane contacts an energized power line?
Answer: Remaining inside the cab without touching external metal surfaces
Staying inside the cab avoids bridging the crane's energized body to ground through the operator's body; touching external metal while also touching the ground or cab floor creates a lethal path.
Under OSHA 1926.1408, what assessment must be completed before lifting operations begin in any work zone containing overhead power lines?
Answer: A determination must be made whether any part of equipment or load could enter the minimum approach distance during operations
OSHA requires a pre-operation assessment to determine if the equipment, load, or rigging could encroach on the minimum approach distance at any point during the lift.
Written and edited by Nathan Beja, founder of Practice Test Geeks, with AI assistance. Exam facts are checked against the official sources linked below. Editorial policy
Sources & references
Exam facts on this page (fees, format, dates, passing scores) are checked against these official sources; the date is our last check. Editorial policy