Under OSHA 29 CFR 1926.405, what is the maximum allowable length for a temporary power cord on a construction site before a ground-fault circuit interrupter (GFCI) is required?
Answer: There is no length limit; GFCIs are always required for temporary wiring
OSHA requires GFCI protection on all 120-volt, single-phase, 15- and 20-ampere temporary wiring used on construction sites regardless of cord length.
According to OSHA's electrical safety standards, what is the minimum approach distance for a qualified electrical worker near exposed energized parts operating at 601 to 750 volts?
Answer: 2 feet 2 inches
OSHA Table S-5 in 29 CFR 1910.333 specifies a minimum approach distance of 2 feet 2 inches for voltages ranging from 601 to 750 volts.
What does OSHA require an employer to do before employees work on deenergized electrical equipment?
Answer: Implement lockout/tagout procedures per 29 CFR 1910.147
OSHA mandates lockout/tagout procedures under 29 CFR 1910.147 to ensure equipment is properly deenergized and cannot be accidentally reenergized.
Under OSHA 29 CFR 1926.416, which of the following is a required safety practice when working near overhead power lines on a construction site?
Answer: All equipment must maintain at least 10 feet of clearance from lines up to 50 kV
OSHA requires a minimum clearance of 10 feet from overhead power lines energized at up to 50 kV, with additional clearance for higher voltages.
According to OSHA, what color must the grounding conductor insulation be in a fixed electrical installation?
Answer: Green or green with yellow stripes
OSHA and the National Electrical Code require equipment grounding conductors to be identified by green insulation or green with one or more yellow stripes.
What is the primary purpose of an assured equipment grounding conductor program (AEGCP) under OSHA 29 CFR 1926.404?
Answer: To ensure the grounding path of cord sets and receptacles is continuously maintained
An AEGCP is an alternative to GFCI protection that ensures grounding continuity of equipment through regular testing and visual inspection.
Written and edited by Nathan Beja, founder of Practice Test Geeks, with AI assistance. Exam facts are checked against the official sources linked below. Editorial policy
Sources & references
Exam facts on this page (fees, format, dates, passing scores) are checked against these official sources; the date is our last check. Editorial policy
- cslb.ca.gov — Eligibility, fees, renewal · verified Nov 2026
- www2.myfloridalicense.com — Exam format, passing score, retake policy, score release, time limit, test delivery, test dates · verified Nov 2026
- ncbeec.org — Test delivery, fees, exam format, passing score, retake policy, score release, test dates, time limit · verified Nov 2026