Facts verified Oct 20, 2026 against U.S. Environmental Protection Agency. Dates that have passed are removed automatically.
| Item | Detail | Official source |
|---|---|---|
| Number of questions (Universal) | 100 questions | ecfr.gov |
| Passing score | 70% (closed-book); 84% for mail-in Type I | ecfr.gov |
| Validity | Does not expire | U.S. Environmental Protection Agency |
| Renewal | No recertification currently required | ecfr.gov |
| Delivery | Closed-book, proctored test through an EPA-approved certifying program (mail-in allowed for Type I only) | ecfr.gov |
| Eligibility | Required for technicians who service or dispose of refrigerant-containing equipment; supervised apprentices exempt | U.S. Environmental Protection Agency |
| Score release | Within 30 days of the test | ecfr.gov |
Facts verified Oct 20, 2026 against U.S. Environmental Protection Agency. Dates that have passed are removed automatically. Practice with the free HVAC - Heating, Ventilation, and Air Conditioning practice test on PracticeTestGeeks (450+ questions with answer explanations).
Try these questions from our free HVAC - Heating, Ventilation, and Air Conditioning practice tests. The correct answer and an explanation follow each question.
Which component in a ductless mini-split system is responsible for reversing refrigerant flow to switch between heating and cooling modes?
Answer: B. Reversing valve
The reversing (or four-way) valve redirects refrigerant flow to switch the system between heating and cooling operation.
Which commercial HVAC system component is responsible for distributing conditioned air to specific zones based on thermostat demand?
Answer: B. VAV terminal box
VAV terminal boxes modulate airflow to individual zones in response to zone thermostat signals, providing precise temperature control.
In a variable air volume (VAV) air handler system, what component modulates airflow to different zones?
Answer: A. Zone dampers controlled by a central DDC controller
VAV systems use motorized zone dampers controlled by a Direct Digital Control (DDC) system to modulate airflow to each zone based on its thermostat demand.
What is the 'dual manifold' gauge technique for checking a system with two circuits (as in some commercial units)?
Answer: B. Connecting separate manifold gauge sets to each independent refrigerant circuit to compare pressures and diagnose imbalances
Some commercial units have two independent refrigerant circuits (two compressors, two coils). Using a separate gauge set on each circuit allows direct comparison of circuit pressures to identify if one circuit is underperforming, making multi-circuit diagnostics more efficient.