Fetal Cardiac Anatomy & Development Flashcards
7 cards from real FE practice questions. Tap to flip, then mark Knew It or Still Learning — missed cards come back until you master them.
Read the first 7 Fetal Cardiac Anatomy & Development flashcards as text
Which cardiac defect results from failure of the aortopulmonary septum to spiral normally?
Answer: D-transposition of the great arteries
D-transposition results when the aortopulmonary septum divides the truncus straight rather than spiraling, placing the aorta anterior and rightward over the right ventricle.
By what gestational age can the foramen ovale normally be visualized on fetal echocardiography?
Answer: 14–16 weeks
The foramen ovale and its flap (septum primum) are typically identifiable by 14–16 weeks using transvaginal or transabdominal echocardiography.
The moderator band is a characteristic trabecular structure found in which cardiac chamber?
Answer: Right ventricle
The moderator band is a muscular trabeculation in the right ventricle that carries part of the right bundle branch and helps identify the morphologic right ventricle.
In fetal circulation, what approximate percentage of combined ventricular output is directed through the ductus arteriosus?
Answer: 50–60%
Approximately 50–60% of combined cardiac output crosses the ductus arteriosus because fetal pulmonary vascular resistance is high and very little blood enters the lung circulation.
Which embryonic structure is the origin of the sinus node and contributes to the superior vena cava?
Answer: Sinus venosus
The sinus venosus, the most caudal part of the primitive heart tube, gives rise to the sinus node, the coronary sinus, and incorporates into the posterior right atrium.
Which view best demonstrates the relationship of the pulmonary veins to the left atrium in fetal echocardiography?
Answer: Four-chamber view with posterior angulation
Angling the transducer posteriorly from the four-chamber view allows visualization of pulmonary vein insertion into the posterior left atrium.
What is the normal cardiothoracic ratio (heart area to chest area) in the fetus?
Answer: 0.35–0.60
The normal fetal cardiothoracic ratio ranges from approximately 0.35 to 0.60; values above 0.60 suggest cardiomegaly.
How this page was made: written with AI tools and published by Nathan Beja, founder of Practice Test Geeks, who is responsible for its content. Exam facts are checked against the official sources listed below. Not reviewed by a subject-matter expert. Editorial policy
Sources & references
Exam facts on this page (fees, format, dates, passing scores) are checked against these official sources; the date is our last check. Editorial policy
- inteleos.org — Eligibility, exam format, passing score, retake policy, time limit, fees, test delivery · verified Oct 2026