  1. A patient with a transtibial amputation using a vacuum-assisted socket suspension (VASS) reports that the vacuum alarm triggers frequently during activity. The clinician should first check:

    Answer: Socket fit and liner integrity for air leaks

    Frequent vacuum alarms indicate air is entering the system, most commonly due to a compromised liner seal, liner tears, or an ill-fitting socket.

  2. When fabricating a custom AFO for a patient with mild spastic equinovarus, the trim lines should be:

    Answer: Posterior to the malleoli to provide maximum rigidity

    Posterior trim lines increase the rigidity of the AFO, providing necessary mediolateral stability and tone management for equinovarus deformity.

  3. During assessment for a new transfemoral prosthesis, the clinician measures the patient's residual limb and notes a circumference decrease of 2 cm proximally since the last visit. This most likely indicates:

    Answer: Significant volume loss requiring socket modification or replacement

    A 2 cm circumference decrease proximally suggests significant residual limb volume loss, which compromises socket fit and requires socket modification or replacement.

  4. Which combination of features characterizes an ischial containment socket (ICS) for a transfemoral amputation?

    Answer: Narrow ML dimension with the ischium contained inside the socket walls

    The ICS features a narrow mediolateral dimension that captures the ischium inside the socket, improving femoral adduction and proximal control.

  5. A pediatric patient with myelomeningocele at the L4 level presents for orthotic fitting. The expected motor function preserved includes:

    Answer: Hip flexion, knee extension, and partial foot dorsiflexion

    L4 sparing preserves hip flexors, quadriceps (knee extension), and partial tibialis anterior function, giving dorsiflexion and some medial foot control.

  6. A prosthetist notes that a patient's new exoskeletal (crustacean) prosthesis is cosmetically unacceptable due to visible misalignment of the pylon. In an endoskeletal (modular) system, this is addressed by:

    Answer: Adjusting the alignment at the modular pyramid connector and replacing the soft cover

    Endoskeletal systems allow alignment changes at the modular pyramid without full reconstruction; the soft cosmetic cover is then trimmed or replaced to match.

  7. Which clinical finding during a static prosthetic alignment check for a transtibial amputee indicates that the foot is set in excessive toe-out?

    Answer: The prosthetic limb abducts away from the midline when viewed from the front

    Excessive toe-out in the foot placement causes the lower leg segment to angle laterally, creating apparent abduction of the prosthetic limb during stance.