Phlebotomy and Specimen Collection Flashcards
6 cards from real CCMA practice questions. Tap to flip, then mark Knew It or Still Learning — missed cards come back until you master them.
Read the first 6 Phlebotomy and Specimen Collection flashcards as text
A patient's potassium result comes back critically elevated at 6.8 mEq/L, but the patient has no symptoms and a repeat draw is ordered. The phlebotomist notices the original sample had visible hemolysis. Which pre-analytical error most likely caused the spurious hyperkalemia, and what is the correct corrective action?
Answer: Prolonged tourniquet application causing potassium to leak from RBCs; redraw without exceeding 1 minute of tourniquet time
Hemolysis releases intracellular potassium (which is roughly 23× higher inside RBCs than in plasma) into the serum, causing falsely elevated potassium levels. The most common cause of hemolysis during phlebotomy is a tourniquet left on for more than 1 minute, which causes mechanical stress on red cells and venous stasis. The correct corrective action is to redraw with tourniquet time limited to under 1 minute, using the proper gauge needle, and avoiding excessive aspiration force.
When performing a neonatal heel stick for a PKU screening card, the phlebotomist fills the first circle but the blood flow slows significantly. What is the MOST appropriate next action?
Answer: Warm the heel with a warm compress for 3–5 minutes, then allow passive blood flow
Re-warming the heel (ideally with a warm, moist compress at no more than 42°C for 3–5 minutes) increases local blood flow by vasodilation and is the correct technique when flow slows. Squeezing or 'milking' the heel causes tissue fluid dilution of the specimen, which will invalidate metabolite concentrations on the screening card. A second puncture on the same site risks introducing the same dilution artifact, and switching heels unnecessarily causes additional pain and trauma to the neonate.
A phlebotomist is collecting a timed 24-hour urine specimen for creatinine clearance. The patient calls the lab after 8 hours to say they accidentally discarded one voiding. What is the correct course of action?
Answer: Instruct the patient to discard the entire collection, restart the 24-hour period from the next void, and void at the new start time without saving
A 24-hour urine collection must be complete to be accurate. Any missed void renders the entire collection invalid because creatinine clearance is calculated using the total urine volume over exactly 24 hours. The correct protocol is to discard the existing incomplete collection and restart: the patient voids at the start time (discarding that first void to empty the bladder), then saves all subsequent voids for the next 24 hours, ending with a final void at the 24-hour mark. Extrapolation or correction factors are not valid clinical practices for timed urine collections.
A patient on warfarin therapy has a PT/INR drawn in a 2.7 mL sodium citrate (light blue top) tube, but only 1.8 mL of blood was collected. The tech calls the phlebotomist to redraw. Why is an underfilled citrate tube a critical pre-analytical error for coagulation studies?
Answer: The excess citrate relative to blood volume over-anticoagulates the plasma, falsely prolonging clotting times
Sodium citrate works by chelating (binding) calcium ions to prevent coagulation. The required blood-to-citrate ratio is 9:1. When the tube is underfilled, there is proportionally more citrate relative to the blood volume, resulting in excess calcium chelation. When the laboratory recalcifies the plasma to run the PT/INR test, the excess citrate consumes more of the added calcium, requiring longer time for clot formation — producing falsely prolonged results. This is especially dangerous for a patient on warfarin, as it could lead to underdosing.
While performing a venipuncture, the phlebotomist inserts the needle and pulls back the syringe plunger but gets no blood flow. The needle bevel appears to be against the vein wall. Which corrective technique should be attempted FIRST before withdrawing the needle?
Answer: Rotate the needle 180° to reposition the bevel away from the vein wall
When the needle bevel is flush against the vein wall, it occludes blood entry. The first corrective maneuver is a slight 180° rotation of the needle, which repositions the bevel opening away from the wall and into the lumen, often restoring blood flow without requiring needle withdrawal. Advancing the needle further risks a through-puncture (penetrating the posterior vein wall). Increasing suction force risks collapsing the vein. Withdrawing and redirecting is a valid option only if the rotation fails, as it causes additional trauma.
A phlebotomist is collecting blood cultures from a febrile patient with a suspected central line-associated bloodstream infection (CLABSI). Per IDSA guidelines, what is the correct collection strategy to distinguish CLABSI from peripheral bacteremia?
Answer: Draw one set from the central line and one set from a peripheral venipuncture site simultaneously, and document the draw times
To diagnose CLABSI, the IDSA recommends paired blood cultures: one set drawn through the central venous catheter and one set drawn from a peripheral vein simultaneously (or within minutes of each other), with precise time-of-draw documentation for each. The laboratory then uses differential time to positivity (DTP): if the central line culture turns positive ≥2 hours before the peripheral culture, it is diagnostic of CLABSI. Drawing only from the central line cannot distinguish infection from colonization, and drawing all sets peripherally would miss the central line source entirely.
Written and edited by Nathan Beja, founder of Practice Test Geeks, with AI assistance. Exam facts are checked against the official sources linked below. Editorial policy
Sources & references
Exam facts on this page (fees, format, dates, passing scores) are checked against these official sources; the date is our last check. Editorial policy
- nhanow.com — Renewal, eligibility, passing score, retake fee, score release, score validity, time limit, test delivery · verified Nov 2026