Phlebotomy and Specimen Collection Flashcards
6 cards from real CCMA practice questions. Tap to flip, then mark Knew It or Still Learning — missed cards come back until you master them.
Read the first 6 Phlebotomy and Specimen Collection flashcards as text
A patient has severely compromised veins bilaterally due to chemotherapy. The nurse informs you that a PICC line is in the left arm. Which is the most appropriate phlebotomy action?
Answer: Perform a capillary puncture on the fingertip of the right hand
Phlebotomists are not qualified to access PICC lines — that requires a nurse or infusion specialist. Drawing distal to a PICC line risks diluted or contaminated results. A femoral draw is an invasive last resort requiring physician involvement. A capillary puncture on the right hand (opposite side from the PICC) is within phlebotomy scope and avoids compromised sites.
You are collecting a stat lactic acid level. The tube is filled, but you realize the specimen sat unprocessed at room temperature for 45 minutes before being sent to the lab. What is the expected impact on this result?
Answer: The lactic acid level will be falsely elevated because glycolysis continues in red blood cells ex vivo
Lactic acid is highly time-sensitive. Red blood cells continue glycolysis after collection, generating lactate ex vivo. If not chilled and processed within 15–30 minutes, lactic acid levels rise falsely. Proper handling requires immediate mixing, placing on ice, and processing within 15 minutes. Gray-top (sodium fluoride) tubes inhibit glycolysis for glucose but are NOT standard for lactic acid collection.
During venipuncture, blood initially flows into the tube but then stops before the tube is full. The needle appears correctly placed by visual inspection. What is the MOST likely cause and appropriate response?
Answer: The tube vacuum has been compromised; activate a new tube without moving the needle
When blood initially flows then stops, the most common cause is tube vacuum failure (a defective or pre-expired tube). The correct response is to swap in a new tube without moving the needle. Vein collapse from over-vacuum presents differently and may require a smaller tube, but the first troubleshooting step is always to change the tube. Releasing the tourniquet addresses hemoconcentration, not flow stoppage.
A laboratory test requires a 24-hour urine collection. The patient calls on hour 18 stating they accidentally discarded one void. What is the correct instruction?
Answer: Restart the entire 24-hour collection immediately, beginning with a discarded void
A 24-hour urine collection is invalid if any void is missed — even one discarded specimen breaks the collection protocol. The patient must start over with a fresh container and a new 24-hour clock, beginning by voiding and discarding that first specimen (to clear the bladder), then collecting all subsequent voids for the next full 24 hours. Submitting a partial collection with an 'adjusted' window is not an accepted laboratory practice for this test.
Which of the following represents the correct order of draw when collecting the following tubes simultaneously: light blue (sodium citrate), gold SST (serum separator), lavender (EDTA), and green (lithium heparin)?
Answer: Light blue → gold SST → green → lavender
Per CLSI guidelines, the correct order of draw for these tubes is: (1) blood cultures (not present here), (2) sodium citrate (light blue) — coagulation tests require no additive carryover, (3) SST/serum tubes (gold) — clot activator/gel, (4) heparin (green) — anticoagulant, (5) EDTA (lavender) — strongest chelating anticoagulant, (6) glycolytic inhibitors (gray). Lavender comes after green because EDTA carryover into heparin tubes would chelate calcium and falsely alter results less critically than the reverse.
A patient's potassium result comes back critically elevated at 6.8 mEq/L, but the patient is asymptomatic with no clinical signs of hyperkalemia. The physician suspects a laboratory artifact. Which pre-analytical error is MOST likely responsible?
Answer: Mechanical hemolysis caused by using too small a gauge needle or excessive aspiration force
Mechanical hemolysis releases intracellular potassium from red blood cells into the serum/plasma, causing a falsely elevated potassium result. This is the most common pre-analytical cause of pseudohyperkalemia. Using a needle smaller than 23 gauge, pulling a syringe plunger too forcefully, or expelling blood through a needle into a tube creates turbulence that lyses RBCs. Drawing near a saline IV dilutes electrolytes (falsely lowering potassium, not raising it). EDTA carryover would affect calcium and coagulation results. Incomplete clotting causes sample rejection but not isolated potassium elevation.
Written and edited by Nathan Beja, founder of Practice Test Geeks, with AI assistance. Exam facts are checked against the official sources linked below. Editorial policy
Sources & references
Exam facts on this page (fees, format, dates, passing scores) are checked against these official sources; the date is our last check. Editorial policy
- nhanow.com — Renewal, eligibility, passing score, retake fee, score release, score validity, time limit, test delivery · verified Nov 2026