Infection Control and Sterilization Flashcards
6 cards from real CCMA practice questions. Tap to flip, then mark Knew It or Still Learning — missed cards come back until you master them.
Read the first 6 Infection Control and Sterilization flashcards as text
A medical assistant runs a steam autoclave cycle and laterfinds that the biological indicator (BI) vial containing Geobacillus stearothermophilus spores turned yellow after incubation, while the control vial also turned yellow. What is the correct interpretation and required action?
Answer: The sterilizer failed because spores survived; the load must not be used and the sterilizer taken out of service until the cause is resolved
A yellow color change in a spore BI indicates the spores survived and metabolized, meaning the sterilization cycle failed. The control vial (unprocessed) is supposed to turn yellow, confirming the spores were viable and incubation worked. A passing processed vial should remain purple/unchanged. Because the processed vial turned yellow, sterilization failed: the load cannot be released, and the sterilizer must be taken out of service and the failure investigated (and often prior loads recalled).
A provider needs a semicritical flexible endoscope reprocessed between patients but the facility has no time for the full ethylene oxide cycle. According to the Spaulding classification, what is the MINIMUM acceptable level of reprocessing for a semicritical device that contacts mucous membranes but not sterile tissue?
Answer: High-level disinfection after thorough cleaning
Under the Spaulding classification, semicritical items contact mucous membranes or non-intact skin and require, at minimum, high-level disinfection (after thorough cleaning) — which kills all microorganisms except large numbers of bacterial spores. Sterilization is ideal but not the required minimum. Quaternary ammonium (low-level) and alcohol immersion are insufficient for semicritical devices.
During instrument reprocessing, a medical assistant is deciding the correct order of steps for a heavily soiled surgical clamp with a hinged joint. Which sequence is correct and why does the first step matter most?
Answer: Clean/decontaminate first, then sterilize, because organic debris (bioburden) shields microorganisms from the sterilant
Instruments must always be cleaned/decontaminated BEFORE sterilization. Organic material such as blood, tissue, and other bioburden physically shields microorganisms from contact with the sterilant, so residual debris can prevent sterilization from being effective. Hinged instruments must be opened and scrubbed in the joint. Sterilizing dirty instruments and letting protein fix (as alcohol would) both defeat the process.
A medical assistant sets up a sterile field and opens the outer wrap of a sterile pack. Which of the following is the SUBTLEST breach of sterile technique that would still contaminate the field?
Answer: The MA reaches over the sterile field to drop a sterile item onto its center
Reaching OVER a sterile field contaminates it because non-sterile sleeves/arms pass above the sterile surface and shed contaminants onto it — this is a commonly overlooked breach. The other options are actually correct technique: a 1-inch (here 1.5-inch) perimeter border IS considered non-sterile, the sterile surface must be kept at or above waist level, and the far flap of the wrap should be opened first (opening the near flap first would require reaching over the field).
A medical assistant sustains a needlestick from a hollow-bore needle used on a patient with unknown bloodborne status. Under OSHA's Bloodborne Pathogens Standard, which action reflects the correct immediate and administrative response?
Answer: Wash the area with soap and water, report the exposure immediately, and ensure a confidential post-exposure medical evaluation is documented
OSHA requires that a percutaneous exposure be washed with soap and water (mucous membranes flushed with water) and reported immediately so a confidential post-exposure evaluation and follow-up — including source testing when possible and timely prophylaxis decisions — can be provided at no cost to the employee and documented in the sharps injury log. Bleach/caustic agents on the wound and squeezing tissue are not recommended, and prophylaxis decisions cannot wait for confirmed source status.
A load of wrapped instruments is removed from the autoclave. The external chemical indicator tape has changed color, but the MA questions whether this truly confirms sterility. What is the correct understanding of what the chemical indicator tape demonstrates?
Answer: It confirms only that the package was exposed to a sterilization condition (e.g., heat), not that sterility was achieved
A chemical indicator (like autoclave tape) only verifies that the package was EXPOSED to certain sterilization conditions such as heat — it distinguishes processed from unprocessed packs. It does NOT prove that sterilization was actually achieved. Only a biological indicator (spore test) confirms that conditions were sufficient to kill microorganisms, so chemical indicators cannot substitute for spore testing.
Written and edited by Nathan Beja, founder of Practice Test Geeks, with AI assistance. Exam facts are checked against the official sources linked below. Editorial policy