← All CCMA Flashcard Decks

EKG Administration Flashcards

6 cards from real CCMA practice questions. Tap to flip, then mark Knew It or Still Learning — missed cards come back until you master them.

Read the first 6 EKG Administration flashcards as text
  1. While performing a 12-lead EKG on a patient with dextrocardia, the medical assistant should make which modification to obtain an accurate tracing?

    Answer: Reverse the arm limb leads and place precordial leads V1–V6 in mirror-image positions across the right chest

    In dextrocardia, the heart is positioned on the right side of the chest. To obtain a clinically meaningful tracing, both the arm (limb) electrodes are reversed AND the precordial leads are placed in mirror-image positions on the right side of the chest (V1 in the 4th intercostal space at the left sternal border becomes V2's usual position, and V3R–V6R continue across the right chest). Simply reversing arm leads or only moving chest leads would produce a partially inaccurate recording.

  2. A medical assistant records an EKG that shows a wandering baseline only in leads I, II, and III, while the precordial leads appear clean. Which is the MOST likely source of the artifact?

    Answer: Poor electrode contact or patient movement affecting a limb electrode

    Leads I, II, and III are all derived from the limb electrodes (RA, LA, LL). If artifact appears only in these leads while the chest leads are clean, the problem traces back to a limb electrode — commonly poor skin contact, dried gel, lotion on the skin, or limb movement. AC (60-cycle) interference and somatic tremor typically affect all leads, and a V3 wire problem would affect only V3.

  3. During a treadmill stress test, the patient's systolic blood pressure drops from 148 mmHg to 122 mmHg as the workload increases, and the patient reports feeling lightheaded. What is the medical assistant's BEST immediate action?

    Answer: Alert the provider immediately, as exertional hypotension is an indication to stop the test

    A drop in systolic blood pressure of 10 mmHg or more with increasing workload (exertional hypotension), especially when accompanied by symptoms like lightheadedness, is an absolute indication to terminate a stress test — it can signal severe ischemia or left ventricular dysfunction. The MA must notify the supervising provider immediately rather than continue or merely adjust the pace.

  4. An EKG tracing shows regular P waves at a rate of 84/min and regular QRS complexes at a rate of 38/min, with no consistent relationship between them. The QRS complexes are wide. The medical assistant should recognize this pattern and respond how?

    Answer: Recognize third-degree (complete) AV block and notify the provider immediately while staying with the patient

    Independent atrial and ventricular rates with no relationship between P waves and QRS complexes (AV dissociation), a slow wide-complex escape rhythm, and regular P waves at a normal rate is the classic picture of third-degree (complete) heart block. This is a potentially life-threatening rhythm — the MA should stay with the patient and notify the provider immediately, as the patient may need pacing.

  5. A patient with a large left mastectomy scar and a PICC line in the left arm requires a 12-lead EKG. The tissue under the standard V4–V6 positions is scarred and irregular. Which approach reflects proper technique?

    Answer: Place electrodes as close as possible to standard anatomical landmarks on intact skin and document any modified positions on the tracing

    When standard sites are compromised by scar tissue, dressings, or devices, the correct practice is to place electrodes as close as possible to the correct anatomical landmarks on viable skin and clearly document any deviations so the interpreting provider can account for altered waveform morphology. Skipping leads, moving them undocumented, or shifting all leads arbitrarily compromises the diagnostic value of the tracing.

  6. A Holter monitor is returned after 24 hours, and the scanned data shows the recording stopped 6 hours in. The patient's diary notes they showered that morning. The patient also reports their symptoms (palpitations) occurred on the second day, after the recording had stopped. What is the MOST appropriate course of action?

    Answer: Re-educate the patient on avoiding water exposure and arrange a repeat monitoring period, since the symptomatic period was not captured

    The purpose of ambulatory (Holter) monitoring is to correlate the patient's symptoms with the cardiac rhythm at the time they occur. Because the recording failed (likely due to water damage from showering) before the symptomatic episode, the study is non-diagnostic and must be repeated — along with re-education on keeping the device dry. Six hours of asymptomatic data cannot rule out an arrhythmia, and a single 12-lead EKG captures only seconds of rhythm.

Written and edited by , founder of Practice Test Geeks, with AI assistance. Exam facts are checked against the official sources linked below. Editorial policy

Sources & references

Exam facts on this page (fees, format, dates, passing scores) are checked against these official sources; the date is our last check. Editorial policy

  1. nhanow.com — Renewal, eligibility, passing score, retake fee, score release, score validity, time limit, test delivery · verified Nov 2026