EKG Administration Flashcards

6 cards from real CCMA practice questions. Tap to flip, then mark Knew It or Still Learning — missed cards come back until you master them.

Read the first 6 EKG Administration flashcards as text
  1. While performing a 12-lead EKG on a patient with dextrocardia, the medical assistant is instructed to obtain a tracing that accurately reflects the heart's electrical activity. Which modification is correct?

    Answer: Reverse the arm electrodes and place the precordial leads in mirror-image positions across the right chest

    In dextrocardia, the heart is located on the right side of the chest. To obtain an accurate tracing, the right and left arm electrodes are reversed AND the precordial (chest) leads V1–V6 are placed in mirror-image positions across the right side of the chest (sometimes labeled V1R–V6R). Reversing only the limb leads corrects the frontal plane but leaves the chest leads recording away from the heart, producing poor R-wave progression.

  2. A tracing shows a completely flat line in lead II only, while leads I and III appear normal. What is the most likely cause?

    Answer: A loose or disconnected electrode affecting the lead II circuit's recording, such as an internal cable fault between the right arm and left leg inputs

    A flat line in a single lead is virtually always a technical problem, not a cardiac one — asystole would appear in all leads. Lead II records the voltage between the right arm and left leg; a cable or connection fault in that specific circuit flatlines only that lead. Halved gain would shrink complexes in all leads, and somatic tremor produces erratic artifact, not a flat line.

  3. During a treadmill stress test, the CCMA notes the patient's systolic blood pressure has dropped 15 mmHg below the resting baseline despite increasing workload. What is the appropriate action?

    Answer: Alert the provider immediately, as exertional hypotension is an indication to terminate the test

    Systolic blood pressure should rise progressively with increasing exercise workload. A drop of 10 mmHg or more below baseline (especially with other signs of ischemia) suggests the heart cannot maintain cardiac output and is an absolute indication to stop the test. The medical assistant's role is to recognize this and alert the supervising provider immediately.

  4. A Holter monitor patient returns after 24 hours, and the scanned report shows long segments of missing data. During hookup review, which technique error most likely caused this?

    Answer: Electrodes were applied over unprepped, oily skin without abrading or clipping hair, causing intermittent signal loss

    Ambulatory monitoring depends on electrodes staying firmly adhered for 24–48 hours through movement and perspiration. Skin prep — cleansing with alcohol to remove oils, clipping hair, and lightly abrading the site — is essential; skipping it causes electrodes to loosen and the signal to drop out intermittently. Keeping a diary and continuing normal activity are both required parts of Holter monitoring, and placing torso electrodes over bone rather than large muscles actually reduces artifact.

  5. An EKG shows regular, sawtooth-shaped waves at approximately 300 per minute with a ventricular rate of 150 bpm. The provider asks the medical assistant to describe the rhythm for the chart note. Which description is accurate?

    Answer: Atrial flutter with 2:1 conduction

    Sawtooth flutter (F) waves at a rate near 300/min are the hallmark of atrial flutter. When the ventricular rate is exactly half the atrial rate (150 bpm), the AV node is conducting every second flutter wave — 2:1 conduction. Atrial fibrillation is irregularly irregular with no organized atrial waves, and ventricular tachycardia features wide QRS complexes, neither of which matches this description.

  6. The medical assistant must perform a 12-lead EKG on a patient with a left arm amputation above the elbow. What is the correct electrode placement per standard guidelines?

    Answer: Place the left arm electrode on the most distal available site of the residual limb, and place the right arm electrode at the equivalent level to keep the limb leads symmetric

    For amputees, the limb electrode is placed on the most distal portion of the remaining limb, and the contralateral electrode is moved to the same anatomical level so the two arm electrodes remain symmetric — asymmetric placement distorts the frontal-plane axis and limb-lead voltages. Omitting an electrode prevents the machine from calculating the limb leads at all, and moving only one electrode to the torso creates a modified (Mason-Likar-style) tracing that is not equivalent without adjusting its pair.