  1. A medical assistant is performing a venipuncture on a patient with a mastectomy on the left side and an active IV infusion in the right forearm. Which site selection is MOST appropriate?

    Answer: Right hand veins, distal to the IV, after asking the nurse to pause the infusion for 2 minutes and applying the tourniquet below the IV site

    Drawing from the mastectomy side risks lymphedema and inaccurate results and generally requires provider approval regardless of how long ago the surgery occurred. Drawing proximal (above) an active IV risks contamination with IV fluids. The best option is drawing distal to (below) the IV on the right side, ideally with the infusion paused for about 2 minutes and the tourniquet placed between the IV site and the draw site. Never draw above an active IV, and avoid the mastectomy side without explicit provider authorization.

  2. While performing a 12-lead ECG, the tracing shows a wandering baseline in leads I, II, and III only, while the precordial leads (V1–V6) appear clean. What is the MOST likely cause?

    Answer: Poor electrode contact or patient movement affecting the limb electrodes

    Leads I, II, and III are derived exclusively from the limb electrodes (RA, LA, LL). Artifact isolated to these leads points to a limb electrode problem — poor skin contact, lotion or hair interfering with adhesion, or limb movement. Sixty-cycle (AC) interference typically appears as uniform fuzzy thickening across all leads, and a faulty chest electrode would affect the corresponding V lead, not the limb leads.

  3. A patient's wound culture must be collected along with a wound cleansing and dressing change. In which order should the medical assistant expect these tasks to be performed?

    Answer: Collect the culture from the deep wound bed after removing surface exudate, then cleanse, then apply the new dressing

    A wound culture should sample viable tissue in the wound bed, not surface pus or old dressing exudate, which contain skin flora and dead organisms that can mislead treatment. Surface exudate is removed (typically with sterile saline, not antiseptic, which could kill the target organisms before collection), the swab is taken from the wound bed, and only afterward is the wound fully cleansed and redressed. Culturing after antiseptic cleansing can produce false-negative results.

  4. During a glucose tolerance test (OGTT), the patient vomits 20 minutes after drinking the glucose beverage. What is the CORRECT action for the medical assistant?

    Answer: Notify the provider and discontinue the test, since the glucose dose is no longer valid

    If a patient vomits shortly after ingesting the glucose load, the full dose has not been absorbed, and all subsequent timed values would be invalid. The test must be stopped and the provider notified; it is typically rescheduled for another day, sometimes with an antiemetic ordered beforehand. Re-dosing the same day is not acceptable because an unknown amount of the original load may have been absorbed, and continuing the draws would produce misleadingly low values.

  5. A provider orders a Mantoux tuberculin skin test. After injecting the PPD intradermally, the medical assistant observes that NO wheal formed at the site. What should the assistant do?

    Answer: Repeat the injection at a site at least 2 inches away from the original site

    A wheal (6–10 mm raised bleb) confirms the PPD was deposited intradermally. No wheal means the injection went too deep (subcutaneously), and the test will not be valid. The correct action is to repeat the test immediately at another site at least 2 inches away (or the other arm). Massaging the site is contraindicated as it disperses the antigen, and proceeding to schedule a reading would risk a false-negative result on an invalid test.

  6. A medical assistant is preparing to administer a vaccine drawn from a multi-dose vial and notices the vial was first punctured 35 days ago, per the date written on the label. The expiration date printed by the manufacturer is 8 months away. What should the assistant do?

    Answer: Discard the vial and draw from a new one, since most opened multi-dose vials expire 28 days after first puncture

    Once a multi-dose vial is punctured, the manufacturer's printed expiration date no longer applies. Per CDC and USP guidance, an opened multi-dose vial must generally be discarded 28 days after first puncture (unless the manufacturer specifies a different beyond-use date). At 35 days, this vial has exceeded its beyond-use date and must be discarded regardless of the printed expiration or storage conditions, due to the risk of contamination and loss of preservative effectiveness.