21 cards from real Air Conditioning Repair practice questions. Tap to flip, then mark Knew It or Still Learning โ€” missed cards come back until you master them.

Read the first 20 Refrigeration System Repair flashcards as text
  1. A technician measures suction pressure that is too high and discharge pressure that is too low. What is the most likely cause?

    Answer: Faulty compressor valves

    Faulty compressor valves (worn or leaking) allow high-pressure gas to bypass back to the suction side, raising suction pressure and lowering discharge pressure.

  2. Which refrigerant is classified as an A2L (mildly flammable) and is commonly used as a replacement for R-22 in new equipment?

    Answer: R-32

    R-32 is classified as A2L (mildly flammable) and is increasingly used in new equipment as an environmentally preferable alternative.

  3. When replacing a filter-drier on a refrigeration system, what is the correct procedure after installing the new drier?

    Answer: Pull a deep vacuum before recharging

    After replacing a filter-drier, a deep vacuum must be pulled to remove air and moisture before recharging with refrigerant.

  4. A refrigerant sight glass shows bubbles even though the system appears to have adequate charge. What could cause this besides low charge?

    Answer: Pressure drop across a restriction in the liquid line

    A restriction in the liquid line causes a pressure drop that can flash refrigerant into vapor, producing bubbles in the sight glass even with sufficient charge.

  5. What is the purpose of a suction line accumulator in a refrigeration system?

    Answer: Prevent liquid refrigerant from entering the compressor

    A suction line accumulator catches any liquid refrigerant before it can reach the compressor, protecting it from liquid slugging damage.

  6. A technician finds the compressor running but no cooling occurring and the refrigerant charge appears correct. The metering device is a TXV. What should be checked first?

    Answer: TXV bulb contact and charge

    A TXV with a lost bulb charge or poor bulb contact will stay closed, preventing refrigerant flow and causing a no-cooling condition.

  7. Which condition would cause a refrigeration system to short-cycle (compressor turns on and off rapidly)?

    Answer: Low refrigerant charge tripping the low-pressure switch

    A low refrigerant charge causes suction pressure to drop below the low-pressure switch cutout, cycling the compressor off, then on again repeatedly.

  8. What does a high subcooling reading combined with high discharge pressure most likely indicate?

    Answer: Non-condensables in the system

    Non-condensables such as air in the system raise discharge pressure and subcooling because they occupy condenser space without condensing.

  9. When recovering refrigerant from a system, the technician must use equipment certified to which standard?

    Answer: SAE J2788

    SAE J2788 certification is required for refrigerant recovery/recycling equipment used on motor vehicle AC systems; EPA Section 608 requires similar certification for stationary systems.

  10. A tech notices the evaporator coil is freezing up only at the inlet. What is the most likely cause?

    Answer: Metering device feeding too much refrigerant

    When the metering device feeds excessive refrigerant, it floods the evaporator inlet, causing ice formation at the entry point where liquid refrigerant accumulates.

  11. What is the minimum evacuation level (microns) typically required before recharging a residential air conditioning system?

    Answer: 500 microns

    Industry standard requires pulling the system down to 500 microns or below to ensure adequate moisture and air removal before charging.

  12. A compressor has a burnt motor winding. After replacing it, what additional step is critical before restarting?

    Answer: Flushing the system to remove acid and debris

    A burnt motor leaves acid contamination that must be flushed out and a liquid-line suction filter-drier installed to prevent damage to the new compressor.

  13. Which type of oil is used in systems charged with R-410A refrigerant?

    Answer: Polyol ester (POE) oil

    POE oil is required in R-410A systems because it is miscible with HFC refrigerants and properly lubricates the compressor throughout the system.

  14. What does a negative superheat reading at the evaporator outlet indicate?

    Answer: Liquid refrigerant is leaving the evaporator

    Negative superheat means the refrigerant temperature at the evaporator outlet is below saturation temperature, indicating liquid refrigerant is leaving the coil.

  15. A technician is diagnosing a system with low suction pressure, high superheat, and normal condenser performance. What is the most likely cause?

    Answer: Restricted or underfeeding metering device

    A restricted or underfeeding metering device starves the evaporator of refrigerant, causing low suction pressure and high superheat simultaneously.

  16. What is the purpose of a crankcase heater on a compressor?

    Answer: Prevent refrigerant from migrating into and diluting the compressor oil during off cycles

    A crankcase heater keeps the compressor warm during the off cycle to prevent refrigerant from migrating and mixing with the oil, which could cause slugging on startup.

  17. When using an electronic leak detector on an HFC system, which type of sensor is most appropriate?

    Answer: Infrared sensor

    Infrared sensors are highly accurate for HFC refrigerants and are not destroyed by exposure to refrigerant the way heated diode sensors can be.

  18. A system using a fixed orifice metering device shows high suction pressure in winter. What adjustment is typically required?

    Answer: Replace with a TXV

    Fixed orifice devices cannot modulate with changing conditions; replacing with a TXV allows proper refrigerant metering across varying outdoor temperatures.

  19. What symptom would a technician observe if the reversing valve on a heat pump is stuck in the heating position?

    Answer: No cooling in summer, heating works normally

    If the reversing valve is stuck in heating mode, the system will heat in both summer and winter, providing no cooling when switched to cooling mode.

  20. Which condition is indicated by oil streaks or staining around refrigerant line fittings and joints?

    Answer: Refrigerant and oil leak at that location

    Oil streaks at joints indicate refrigerant is leaking there, since refrigerant oil escapes along with refrigerant gas through any leak point.

Written and edited by , founder of Practice Test Geeks, with AI assistance. We have not yet matched this exam's facts to an official source, so confirm fees, dates and rules with the exam body. Editorial policy