Heat Load Calculations and System Sizing Flashcards

14 cards from real Air Conditioning Repair practice questions. Tap to flip, then mark Knew It or Still Learning โ€” missed cards come back until you master them.

Read the first 14 Heat Load Calculations and System Sizing flashcards as text
  1. What unit is commonly used to measure the cooling capacity of an air conditioning system?

    Answer: BTU/hr

    BTU/hr (British Thermal Units per hour) is the standard unit used to express the cooling capacity of air conditioning equipment on nameplates and specifications.

  2. How many BTU/hr are equivalent to one ton of refrigeration?

    Answer: 12,000

    One ton of refrigeration equals 12,000 BTU/hr, which originated from the amount of heat needed to melt one ton of ice in 24 hours.

  3. What is ACCA Manual J used for in the HVAC industry?

    Answer: Performing residential load calculations

    ACCA Manual J is the industry-standard method for calculating residential heating and cooling loads to properly size HVAC equipment.

  4. Which of the following factors does NOT significantly affect a building's cooling load?

    Answer: Interior wall paint color

    Interior paint color has a negligible effect on cooling load; exterior surface colors can affect solar absorptance, but interior colors do not meaningfully impact heat gain.

  5. What is the primary consequence of installing an oversized air conditioning system?

    Answer: Short cycling and poor humidity control

    An oversized system reaches the thermostat setpoint too quickly, causing it to short cycle and run for insufficient time to remove humidity from the air.

  6. What does the Sensible Heat Ratio (SHR) indicate about an air conditioning system?

    Answer: The proportion of total cooling capacity devoted to sensible versus latent heat removal

    SHR is the ratio of sensible cooling (temperature reduction) to total cooling capacity, indicating how much of the system's capacity is used for temperature versus humidity removal.

  7. What is the recommended method for sizing a replacement air conditioner when no prior load data is available?

    Answer: Perform a proper Manual J load calculation

    A proper Manual J load calculation is always the correct approach because existing equipment may have been incorrectly sized, and building conditions may have changed.

  8. What type of heat gain is caused by heat transferring through walls, roofs, and floors due to a temperature difference?

    Answer: Conductive heat gain

    Conductive heat gain occurs when heat flows through solid building materials from a warm exterior surface to a cooler interior, governed by the material's U-value and the temperature difference.

  9. In the northern hemisphere, windows facing which direction typically contribute the greatest solar heat gain during summer afternoons?

    Answer: West

    West-facing windows receive direct sunlight during the afternoon when outdoor temperatures are at their highest, resulting in the greatest peak solar heat gain.

  10. What does the latent heat load in an air conditioning system represent?

    Answer: Moisture that must be removed from the air

    Latent heat load is associated with moisture (water vapor) removal from the air; removing latent heat does not lower air temperature but reduces relative humidity.

  11. ASHRAE design outdoor conditions used in load calculations are based on which statistical criteria?

    Answer: A temperature exceeded only 1% of annual hours

    ASHRAE design conditions represent outdoor temperatures that are exceeded only 1% (or 2.5%) of all annual hours, providing a statistically reliable but not absolute worst-case design point.

  12. How does uncontrolled air infiltration affect a building's cooling load?

    Answer: It adds both sensible and latent load by introducing unconditioned outdoor air

    Infiltration introduces hot, humid outdoor air through gaps and cracks in the building envelope, adding both sensible heat (temperature) and latent load (moisture) that the AC system must handle.

  13. What is the primary purpose of an ACCA Manual D calculation?

    Answer: Designing and sizing the duct distribution system

    ACCA Manual D is the industry standard for residential duct system design, providing methods to size ducts so that the correct amount of conditioned air reaches each room.

  14. In a residential load calculation, what category includes heat generated by occupants, lighting, and household appliances?

    Answer: Internal heat gain

    Internal heat gain accounts for heat produced by sources inside the conditioned space, including people, lighting fixtures, and appliances such as ovens and electronics.

Written and edited by , founder of Practice Test Geeks, with AI assistance. We have not yet matched this exam's facts to an official source, so confirm fees, dates and rules with the exam body. Editorial policy