  1. What does EER (Energy Efficiency Ratio) measure in an air conditioning system?

    Answer: Cooling output in BTU/h divided by power input in watts at a single operating condition

    EER is the ratio of cooling capacity (BTU/h) to electrical power input (watts) measured at a specific set of conditions, such as 95°F outdoor and 80°F indoor.

  2. A residential AC system's SEER2 rating is used to measure what?

    Answer: Seasonal cooling efficiency over an entire cooling season under varied conditions

    SEER2 (Seasonal Energy Efficiency Ratio 2) measures average cooling efficiency across a full season under a range of temperature conditions using updated test procedures.

  3. What is subcooling in an air conditioning system and why is it measured?

    Answer: The degrees the liquid refrigerant is cooled below its condensing temperature, used to verify proper charge and condenser performance

    Subcooling measures how many degrees below its saturation point the liquid refrigerant has been cooled, and is used to confirm correct refrigerant charge and condenser effectiveness.

  4. Which EPA regulation governs the handling, recovery, and recycling of refrigerants used in AC systems in the United States?

    Answer: Section 608 of the Clean Air Act

    EPA Section 608 of the Clean Air Act establishes regulations for refrigerant handling, recovery, and technician certification requirements.

  5. What is the purpose of a hard-start kit installed on a compressor?

    Answer: To provide extra starting torque and reduce starting amperage draw to help the compressor start under difficult conditions

    A hard-start kit (start capacitor and relay) provides additional starting torque, helping compressors that struggle to start due to voltage fluctuations or high backpressure.

  6. When performing a maintenance inspection, a technician finds that the evaporator drain pan is filled with algae. What is the recommended corrective action?

    Answer: Clean the pan and treat it with condensate pan tablets or diluted bleach, then ensure the drain line flows freely

    Algae and slime in the condensate pan should be cleaned out and treated with biocide tablets or diluted bleach to prevent drain line clogs and microbial growth.