  1. What is the primary component of landfill gas (LFG) produced during anaerobic decomposition?

    Answer: Methane

    Methane (CH4) is the primary component of LFG, typically comprising 45–60% of the gas mixture produced by anaerobic microbial decomposition of organic waste.

  2. What does NSPS stand for in the context of EPA landfill gas regulations?

    Answer: New Source Performance Standards

    NSPS stands for New Source Performance Standards, established under the Clean Air Act (40 CFR Part 60, Subpart XXX) to regulate emissions from new MSW landfills.

  3. Under EPA regulations, MSW landfills above what design capacity threshold must install a gas collection and control system (GCCS) if NMOC emissions exceed 34 Mg/yr?

    Answer: 2.5 million Mg

    EPA requires MSW landfills with a design capacity of 2.5 million Mg or more that emit at least 34 Mg/yr of NMOC to install and operate a GCCS.

  4. What is the typical methane concentration range found in landfill gas?

    Answer: 40–60%

    Landfill gas typically contains 40–60% methane by volume, with most of the remainder being carbon dioxide and trace amounts of other gases.

  5. In an active LFG collection system, what is the primary function of the blower/vacuum pump unit?

    Answer: Create negative pressure to draw gas from extraction wells

    The blower creates a negative pressure (vacuum) in the collection pipes that draws landfill gas from the extraction wells toward the header system for control or utilization.

  6. What is the primary purpose of a knockout pot (condensate trap) installed in an LFG collection system?

    Answer: Remove moisture and liquid condensate from the gas stream

    A knockout pot separates and collects liquid condensate (water and leachate) that accumulates in collection pipes, preventing liquids from entering blowers or control equipment.

  7. Which trace gas in landfill gas is primarily responsible for odor complaints at and near landfill facilities?

    Answer: Hydrogen sulfide

    Hydrogen sulfide (H2S), though present in trace concentrations, has a very low odor threshold (detectable at <1 ppb) and is the main cause of rotten-egg odor complaints near landfills.