← All SACA Flashcard Decks

Safety Systems and Functional Safety Flashcards

7 cards from real SACA practice questions. Tap to flip, then mark Knew It or Still Learning — missed cards come back until you master them.

Read the first 7 Safety Systems and Functional Safety flashcards as text
  1. In safety system voting logic, what does a '1oo2' (one-out-of-two) architecture mean?

    Answer: Either one of two sensors detecting the hazard is sufficient to initiate a safety action

    A 1oo2 architecture initiates the safety function if either one of two sensors detects an abnormal condition, improving availability at the cost of potentially more spurious trips.

  2. Which IEC standard specifically addresses Safety Instrumented Systems (SIS) for the process industry sector?

    Answer: IEC 61511

    IEC 61511 is the process-industry sector application of IEC 61508, covering engineering and operation of SIS in oil, gas, and chemical plants.

  3. Probability of Failure on Demand (PFD) is used to measure:

    Answer: The likelihood a safety system fails to act when a safety demand occurs

    PFD quantifies the probability that a safety function will fail to perform its intended action when a demand occurs, and is used to verify that the required SIL target is met.

  4. The safety lifecycle concept in IEC 61508 requires that safety activities be performed:

    Answer: Throughout all phases from concept through decommissioning

    The IEC 61508 safety lifecycle is a cradle-to-grave approach encompassing concept, design, implementation, operation, maintenance, and decommissioning to ensure functional safety is maintained throughout.

  5. Per IEC 60204-1, Stop Category 0 on a machine is defined as:

    Answer: An immediate removal of power to the machine actuators

    Stop Category 0 is an uncontrolled stop achieved by immediately removing power (or interrupting energy) to the machine actuators, which is the default safe state for E-stop functions.

  6. What is a 'safe state' in the context of a Safety Instrumented Function (SIF)?

    Answer: A predefined condition where risk to personnel and equipment is reduced to an acceptable level

    The safe state is the predefined, stable condition to which a process or machine is brought when the SIF is activated, minimizing risk to personnel, equipment, and the environment.

  7. What is the key difference between a Safety Instrumented System (SIS) and a Basic Process Control System (BPCS)?

    Answer: A SIS is an independent protection layer that acts when the BPCS cannot keep the process safe

    The SIS is separate and independent from the BPCS; while the BPCS handles normal process control, the SIS acts as an independent safety layer that activates when the BPCS fails to prevent a hazardous condition.

Written and edited by , founder of Practice Test Geeks, with AI assistance. Exam facts are checked against the official sources linked below. Editorial policy

Sources & references

Exam facts on this page (fees, format, dates, passing scores) are checked against these official sources; the date is our last check. Editorial policy

  1. saca.org — Retake policy, score release, test delivery, eligibility · verified Nov 2026