  1. What is 'data historian' software in industrial automation, and what type of data does it store?

    Answer: A time-series database optimized for storing and retrieving high-frequency process variable data (tags) from SCADA and DCS systems

    A process historian is a specialized time-series database (OSIsoft PI, Aveva Historian, Ignition Historian) storing millions of process values (temperature, pressure, flow, motor current) with timestamps — enabling trend analysis, performance monitoring, and regulatory compliance.

  2. In IIoT architecture, what is the difference between 'telemetry' and 'command' message flows?

    Answer: Telemetry flows device-to-cloud (sensor data reporting); commands flow cloud-to-device (instructions to actuators or controllers)

    Telemetry = device → cloud: sensor readings, status, diagnostics. Commands = cloud → device: setpoint changes, start/stop, configuration updates. Separating these flows allows independent security policies and QoS settings for data vs. control.

  3. What is 'edge AI' inference in industrial automation, and what is its advantage over cloud-based AI inference?

    Answer: Running AI inference algorithms locally on edge hardware near the data source, enabling real-time decisions without cloud round-trip latency

    Edge AI inference runs trained neural network models on local hardware (NVIDIA Jetson, Intel NCS, edge PLCs), making predictions in milliseconds without requiring internet connectivity — enabling real-time defect detection, anomaly detection, and predictive maintenance at the machine.

  4. In IIoT security, what is a 'zero trust' network architecture approach?

    Answer: A security model where no device or user is automatically trusted based on network location — every access request requires authentication and authorization

    Zero trust abandons the 'trusted inside the firewall' assumption — every device, user, and application must prove identity and receive explicit authorization for each access, even within the plant network, minimizing the impact of a compromised device.

  5. What does 'SCADA' stand for and what is its primary function in industrial automation?

    Answer: Supervisory Control And Data Acquisition — provides high-level monitoring, data collection, and supervisory control over distributed industrial processes from a central location

    SCADA (Supervisory Control And Data Acquisition) systems provide centralized monitoring and control of distributed field devices (RTUs, PLCs) — collecting data, displaying process mimics, generating alarms, and allowing operators to issue high-level supervisory commands.

  6. In industrial IoT deployments, what is a 'protocol gateway' device used for?

    Answer: A device that translates between different industrial communication protocols, enabling legacy field devices to connect to modern IIoT platforms

    A protocol gateway (e.g., Moxa MGate, Anybus Communicator) translates between protocols — converting Modbus RTU from a legacy meter into MQTT for an IoT platform, or translating PROFIBUS DP into EtherNet/IP for a modern PLC, enabling heterogeneous system integration.