Troubleshooting & Diagnostics Flashcards
7 cards from real RRT practice questions. Tap to flip, then mark Knew It or Still Learning — missed cards come back until you master them.
Read the first 7 Troubleshooting & Diagnostics flashcards as text
A carpet shows light and dark patches that change appearance depending on viewing angle, but no fiber loss. What is the most likely diagnosis?
Answer: Pile reversal (shading)
Shading occurs when pile tufts lie in different directions, reflecting light differently.
A single tuft protrudes above the pile surface of a cut-pile carpet with no loop pulled. What is the correct repair?
Answer: Trim it level with the surrounding pile using scissors
Sprouting tufts should be clipped flush with the pile, never pulled, to avoid unraveling adjacent rows.
A technician wants to verify whether a concrete slab's moisture is causing glue-down carpet failure. Which test measures internal relative humidity in the slab?
Answer: In-situ RH probe test (ASTM F2170)
ASTM F2170 uses probes inserted into drilled holes to measure relative humidity inside the slab.
After pulling a single loop in a Berber carpet, a whole row unravels across the room. What is this failure called?
Answer: Zippering
Zippering is the run of a loop-pile row when a snag is pulled, common in level-loop Berbers.
Dark gray lines appear along baseboards and under doors in a carpeted home. What is the most likely cause?
Answer: Soil filtration from air passing through the carpet edges
Filtration soiling occurs when air flows through gaps under walls and doors, depositing airborne particles in the carpet.
A seam shows a raised ridge running its full length that appears to 'peak' upward. Which condition commonly causes seam peaking?
Answer: Overstretching across the seam and using too much hot-melt tape heat or bulk
Seam peaking is often caused by excess stretch pulling perpendicular to the seam combined with a stiff or improperly set seam tape.
A wall-to-wall carpet developed ripples several months after installation, and the installer used only a knee kicker. What is the most likely root cause?
Answer: Insufficient stretch because no power stretcher was used
Industry standards (CRI 105) require a power stretcher because a knee kicker alone cannot achieve proper tension, leading to later rippling.
Written and edited by Nathan Beja, founder of Practice Test Geeks, with AI assistance. Exam facts are checked against the official sources linked below. Editorial policy
Sources & references
Exam facts on this page (fees, format, dates, passing scores) are checked against these official sources; the date is our last check. Editorial policy
- iicrc.org — Test delivery, eligibility, fees, renewal, score release, test dates, retake fee, retake policy, passing score · verified Nov 2026