← All RRT Flashcard Decks

Troubleshooting & Diagnostics Flashcards

7 cards from real RRT practice questions. Tap to flip, then mark Knew It or Still Learning — missed cards come back until you master them.

Read the first 7 Troubleshooting & Diagnostics flashcards as text
  1. A carpet shows light and dark patches that change appearance depending on viewing angle, but no fiber loss. What is the most likely diagnosis?

    Answer: Pile reversal (shading)

    Shading occurs when pile tufts lie in different directions, reflecting light differently.

  2. A single tuft protrudes above the pile surface of a cut-pile carpet with no loop pulled. What is the correct repair?

    Answer: Trim it level with the surrounding pile using scissors

    Sprouting tufts should be clipped flush with the pile, never pulled, to avoid unraveling adjacent rows.

  3. A technician wants to verify whether a concrete slab's moisture is causing glue-down carpet failure. Which test measures internal relative humidity in the slab?

    Answer: In-situ RH probe test (ASTM F2170)

    ASTM F2170 uses probes inserted into drilled holes to measure relative humidity inside the slab.

  4. After pulling a single loop in a Berber carpet, a whole row unravels across the room. What is this failure called?

    Answer: Zippering

    Zippering is the run of a loop-pile row when a snag is pulled, common in level-loop Berbers.

  5. Dark gray lines appear along baseboards and under doors in a carpeted home. What is the most likely cause?

    Answer: Soil filtration from air passing through the carpet edges

    Filtration soiling occurs when air flows through gaps under walls and doors, depositing airborne particles in the carpet.

  6. A seam shows a raised ridge running its full length that appears to 'peak' upward. Which condition commonly causes seam peaking?

    Answer: Overstretching across the seam and using too much hot-melt tape heat or bulk

    Seam peaking is often caused by excess stretch pulling perpendicular to the seam combined with a stiff or improperly set seam tape.

  7. A wall-to-wall carpet developed ripples several months after installation, and the installer used only a knee kicker. What is the most likely root cause?

    Answer: Insufficient stretch because no power stretcher was used

    Industry standards (CRI 105) require a power stretcher because a knee kicker alone cannot achieve proper tension, leading to later rippling.

Written and edited by , founder of Practice Test Geeks, with AI assistance. Exam facts are checked against the official sources linked below. Editorial policy

Sources & references

Exam facts on this page (fees, format, dates, passing scores) are checked against these official sources; the date is our last check. Editorial policy

  1. iicrc.org — Test delivery, eligibility, fees, renewal, score release, test dates, retake fee, retake policy, passing score · verified Nov 2026