Corrosion Control and Cathodic Protection Flashcards
7 cards from real RMGA practice questions. Tap to flip, then mark Knew It or Still Learning — missed cards come back until you master them.
Read the first 7 Corrosion Control and Cathodic Protection flashcards as text
What is cathodic protection primarily used for in gas distribution systems?
Answer: To prevent external corrosion of buried metallic pipe
Cathodic protection is an electrochemical technique applied to the exterior of buried metallic pipelines to prevent soil-side corrosion.
What type of anode material is commonly used in impressed current cathodic protection systems?
Answer: Graphite or mixed metal oxide (MMO)
Graphite and mixed metal oxide (MMO) anodes are preferred for impressed current systems because of their extremely low consumption rate and long service life under high current output.
What is the minimum pipe-to-soil potential (vs. copper-copper sulfate electrode) indicating adequate cathodic protection per NACE SP0169?
Answer: -0.85 volts
A minimum potential of -0.85 volts (vs. CSE) is the widely accepted industry criterion for adequate cathodic protection of steel pipe per NACE SP0169.
In pipeline coating inspection, what does the term 'holiday' refer to?
Answer: A defect, void, or break in the pipeline's external coating
A holiday is a discontinuity or flaw in the protective coating that leaves bare metal exposed to the surrounding soil environment, requiring cathodic protection to compensate.
Which federal regulation governs cathodic protection requirements for natural gas distribution pipelines in the United States?
Answer: 49 CFR Part 192
49 CFR Part 192 (Transportation of Natural and Other Gas by Pipeline: Minimum Federal Safety Standards) establishes cathodic protection requirements for natural gas distribution and transmission systems.
What is the primary purpose of a test station installed on a buried gas pipeline?
Answer: To provide accessible connection points for measuring pipe-to-soil potential without excavation
Test stations bring lead wires from the pipe to the surface, allowing corrosion technicians to measure pipe-to-soil potential and other cathodic protection parameters at regular intervals without excavating.
What type of corrosion occurs when two dissimilar metals are electrically connected in the presence of an electrolyte?
Answer: Galvanic corrosion
Galvanic corrosion occurs due to the electrochemical potential difference between dissimilar metals, causing the more active (anodic) metal to corrode preferentially while the less active (cathodic) metal is protected.
How this page was made: written with AI tools and published by Nathan Beja, founder of Practice Test Geeks, who is responsible for its content. Exam facts are checked against the official sources listed below. Not reviewed by a subject-matter expert. Editorial policy
Sources & references
Exam facts on this page (fees, format, dates, passing scores) are checked against these official sources; the date is our last check. Editorial policy
- utrmga.org — Test delivery, eligibility, fees, exam format, passing score, registration, retake fee, retake policy, time limit · verified Oct 2026