← All 306A Flashcard Decks

Fixture Installation Flashcards

6 cards from real 306A practice questions. Tap to flip, then mark Knew It or Still Learning — missed cards come back until you master them.

Read the first 6 Fixture Installation flashcards as text
  1. What is the minimum size of a trap required for a residential bathtub?

    Answer: 1½ inch

    A residential bathtub requires a minimum 1½-inch trap to handle the drainage flow rate from the bathtub without causing excessive backup or slow drainage.

  2. When installing a bidet, what backflow prevention device is required?

    Answer: A vacuum breaker on the hot and cold supplies

    A vacuum breaker is required on the bidet's hot and cold water supplies because the spray nozzle can be submerged below the flood level rim, creating a potential cross-connection with the potable water supply.

  3. What is the purpose of an 'overflow' on a lavatory basin?

    Answer: To prevent the basin from overflowing if the drain is closed and the faucet is left running

    The overflow opening near the top of the lavatory basin allows water to drain into the waste pipe if the basin is plugged and the faucet is left running, preventing water from spilling onto the floor.

  4. What is the correct sequence for roughing in a shower installation?

    Answer: Install the framing, set the drain to the correct height, install the valve body at the correct depth, and connect supply and drainage

    The correct sequence is: frame the shower stall, set the drain at the correct height relative to the finished floor, install the valve body at the correct depth behind the finished wall surface, and connect all supply and drainage piping.

  5. What type of trap is required under a kitchen sink with a food waste disposer?

    Answer: P-trap connected to a properly vented drain

    A P-trap connected to a properly vented drain is required under a kitchen sink with a food waste disposer. The disposer does not replace the need for a trap and vent to prevent sewer gas entry.

  6. When installing an accessible (barrier-free) water closet, what is the required seat height?

    Answer: 430 mm to 480 mm (17 to 19 inches)

    Accessible water closets must have a seat height of 430 to 480 mm (17 to 19 inches) to facilitate easier transfer from a wheelchair and provide a more comfortable height for people with mobility limitations.