← All 313A Flashcard Decks

Electrical Controls & Wiring Flashcards

6 cards from real 313A practice questions. Tap to flip, then mark Knew It or Still Learning — missed cards come back until you master them.

Read the first 6 Electrical Controls & Wiring flashcards as text
  1. What is the purpose of a defrost timer in a refrigeration system?

    Answer: To initiate defrost cycles at preset time intervals and terminate them after a set duration or when a termination thermostat trips

    A defrost timer initiates defrost at programmed intervals (e.g., every 6 or 8 hours) and terminates the defrost cycle when a time limit or defrost termination thermostat setpoint is reached, then returns the system to normal cooling.

  2. What does a dual-pressure control combine into a single device?

    Answer: A high-pressure cutout and a low-pressure cutout in one housing, with separate adjustable setpoints for each

    A dual-pressure control combines a high-pressure safety cutout and a low-pressure cutout (or low-pressure pump-down control) in one device, allowing both functions with a single installation.

  3. In an HVAC electrical schematic, what does a normally open (NO) contact symbol indicate?

    Answer: A contact that is open (non-conducting) in its de-energized (resting) state and closes when the associated coil or mechanism is actuated

    A normally open contact is open (circuit broken) when the relay or switch is in its rest state, and closes (conducts) when the coil is energized or the switch is actuated, completing the circuit.

  4. What is the function of a motor start capacitor in a single-phase PSC or CSIR compressor?

    Answer: To provide a phase-shifted current to the start winding to create a rotating magnetic field and initiate motor rotation

    A start capacitor shifts the phase of the current in the start winding relative to the run winding, creating a rotating magnetic field that produces starting torque; it is switched out of the circuit once the motor reaches operating speed.

  5. What does megohm testing (megging) a compressor motor winding indicate?

    Answer: The insulation resistance of the motor windings to ground, indicating whether insulation breakdown or moisture contamination has occurred

    A megohmmeter applies a high DC voltage (typically 500 V) to the motor winding and measures the resistance to ground; low megohm readings indicate degraded insulation, moisture ingress, or early winding failure.

  6. What is the purpose of a time-delay relay (anti-short-cycle timer) in a compressor control circuit?

    Answer: To prevent the compressor from restarting immediately after shutdown, allowing pressures to equalize and protecting the motor from high-torque restarts

    An anti-short-cycle timer prevents the compressor from restarting for a preset period (typically 3–5 minutes) after shutdown, allowing system pressures to equalize and protecting the motor from the strain of starting against high differential pressure.

How this page was made: written with AI tools and published by Nathan Beja, founder of Practice Test Geeks, who is responsible for its content. Exam facts are checked against the official sources listed below. Not reviewed by a subject-matter expert. Editorial policy

Sources & references

Exam facts on this page (fees, format, dates, passing scores) are checked against these official sources; the date is our last check. Editorial policy

  1. skilledtradesontario.ca — Score validity, eligibility, retake policy, renewal, fees, test delivery, passing score, score release, time limit · verified Oct 2026
  2. red-seal.ca — Exam format · verified Oct 2026