ARRT Radiography Certification Examination — Questions and Answers
Question 1: Which patient condition requires the greatest caution and individualized risk-benefit assessment before administering iodinated IV contrast?
- Chronic kidney disease with eGFR 20 mL/min/1.73m² (Correct answer)
- History of previous mild urticaria from shellfish
- Mild controlled asthma
- Seasonal allergic rhinitis
Correct answer: Chronic kidney disease with eGFR 20 mL/min/1.73m²
An eGFR of 20 mL/min/1.73m² represents severe chronic kidney disease, placing the patient at significant risk for contrast-induced acute kidney injury and requiring careful risk-benefit evaluation.
Question 2: Which of the following drug delivery systems falls under the definition of "parenteral"?
- oral
- sublingual
- mucosal
- other, except alimentary (Correct answer)
Correct answer: other, except alimentary
Parenteral drug administration refers to routes that bypass the gastrointestinal (alimentary) tract. This includes various methods such as injections (intravenous, intramuscular, subcutaneous), as well as other non-oral routes like topical, transdermal, or inhaled. Therefore, 'other, except alimentary' accurately encompasses the diverse drug delivery systems defined as parenteral.
Question 3: What is the correct SID (source-to-image distance) for routine chest radiography?
- 72 inches (180 cm) (Correct answer)
- 56 inches (140 cm)
- 48 inches (120 cm)
- 40 inches (100 cm)
Correct answer: 72 inches (180 cm)
A 72-inch (180 cm) SID is standard for chest radiography to minimize cardiac magnification and improve image sharpness.
Question 4: During a quality control assessment, kVp accuracy is typically evaluated using a:
- Densitometer
- Penetrometer
- Digital kVp meter (non-invasive kVp meter) (Correct answer)
- Sensitometer
Correct answer: Digital kVp meter (non-invasive kVp meter)
Non-invasive digital kVp meters measure the actual peak kilovoltage output of the x-ray unit and are used to verify kVp accuracy during quality control.
Question 5: Which radiographic positioning term describes the patient lying face down?
- Trendelenburg
- Lateral decubitus
- Prone (Correct answer)
- Supine
Correct answer: Prone
Prone describes the patient positioned face down on the table, opposite to the supine (face up) position.
Question 6: Which artifact in CT appears as alternating bright and dark bands radiating from high-density structures and is caused by insufficient sampling?
- Partial volume artifact
- Streak artifact (Correct answer)
- Beam hardening artifact
- Ring artifact
Correct answer: Streak artifact
Streak artifacts appear as bright and dark bands radiating from high-density objects (e.g., metal implants, dense bone) and result from insufficient projection data or beam hardening at those locations.
Question 7: Which QC test is performed to evaluate the accuracy of the radiographic timer?
- Step wedge test
- Sensitometry
- Spinning top test (Correct answer)
- Half-value layer measurement
Correct answer: Spinning top test
The spinning top test evaluates timer accuracy in single-phase or three-phase generators by counting the number of dots or arc produced during a timed exposure. Digital systems require a synchronous spinning top or electronic timer test.
Question 8: Window width (WW) and window level (WL) in CT imaging refer to:
- The slice thickness and reconstruction interval
- The matrix size and pixel size of the image
- The range and center of HU values displayed as the visible gray scale (Correct answer)
- The tube voltage and tube current used for the scan
Correct answer: The range and center of HU values displayed as the visible gray scale
Window width sets the range of Hounsfield units mapped to the visible gray scale; window level sets the center HU of that range — together they optimize tissue contrast display.
Question 9: A pediatric patient is brought in for a femur X-ray. Multiple healed fractures in various stages of healing are noted on the image. The radiographer should:
- Inform the radiologist of the findings immediately (Correct answer)
- Discharge the patient and family
- Repeat the images for better quality
- Proceed with the exam and say nothing
Correct answer: Inform the radiologist of the findings immediately
Multiple fractures in various stages of healing in a pediatric patient are a classic radiographic sign of non-accidental trauma (child abuse). The radiographer has an ethical and legal duty to report this finding immediately to the radiologist and follow institutional protocol.
Question 10: The PA chest radiograph is preferred over the AP projection primarily because it:
- Improves lung field visualization
- Reduces patient dose significantly
- Decreases magnification of the heart (Correct answer)
- Eliminates scatter radiation
Correct answer: Decreases magnification of the heart
With the patient facing the detector (PA), the heart is closer to the image receptor, reducing its geometric magnification.
Question 11: The modulation transfer function (MTF) in digital radiography is a measure of:
- Signal-to-noise ratio
- Detector quantum efficiency
- Spatial resolution — how faithfully the system reproduces fine detail (Correct answer)
- Dynamic range of the detector
Correct answer: Spatial resolution — how faithfully the system reproduces fine detail
MTF quantifies the system's ability to reproduce spatial detail. An MTF of 1.0 means perfect reproduction; values below 1.0 indicate blurring. MTF decreases at higher spatial frequencies (finer detail), and is plotted as a curve to characterize detector resolution performance.
Question 12: Which test evaluates the reproducibility of x-ray output from an x-ray generator?
- Beam quality (HVL) test
- Focal spot resolution test
- Exposure reproducibility test (Correct answer)
- Grid alignment test
Correct answer: Exposure reproducibility test
The exposure reproducibility test measures the variation in radiation output across multiple identical exposures, verifying that the generator produces consistent output.
Question 13: The image matrix size in digital radiography refers to:
- The physical size of the detector panel
- The spatial frequency at which the image is acquired
- The number of pixels arranged in rows and columns that make up the digital image (Correct answer)
- The number of gray levels in the image
Correct answer: The number of pixels arranged in rows and columns that make up the digital image
The image matrix defines how many pixels are arranged in rows × columns to form the digital image — a larger matrix (more pixels) means higher spatial resolution.
Question 14: Primary radiation barriers must attenuate the useful beam to what level?
- The primary barrier must reduce transmission to 5 mSv/week
- The primary barrier must reduce transmission to 10 mSv/week
- The primary barrier must reduce transmission to 0.1 mSv/week
- The primary barrier must reduce transmission to 1 mSv/week (Correct answer)
Correct answer: The primary barrier must reduce transmission to 1 mSv/week
Primary barriers are designed to reduce the transmitted primary beam to an acceptable level, typically 1 mSv (0.1 rem) per week for controlled areas.
Question 15: Which protective measure is most effective in reducing patient dose during pediatric radiography?
- Using a higher kVp and lower mAs
- Tight collimation to the area of clinical interest (Correct answer)
- Increasing the SID to 72 inches for all exams
- Using the fastest film-screen combination available
Correct answer: Tight collimation to the area of clinical interest
Tight collimation limits the x-ray beam to only the area of interest, directly reducing the volume of tissue irradiated and thus the patient dose.
Question 16: Which principle of radiation protection is described as keeping radiation exposure As Low As Reasonably Achievable?
- ALARA (Correct answer)
- MPD
- HVL
- NCRP
Correct answer: ALARA
ALARA stands for As Low As Reasonably Achievable and is the foundational principle guiding all radiation protection practices.
Question 17: How should an Radiography Exam professional present complex information to non-experts?
- Use full technical terminology
- Skip complex topics entirely
- Provide written reports only
- Translate into accessible language, use visuals, and check for understanding (Correct answer)
Correct answer: Translate into accessible language, use visuals, and check for understanding
This is fundamental to Radiography Exam practice. Translate into accessible language, use visuals, and check for understanding represents the professional standard for communication in the Radiography Exam certification framework.
Question 18: Which type of artifact in CR imaging appears as a faint previous image superimposed on the current image?
- Quantum noise artifact
- Aliasing artifact
- Grid cutoff artifact
- Ghost artifact (residual image artifact) (Correct answer)
Correct answer: Ghost artifact (residual image artifact)
Ghost artifacts occur in CR when the PSP plate was not completely erased after the previous exposure — residual electrons release during the next scan, creating a faint superimposed image from the previous study.
Question 19: The major role of x-ray beam filtration is to:
- reduce operator dose.
- reduce scattered radiation.
- reduce patient skin dose. (Correct answer)
- reduce image noise.
Correct answer: reduce patient skin dose.
The primary role of x-ray beam filtration is to remove low-energy, long-wavelength photons from the beam. These 'soft' x-rays would otherwise be absorbed by the patient's skin without contributing to image formation. By removing them, filtration significantly reduces the patient's skin dose while maintaining diagnostic image quality.
Question 20: How do Radiography Exam professionals ensure compliance in daily practice?
- By hiring a compliance officer
- By integrating compliance requirements into standard operating procedures and regular audits (Correct answer)
- Compliance is checked only annually
- By memorizing all regulations
Correct answer: By integrating compliance requirements into standard operating procedures and regular audits
This is fundamental to Radiography Exam practice. By integrating compliance requirements into standard operating procedures and regular audits represents the professional standard for regulatory in the Radiography Exam certification framework.
Question 21: In computed radiography, what material is used in the imaging plate to store the latent image?
- Silver halide crystals
- Cesium iodide
- Amorphous selenium
- Photostimulable phosphor (PSP) (Correct answer)
Correct answer: Photostimulable phosphor (PSP)
CR imaging plates use photostimulable phosphor (typically europium-doped barium fluorohalide) to trap energy from x-rays as a latent image.
Question 22: In digital radiography, what QC test is performed to detect dead pixels or detector non-uniformity?
- Line pair resolution test
- Flat-field uniformity test (Correct answer)
- MTF measurement
- Laser alignment test
Correct answer: Flat-field uniformity test
The flat-field uniformity test exposes the digital detector to a uniform radiation field and analyzes the resulting image for non-uniformity, dead pixels, or detector artifacts that could mimic pathology.
Question 23: Which artifact appears as a regular, wavy interference pattern when a stationary grid is used with an oscillating digital detector?
- Lag artifact
- Moiré pattern (Correct answer)
- Ghosting artifact
- Zebra artifact
Correct answer: Moiré pattern
The moiré pattern is an interference artifact caused by the interaction of the grid frequency with the sampling frequency of the digital detector.
Question 24: What is the recommended practice for wearing a radiation monitoring badge during fluoroscopy when wearing a lead apron?
- Wear two badges: one outside at collar, one under apron at waist (Correct answer)
- Wear one badge at collar level outside the apron
- Wear the badge under the apron at waist level
- Wear the badge on the wrist closest to the beam
Correct answer: Wear two badges: one outside at collar, one under apron at waist
During fluoroscopy, two badges are recommended: one at collar level outside the apron and one under the apron at waist level to accurately estimate effective dose.
Question 25: Which action best demonstrates a radiographer's commitment to professional development?
- Reading new equipment manuals once and filing them away
- Relying exclusively on on-the-job training
- Maintaining ARRT registration and completing required continuing education credits (Correct answer)
- Attending conferences only when required by the employer
Correct answer: Maintaining ARRT registration and completing required continuing education credits
Maintaining ARRT registration and fulfilling continuing education (CE) requirements demonstrates ongoing professional development and ensures competency with evolving technology and practice standards.
Question 26: How do continuing education requirements benefit Radiography Exam certified professionals?
- They reduce practical skills
- They only benefit training providers
- They are unnecessary formalities
- They ensure professionals stay current with evolving industry practices and knowledge (Correct answer)
Correct answer: They ensure professionals stay current with evolving industry practices and knowledge
This is fundamental to Radiography Exam practice. They ensure professionals stay current with evolving industry practices and knowledge represents the professional standard for professional standards in the Radiography Exam certification framework.
Question 27: The term 'contrast extravasation' refers to:
- Leakage of IV contrast from the vein into surrounding soft tissue (Correct answer)
- Allergic reaction to contrast media
- Contrast entering the urinary collecting system
- Contrast passing through the blood-brain barrier
Correct answer: Leakage of IV contrast from the vein into surrounding soft tissue
Contrast extravasation occurs when the IV needle or catheter is not properly positioned, allowing contrast to leak into the perivascular soft tissues rather than flowing into the vein.
Question 28: REM is a unit used to measure radiation. REM stands for what?
- Radiation Equivalent Man (Correct answer)
- Radioactive Early Management
- Radiation Evolved Management
- Roentgen Early Man
Correct answer: Radiation Equivalent Man
REM stands for 'Radiation Equivalent Man' (or Roentgen Equivalent Man). It is an older unit of equivalent dose, used to quantify the biological effect of radiation on human tissue. The REM accounts for the different biological effectiveness of various types of radiation, providing a measure of the potential harm to humans, with the SI unit equivalent being the Sievert (Sv).
Question 29: Which type of radiation interaction is primarily responsible for occupational radiation exposure during diagnostic radiography?
- Coherent scattering
- Photoelectric effect
- Pair production
- Compton scattering (Correct answer)
Correct answer: Compton scattering
Compton scattering is the primary source of scatter radiation that creates occupational exposure in diagnostic radiography, as it produces scattered photons that travel in all directions.
Question 30: Under 21 CFR 1020.31, the minimum source-to-skin distance (SSD) for a stationary fluoroscope is:
- 20 cm (8 inches)
- 30 cm (12 inches)
- 38 cm (15 inches) (Correct answer)
- 15 cm (6 inches)
Correct answer: 38 cm (15 inches)
21 CFR 1020.31 requires a minimum SSD of 38 cm (15 inches) for stationary fluoroscopes and 30 cm (12 inches) for mobile units. This minimum distance protects the patient's skin from high skin entrance doses.
Question 31: A patient receiving iodinated IV contrast suddenly develops generalized urticaria, bronchospasm, and hypotension. This reaction is classified as:
- Vasovagal reaction
- Anaphylactoid (anaphylaxis-like) reaction (Correct answer)
- Chemotoxic reaction
- Contrast-induced nephropathy
Correct answer: Anaphylactoid (anaphylaxis-like) reaction
Generalized urticaria combined with bronchospasm and hypotension constitutes a severe anaphylactoid reaction, which requires immediate emergency treatment with epinephrine.
ARRT Radiography Certification Examination
The ARRT Radiography Examination assesses the knowledge and cognitive skills of radiographers across patient care, radiation safety, image production, and imaging procedures. It is administered by the American Registry of Radiologic Technologists (ARRT) and is required for radiography certification.
Exam Rules
- You can skip questions and return to them later
- Flag questions for review before submitting
- No feedback shown until you submit the entire exam
- Unanswered questions count as wrong — answer everything
- 10 pretest questions are mixed in and don't affect your score
- Timer auto-submits when time runs out
- Your progress is auto-saved every 30 seconds
These practice questions were written with AI tools. They are not real exam questions. Exam facts are checked against the official sources listed below. Not reviewed by a subject-matter expert. Editorial policy
Sources & references
Exam facts on this page (fees, format, dates, passing scores) are checked against these official sources; the date is our last check. Editorial policy
- arrt.org — Score validity, retake policy, test delivery, eligibility, passing score, score release, fees, exam information · verified Oct 2026
- home.pearsonvue.com — Registration deadline · verified Oct 2026
- assets-us-01.kc-usercontent.com — Exam format, registration, time limit · verified Oct 2026