QEI Qualified Elevator Inspector Practice Test PDF 2026
QEI exam: 8 hours (plus one scheduled 30-minute break). Prepare for the QEI Qualified Elevator Inspector certification.
QEI Qualified Elevator Inspector Practice Test PDF 2026
Preparing for the NAESA QEI exam? A printable QEI practice test PDF puts the core inspection knowledge you need in a portable, distraction-free format. The Qualified Elevator Inspector certification tests a broad range of technical domains — elevator types, ASME safety codes, inspection procedures, safety device operation, and maintenance requirements. This guide covers all the major QEI exam content areas so you can study with confidence. Practice with the free QEI - Qualified Elevator Inspector practice test on PracticeTestGeeks (11 questions with answer explanations).
NAESA QEI Certification Overview
The Qualified Elevator Inspector (QEI) certification is administered by the National Association of Elevator Safety Authorities International (NAESA International). It is the primary professional credential for elevator inspectors in North America and is recognized or required in numerous state and local jurisdictions as evidence of inspector competency.
The QEI exam tests knowledge of elevator, escalator, moving walk, and related equipment inspection as defined in the ASME A17.1/CSA B44 Safety Code for Elevators and Escalators. Candidates must demonstrate understanding of equipment types, code requirements, inspection procedures, safety device function, and the documentation requirements for elevator inspections.
Eligibility typically requires a combination of industry experience (direct hands-on work with elevator equipment) and/or formal education in elevator mechanics or inspection. NAESA publishes specific experience requirements on their website, and these change with each exam cycle.
- The NAESA QEI certification exam is an online, open-book exam with 160 multiple-choice code questions, plus 6 demographic questions used only for statistics. (dropbox.com)
- Candidates get 8 hours of testing time for the NAESA QEI exam, with one required 30-minute break, and should expect to be at the test site for about 9 hours. (dropbox.com)
- To pass the NAESA QEI exam you need a score of 555 or higher, and candidates are told only whether they passed or failed, not their numerical score. (dropbox.com)
- The NAESA International QEI certification exam costs $500 on its own, and NAESA membership is included if you pass. (NAESA International (National Association of Elevator Safety Authorities), a certifying organization accredited to ASME)
- The NAESA International QEI Training Course and Certification Exam package costs $1,295, and NAESA membership is included if you pass. (NAESA International (National Association of Elevator Safety Authorities), a certifying organization accredited to ASME)
- Retaking the NAESA QEI exam (exam only) costs $400, and the retake fee does not include NAESA membership. (NAESA International (National Association of Elevator Safety Authorities), a certifying organization accredited to ASME)
- After failing the NAESA QEI exam, a candidate must wait at least two months before retesting, and before a third or later attempt must also wait for the next edition of the exam. (dropbox.com)
- To renew NAESA QEI certification each year, inspectors complete 1.0 CEU (10 hours) of approved continuing education and the online Maintenance of Qualifications survey, and pay $200 (members) or $250 (non-members). (NAESA International (National Association of Elevator Safety Authorities), a certifying organization accredited to ASME)
- The NAESA QEI exam is taken online under supervision, either at a session NAESA schedules or at an approved location the candidate chooses (such as their office, a library or a testing center) with two approved proctors. (NAESA International (National Association of Elevator Safety Authorities), a certifying organization accredited to ASME)
Facts verified Oct 21, 2026 against NAESA International (National Association of Elevator Safety Authorities), a certifying organization accredited to ASME. Dates that have passed are removed automatically.
QEI Exam at a Glance
| Item | Detail | Official source |
|---|---|---|
| Number of questions | 160 multiple-choice questions (open book, plus 6 demographic questions) | dropbox.com |
| Time limit | 8 hours (plus one 30-minute break) | dropbox.com |
| Passing score | Scaled score of 555 or above (pass/fail only) | dropbox.com |
| Exam fee (Exam Only) | $500 (exam only, includes membership with a passing grade) | NAESA International (National Association of Elevator Safety Authorities), a certifying organization accredited to ASME |
| Exam fee (Training Course + Exam) | $1,295 (training course + exam, includes membership with a passing grade) | NAESA International (National Association of Elevator Safety Authorities), a certifying organization accredited to ASME |
| Retake fee | $400 per retake (no membership included) | NAESA International (National Association of Elevator Safety Authorities), a certifying organization accredited to ASME |
| Retake policy | Wait at least 2 months after a failed attempt; from the 3rd attempt on, wait for the next exam edition | dropbox.com |
| Renewal | Annual: 1.0 CEU (10 hours) + MOQ survey + $200 (members) / $250 (non-members) | NAESA International (National Association of Elevator Safety Authorities), a certifying organization accredited to ASME |
| Delivery | Online, proctored: at a NAESA-scheduled session or at an approved location you choose with 2 proctors | NAESA International (National Association of Elevator Safety Authorities), a certifying organization accredited to ASME |
| Eligibility | Meet the ASME QEI-1 experience requirements (at least 1 year of supervised inspection experience) and get the application approved | NAESA International (National Association of Elevator Safety Authorities), a certifying organization accredited to ASME |
| Score release | By email within 5 business days | dropbox.com |
Facts verified Oct 21, 2026 against NAESA International (National Association of Elevator Safety Authorities), a certifying organization accredited to ASME. Dates that have passed are removed automatically.
Free QEI - Qualified Elevator Inspector Study Tools
Interactive QEI - Qualified Elevator Inspector resources on PracticeTestGeeks, free to start:
- Free QEI Elevator Safety Regulations Question and Answers — 11 questions with instant scoring and answer explanations
- QEI - Qualified Elevator Inspector flashcards — review key terms and concepts card by card
- QEI - Qualified Elevator Inspector study guide — topic-by-topic overview of what the exam covers
- QEI - Qualified Elevator Inspector cheat sheet — one-page printable summary for last-minute review
Did You Know? Passing the QEI exam on your first attempt saves both time and money. Start with diagnostic practice tests to identify your weak areas.
- ✓Confirm your exam appointment and location
- ✓Bring required identification documents
- ✓Arrive 30 minutes early to check in
- ✓Read each question carefully before answering
- ✓Flag difficult questions and return to them later
- ✓Manage your time — don't spend too long on one question
- ✓Review flagged questions before submitting
- ✓Elevator Types — electric traction, hydraulic, limited use/limited application, inclined, special
- ✓Escalators and Moving Walks — step/pallet systems, handrail systems, safety devices
- ✓ASME A17.1/CSA B44 Safety Code — code structure, requirements by equipment type, violations
- ✓Inspection Procedures — periodic and acceptance inspection procedures, documentation
- ✓Safety Devices — safeties, buffers, interlocks, governors, overspeed protections
- ✓Maintenance and Testing — firefighters' service, emergency operations, annual tests
- ✓Accident Investigation — post-incident inspection requirements, documentation, reporting
Elevator Types and Systems
The QEI exam requires detailed knowledge of different elevator types, their drive systems, and the code requirements specific to each. The major categories:
Electric Traction Elevators — The most common type in commercial and high-rise buildings. A traction elevator uses a motor-driven sheave (wheel) over which ropes (or flat belts in newer MRL installations) are draped, with the car on one side and counterweight on the other. Subtypes include:
- Geared traction: Motor drives a worm gear reduction unit connected to the sheave. Common in mid-rise buildings (6–12 floors). Speed typically 100–450 FPM.
- Gearless traction: Motor drives the sheave directly. Used in high-rise buildings. Speed can exceed 1,000 FPM. Requires less maintenance due to fewer mechanical components.
- Machine Room-Less (MRL): Drive machine is located in the hoistway or overhead (no separate machine room required). Uses permanent magnet synchronous motor (PMSM) technology. Code requirements for MRL differ from traditional traction in accessibility, maintenance space, and emergency recall procedures.
Hydraulic Elevators — Use a hydraulic piston driven by a pump unit to raise and lower the car. Subtypes:
- Holeless hydraulic: Telescoping or side-mounted cylinder that does not extend into the ground. Required when underground boring is impractical.
- In-ground (holed) hydraulic: Traditional type with a single or telescoping cylinder extending below the pit floor into the ground. Requires environmental containment due to fluid spill risk.
- Roped hydraulic: Uses ropes and a short cylinder with mechanical advantage to reduce the cylinder length needed. Often used when a full-length cylinder is impractical.
Key code requirements for hydraulic elevators that appear on QEI exams: pressure relief valve settings, rupture valve (underslung piping), lowering valve and manual lowering capability, power unit location, fluid containment requirements.
Limited Use/Limited Application (LU/LA) Elevators — Smaller elevators with reduced travel and capacity used primarily for ADA accessibility in low-rise buildings where a standard elevator is not justified. LU/LA elevators have separate ASME A17.1 code requirements (Rule 5.3) with specific cab size, travel, speed, and safety device requirements that differ from standard electric traction.
Inclined Elevators and Stairway Chairlifts — Travel on an inclined path. Chairlifts, stair lifts, and inclined platform lifts are covered under ASME A18.1 (Platform Lifts and Stairway Chairlifts), not A17.1. QEI candidates must know which code applies to which equipment type.
ASME A17.1/CSA B44 Safety Code
The ASME A17.1/CSA B44 is the primary reference for QEI exam content. Understanding its structure is as important as knowing individual requirements.
The code is organized into major parts (Sections 1 through 9 for the core code, with appendices). The section structure the QEI exam draws from most heavily:
- Section 1: Electric Elevators — hoistway, machine room, car, landing, safety devices, operating equipment
- Section 2: Hydraulic Elevators — hydraulic system requirements, pressure components, pit requirements
- Section 3: Escalators and Moving Walks
- Section 5: Special application elevators (LU/LA, residential, inclined)
- Section 8: Inspection and testing — acceptance and periodic inspection requirements
- Section 9: Alterations — when alterations require full compliance with current code vs. compliance with the edition in force at installation
Section 8 is among the most tested sections because it directly defines the inspector's job. Key concepts: the distinction between periodic inspection (routine inspections of in-service equipment) and acceptance inspection (inspection of new or altered installations before being placed in service), the frequency requirements for periodic inspections, and the documentation requirements for both.
Elevator Safety Devices
Safety devices are heavily tested on the QEI exam. Each device has a specific function, operating condition, and code requirement that inspectors must know in detail.
Governor and Safety (Car Safety) — The governor is a centrifugal speed-sensing device located in the machine room (or hoistway for some MRL designs). When the car descends at overspeed, the governor trips and sets the car safety by applying the safety jaws to the guide rails. The car safety is the last line of defense against uncontrolled descent.
Types of car safeties:
- Instantaneous safety: Applies abruptly. Limited to low-speed applications (under 150 FPM). Produces higher stopping deceleration.
- Progressive/gradual safety: Applies progressively, producing lower deceleration forces. Required for higher-speed elevators. Uses springs or rollers to control application rate.
Buffers — Located in the pit below the car and counterweight to absorb kinetic energy in the event of over-travel to the bottom terminal. Types:
- Spring buffers: Permitted for elevator speeds of 200 FPM or less. Energy storage type.
- Oil (hydraulic) buffers: Required for elevators operating above 200 FPM. Energy dissipation type. Must be fully extended before the car is put back in service after engagement.
Hoistway Door Interlocks — Prevent hoistway doors from being opened from the landing side unless the car is in the landing zone AND the car is stopped or nearly stopped. The interlock also prevents the car from moving unless all hoistway doors are locked. Door interlocks are among the most safety-critical components on an elevator — their failure has caused the majority of fatal elevator entrapment incidents.
Key interlock code requirements: each hoistway door must have an interlock; the interlock must prevent door opening unless the car is within the landing zone (typically within 18 inches); the interlock must lock the door closed and prove locking before car movement; testing must verify the lock strength meets code requirements.
Electrical Safety Devices — The safety circuit (safety chain) is a series circuit of all safety switches. Any open switch de-energizes the elevator control circuit and stops the car. Components in the safety circuit include: governor switch, pit stop switch, car safety switch, buffer switches, door interlocks, terminal stopping devices, slack rope/chain switches, and others. The QEI inspector must verify that each safety device in the circuit is functional and that the circuit cannot be bypassed.
Counterweight Safeties — Required when the hoistway extends below the pit floor or when clearances below the counterweight are insufficient for personnel safety. Counterweight safeties function similarly to car safeties but protect against counterweight overspeed in the upward direction.
Escalators and Moving Walks
Escalators and moving walks are covered under ASME A17.1 Section 6 (escalators) and Section 7 (moving walks), and QEI candidates are tested on their unique inspection requirements.
Escalator Safety Devices:
- Step/skirt deflectors: Minimize the gap between the step tread and skirt panel. Prevent entrapment of soft materials (shoelaces, clothing).
- Handrail speed monitoring: Detects when the handrail speed deviates from step speed by more than a defined percentage. Stops the escalator if the handrail is significantly slower or faster than the steps.
- Combplate impact switches: Stop the escalator if an object lodges between the steps and the combplate at the landing. Located at both the upper and lower landing.
- Stop buttons: Required at each landing and accessible to the public. QEI inspectors verify stop buttons halt the escalator within required stopping distance.
- Skirt obstruction device: Stops the escalator if the gap between the skirt and step exceeds the maximum allowed clearance.
Escalator Inspection Key Points: Tread depth, riser height, and tread edge markings must meet code. Step level device confirms all steps are level in the passenger area. Escalator braking distance (stopping distance under overspeed or reversal) must be within code limits. Handrail entry guards prevent hands/objects from being drawn into the handrail newel.
Inspection Procedures and Documentation
Section 8 of ASME A17.1 defines inspection procedures in detail. QEI exam questions focus on what inspectors must check, how, and the documentation requirements.
Acceptance Inspection — Conducted before new or altered equipment is placed in service. The inspector verifies that all equipment meets the applicable code edition. A certificate of compliance is issued if the inspection passes. For new installations, the acceptance inspection includes witnessing full-load tests, safety device tests, and firefighters' service tests.
Periodic Inspection — Conducted at intervals defined by code or local jurisdiction (typically annually, though some jurisdictions require more frequent inspection for high-use equipment). The periodic inspection includes a visual inspection of all accessible components plus operational tests of safety-critical functions.
Required Tests — The QEI exam tests knowledge of specific test procedures and acceptance criteria:
- Firefighters' emergency operation Phase I and Phase II: Phase I (lobby recall) — all cars return to main floor when fire alarm activates or Phase I switch at lobby is turned to recall position. Phase II (in-car operation) — firefighter uses in-car switch to operate elevator manually. QEI inspects switch function, door hold-open operation, and car leveling in Phase II mode.
- Governor tripping speed test: Governor must trip within the specified RPM range. Verified during governor test.
- Safety test: Car safety must stop the car within required deceleration limits when governor trips. Performed with the car at rated load (or as specified).
- Buffer test: Oil buffers must be fully returned to extended position before car returns to service. Spring buffer tests verify oil level and stroke.
- Brake test: Brake must hold the car and rated load on stopping and prevent movement under overspeed conditions.
Accident Investigation
When an elevator accident or near-miss occurs, the inspector has specific obligations under ASME A17.1 and most state/local elevator codes. QEI exam questions address the inspector's role in post-accident procedures.
Key accident investigation principles:
- The elevator must be taken out of service immediately after a serious accident and not returned to service until an inspection is completed and any deficiencies corrected.
- The scene must be preserved to the extent possible — evidence (cable, components, door interlocks) must not be removed or altered until the inspection is complete.
- Documentation must include: date, time, location, description of incident, condition of equipment, names of witnesses, description of all deficiencies found.
- Reports must be filed with the authority having jurisdiction (AHJ) within required timeframes. Most jurisdictions require notification within 24 hours for accidents with serious injury.
- Photographs and measurements are essential — inspectors document the physical state of every safety device and operating condition relevant to the incident.
Sample QEI - Qualified Elevator Inspector Practice Questions
Try these questions from our free QEI - Qualified Elevator Inspector practice tests. The correct answer and an explanation follow each question.
During a Category 3 periodic test on a direct-acting hydraulic elevator, a pressure test is performed on the cylinder. What is the primary hazard this test is designed to detect?
- A. Improper setting of the system relief valve.
- B. A gradual drop in the car's position over time (drift).
- C. A leak in the underground cylinder or piping.
- D. Failure of the plunger gripper device to engage.
Answer: C. A leak in the underground cylinder or piping.
The Category 3 pressure test (performed every 3 years) is specifically designed to detect leaks in the cylinder and any associated buried piping. This is a critical safety and environmental test, as an undetected leak could lead to a catastrophic failure or ground contamination.
A QEI inspects a traction elevator machine room where sprinklers are installed. The inspector notes that the means to disconnect the main line power to the elevator (shunt trip) is activated by a smoke detector located at the top of the hoistway. Why is this a code violation?
- A. The disconnect should only be activated by the building's main fire alarm panel.
- B. Smoke detectors are not permitted to activate the shunt trip device.
- C. The disconnect must be activated by a manual switch in the fire command center.
- D. The smoke detector must be located in the machine room, not the hoistway.
Answer: B. Smoke detectors are not permitted to activate the shunt trip device.
ASME A17.1, Rule 2.8.3.3.2, and NFPA 72 require that the activation of the shunt trip device be initiated by a heat detector, not a smoke detector. This is to ensure power is cut immediately *before* the application of water from the sprinkler, which is predicted by high heat. A smoke detector could shut down the elevator prematurely, potentially trapping passengers before a fire has grown to the point of sprinkler activation.
An inspector notes that the main power disconnect for a traction elevator is located in an electrical closet adjacent to the machine room. The disconnect is not visible from the location of the elevator controller. According to NEC 620.51, why is this a violation?
- A. The disconnect is not rated for the motor horsepower.
- B. The disconnect must be located within sight of the motor controller.
- C. The disconnect must be located inside the machine room, within 24 inches of the door.
- D. The disconnect cannot be in a room with other electrical panels.
Answer: B. The disconnect must be located within sight of the motor controller.
NEC 620.51(C) requires the disconnecting means to be located within sight of the motor controller. This is a critical safety requirement to ensure that a technician working on the controller can visually confirm that the power source has been de-energized.
An inspector is examining a newly installed hydraulic elevator in a five-story building. The elevator's rated speed is 150 feet per minute (0.76 m/s). Which type of buffer would be required at the bottom of the hoistway?
- A. Spring buffers, because they are cost-effective.
- B. Solid rubber bumpers, as they require no maintenance.
- C. Oil buffers, because the speed is greater than 1.0 m/s.
- D. No buffers are required if the elevator has a plunger gripper.
Answer: C. Oil buffers, because the speed is greater than 1.0 m/s.
ASME A17.1 mandates the use of oil buffers for elevators with a rated speed exceeding 1.0 m/s (approximately 200 ft/min). While spring buffers are suitable for lower-speed elevators, oil buffers are required to safely dissipate the kinetic energy of a car traveling at higher speeds, providing a controlled and gradual stop.
Take the full QEI - Qualified Elevator Inspector practice test
How this page was made: written with AI tools and published by Nathan Beja, founder of Practice Test Geeks, who is responsible for its content. Exam facts are checked against the official sources listed below. Not reviewed by a subject-matter expert. Editorial policy
Sources & references
Exam facts on this page (fees, format, dates, passing scores) are checked against these official sources; the date is our last check. Editorial policy
- naesai.org — Renewal, test delivery, eligibility, fees, retake fee · verified Nov 2026
- dropbox.com — Exam format, passing score, registration deadline, retake policy, score release, time limit · verified Nov 2026