A patient's prescription is -6.50 D sphere. The optical center (OC) is inadvertently placed 4 mm below the pupil center. How much prismatic effect does the patient experience, and in what direction?
-
A
2.6 Prism Diopters Base Up
-
B
2.6 Prism Diopters Base Down
-
C
1.63 Prism Diopters Base In
-
D
1.63 Prism Diopters Base Out