Electrical Safety Standards Flashcards
21 cards from real OSHA practice questions. Tap to flip, then mark Knew It or Still Learning — missed cards come back until you master them.
Read the first 20 Electrical Safety Standards flashcards as text
Under OSHA's lockout/tagout standard (29 CFR 1910.147), who is authorized to remove a lockout device?
Answer: The employee who applied it, or per a documented removal procedure if absent
Only the authorized employee who applied the device removes it, unless a documented procedure allows removal when that employee is unavailable.
What is the primary purpose of grounding electrical equipment?
Answer: To provide a low-resistance path for fault current to safely dissipate
Grounding creates a low-resistance path that safely carries fault current away, reducing shock and fire risk.
A GFCI protects workers primarily by detecting what condition?
Answer: An imbalance between hot and neutral current (ground fault)
A GFCI trips when current leaking to ground creates an imbalance between the hot and neutral conductors.
OSHA requires that flexible cords and cables be protected from which hazard?
Answer: Damage from sharp corners, pinching, or vehicle traffic
Cords must be protected from physical damage such as pinching, sharp edges, and passing traffic.
Which condition allows work on energized parts under OSHA rules?
Answer: When de-energizing introduces greater hazard or is infeasible
Energized work is only permitted when de-energizing increases hazards or is infeasible for the task.
What does the color of an electrical conductor's insulation typically indicate?
Answer: The conductor's function such as hot, neutral, or ground
Insulation color coding identifies conductor function—for example green or bare for ground, white for neutral.
Why must overcurrent protection devices (fuses/breakers) be sized correctly?
Answer: To interrupt current before conductors overheat and cause fire
Properly sized breakers or fuses trip before conductors overheat, preventing fires.
What is the recommended first action if a coworker is in contact with a live electrical source?
Answer: De-energize the source or use a non-conductive object; do not touch them directly
Never touch a victim still in contact with power; shut off the source or separate them with a non-conductive object.
Arc flash hazards are best mitigated by which control?
Answer: De-energizing equipment and wearing rated arc-flash PPE when live work is unavoidable
De-energizing eliminates arc flash risk; when live work is required, arc-rated PPE is essential.
What is the minimum working clearance concern OSHA addresses around electrical panels?
Answer: Adequate space must be kept clear for safe access and operation
OSHA requires sufficient clear working space in front of electrical equipment for safe access.
Double-insulated power tools are marked with which symbol?
Answer: A square within a square
The square-within-a-square symbol indicates a double-insulated tool that does not require a grounding prong.
Before using a portable electric tool, a worker should inspect for what?
Answer: Damaged cords, cracked housings, and missing ground prongs
Pre-use inspection should catch frayed cords, cracked casings, and missing grounding pins.
What hazard results from using an undersized extension cord for a high-load tool?
Answer: Overheating and voltage drop that can cause fire or tool damage
Undersized cords overheat and cause excessive voltage drop, risking fire and equipment damage.
Wet locations increase electrical hazard because water does what?
Answer: Lowers skin resistance and conducts current more easily
Moisture lowers the body's resistance and conducts electricity, greatly increasing shock severity.
The first step in the lockout/tagout procedure is to:
Answer: Notify affected employees and prepare for shutdown
LOTO begins with preparation and notifying affected employees before shutting down the equipment.
After applying locks in LOTO, why must stored energy be released or restrained?
Answer: Because springs, capacitors, or pressure can still cause injury
Residual stored energy in capacitors, springs, or pressure systems must be released to prevent unexpected release.
A tag used alone (without a lock) provides what level of protection?
Answer: A warning only, with no physical restraint
A tag is only a warning device and does not physically prevent equipment from being energized.
How should a worker verify that equipment is truly de-energized before servicing?
Answer: Test with a properly rated voltage tester (verify tester on known live source first)
Verify zero energy using a rated tester, and confirm the tester works on a known live source before and after.
What is a key requirement for extension cords used on construction sites under OSHA?
Answer: They must be three-wire type (grounded) and rated for hard/extra-hard use
Construction extension cords must be grounded three-wire type rated for hard or extra-hard service.
Metal ladders are discouraged near electrical work because they:
Answer: Conduct electricity and increase electrocution risk
Metal ladders conduct electricity, so non-conductive fiberglass ladders are safer near electrical hazards.
How this page was made: written with AI tools and published by Nathan Beja, founder of Practice Test Geeks, who is responsible for its content. Exam facts are checked against the official sources listed below. Not reviewed by a subject-matter expert. Editorial policy