← All OFTEC Flashcard Decks

Oil Pipework and Supply Systems Flashcards

7 cards from real OFTEC practice questions. Tap to flip, then mark Knew It or Still Learning — missed cards come back until you master them.

Read the first 7 Oil Pipework and Supply Systems flashcards as text
  1. What colour is MDPE (medium-density polyethylene) pipe approved for oil supply use in the UK?

    Answer: Black

    Black MDPE pipe is approved for oil supply use in the UK; yellow MDPE is used for gas distribution and blue MDPE is used for potable water supplies.

  2. What is the minimum depth of cover required for buried oil supply pipework under a non-trafficked area such as a garden?

    Answer: 450mm

    Under non-trafficked areas, a minimum cover of 450mm is required for buried oil supply pipework to provide adequate protection from accidental damage.

  3. What minimum depth of cover is required for buried oil supply pipework passing under a driveway or other trafficked area?

    Answer: 600mm

    Buried oil supply pipework under driveways or trafficked areas requires a minimum cover of 600mm to provide protection against damage from vehicle loads.

  4. Which type of joint is NOT suitable for use in buried oil supply pipework?

    Answer: Soldered (capillary) joints on copper tube

    Soldered (capillary) joints are not suitable for buried oil pipework as they can fail under ground movement stresses and are not approved for underground oil service.

  5. When oil supply pipework passes through a wall or floor, what protection must be provided?

    Answer: A sleeve to protect the pipe and allow for thermal movement

    Oil supply pipework must be enclosed in a sleeve when passing through walls or floors to protect it from physical damage and to accommodate thermal expansion and contraction.

  6. What is the maximum recommended length of flexible hose connection between the oil supply pipework and the burner?

    Answer: 500mm

    The maximum recommended length for a flexible connection between the oil supply pipe and the burner is 500mm; longer connections increase the risk of hose failure.

  7. Where should the body of a fire valve be positioned relative to the appliance room?

    Answer: Outside or away from the area where fire could occur, with only the sensing phial inside the room

    The fire valve body must be positioned outside the area where fire could occur, with only the sensing phial inside the room, ensuring the valve itself remains undamaged and able to operate if fire breaks out.

How this page was made: written with AI tools and published by Nathan Beja, founder of Practice Test Geeks, who is responsible for its content. Exam facts are checked against the official sources listed below. Not reviewed by a subject-matter expert. Editorial policy

Sources & references

Exam facts on this page (fees, format, dates, passing scores) are checked against these official sources; the date is our last check. Editorial policy

  1. bpec.org.uk — Retake policy · verified Oct 2026
  2. oftec.org — Fees, renewal, eligibility, exam format, score validity, test delivery · verified Oct 2026