Fireplaces, Chimneys and Solid-Fuel Burning Appliances Flashcards
6 cards from real NHIE practice questions. Tap to flip, then mark Knew It or Still Learning — missed cards come back until you master them.
Read the first 6 Fireplaces, Chimneys and Solid-Fuel Burning Appliances flashcards as text
Under the common 3-2-10 rule, how high must a masonry chimney extend?
Answer: At least 3 feet above the roof penetration and 2 feet higher than any part of the building within 10 feet
The IRC 3-2-10 rule says a chimney must extend at least 3 feet above the point where it passes through the roof. It must also be at least 2 feet higher than any part of the building within 10 feet horizontally. This gives proper draft and keeps sparks away from the roof.
A masonry fireplace has an opening of less than 6 square feet. What is the minimum hearth extension in front of the opening?
Answer: 16 inches
For openings under 6 square feet, the hearth extension must reach at least 16 inches in front of the opening and 8 inches past each side. For openings of 6 square feet or more, it must reach 20 inches in front and 12 inches past each side.
What is the minimum air-space clearance between combustible framing and a masonry chimney located entirely inside the house?
Answer: 2 inches
The IRC requires 2 inches of clearance between combustibles and masonry chimneys located inside the building. Chimneys on the exterior of the building need only 1 inch. Framing that touches the masonry is a fire hazard and should be reported.
When is a cricket (saddle) required on the uphill side of a chimney?
Answer: When the chimney is wider than 30 inches measured perpendicular to the roof slope
The IRC requires a cricket when the chimney is more than 30 inches wide parallel to the ridge, that is, across the slope. The cricket sends water around the chimney so it doesn't pond behind it and leak through the flashing.
During an inspection you see the brick faces flaking and breaking off near the top of a masonry chimney. What is the most likely cause?
Answer: Water getting into the masonry followed by freeze-thaw cycles (spalling)
Spalling happens when water soaks into brick or mortar, freezes, and expands, breaking off the surface. A missing or damaged chimney cap or crown, or poor flashing, is often the source of the water. It should be reported and repair recommended.
A home inspector sees a thick, glossy black buildup inside the visible part of a wood-burning fireplace flue. What is the most appropriate action?
Answer: Report it as a possible creosote fire hazard and recommend cleaning and evaluation by a qualified chimney professional
Glazed creosote is a highly flammable byproduct of incomplete combustion and a major cause of chimney fires. Inspectors report what they observe and refer the client to a specialist, such as a chimney sweep doing a Level II inspection. Testing materials destructively is outside the inspector's role.
Written and edited by Nathan Beja, founder of Practice Test Geeks, with AI assistance. Exam facts are checked against the official sources linked below. Editorial policy
Sources & references
Exam facts on this page (fees, format, dates, passing scores) are checked against these official sources; the date is our last check. Editorial policy
- nationalhomeinspectorexam.org — Retake policy, test delivery, fees, exam format, passing score, score release, time limit · verified Nov 2026
- test-takers.psiexams.com — Registration deadline, retake fee · verified Nov 2026