  1. A technician measures superheat at the evaporator outlet and finds it is only 2°F. What condition does this indicate?

    Answer: Flooded evaporator with liquid refrigerant carry-over risk

    A superheat of 2°F at the evaporator outlet indicates a flooded coil, risking liquid refrigerant slugging the compressor.

  2. Which type of heat exchanger is most commonly used as a condenser in air-cooled commercial HVAC systems?

    Answer: Fin-and-tube coil with axial fans

    Air-cooled condensers in commercial HVAC systems typically use fin-and-tube coils with axial fans to reject heat to the outdoor air.

  3. What is the primary purpose of a crankcase heater on a refrigerant compressor?

    Answer: To prevent refrigerant migration and liquid slugging at startup

    Crankcase heaters prevent refrigerant from migrating into the oil during the off cycle, which would cause oil foaming and slugging at startup.

  4. A variable air volume (VAV) box fails to modulate airflow. Which component should the technician inspect first?

    Answer: Damper actuator and its control signal

    The damper actuator is the primary modulating component of a VAV box, and a failed actuator or missing control signal is the most common cause of no modulation.

  5. During commissioning of a chilled water system, the technician notices the entering and leaving chilled water temperature difference (ΔT) is only 4°F instead of the design 10°F. What is the most likely cause?

    Answer: Chilled water flow rate is too high

    A low ΔT across the chiller evaporator typically indicates excessive chilled water flow rate, a common symptom of low ΔT syndrome.

  6. Which refrigerant circuit component prevents high-pressure liquid from flashing to vapor before reaching the metering device?

    Answer: Subcooler or liquid-to-suction heat exchanger

    A subcooler or liquid-to-suction heat exchanger adds subcooling to the liquid refrigerant, preventing flash gas formation before the metering device.

  7. A rooftop unit's economizer damper remains fully open on a hot, humid day. Which component is most likely malfunctioning?

    Answer: Enthalpy sensor or economizer controller

    The enthalpy sensor or economizer controller determines whether outdoor conditions are suitable for free cooling; a faulty sensor can cause the damper to stay open inappropriately.