← All MRI Flashcard Decks

MRI Pulse Sequences Flashcards

7 cards from real MRI practice questions. Tap to flip, then mark Knew It or Still Learning — missed cards come back until you master them.

Read the first 7 MRI Pulse Sequences flashcards as text
  1. A technologist adds a -90° 'flip-back' pulse at the end of each echo train in a fast spin echo sequence. What is the main benefit?

    Answer: It returns residual transverse magnetization to the longitudinal axis, allowing bright fluid with a shorter TR

    Driven equilibrium (DRIVE/FRFSE/RESTORE) flips leftover transverse magnetization back to +Z so fluid stays bright on T2 images with a reduced TR.

  2. In a fast spin echo sequence, the effective TE is determined by which factor?

    Answer: The echo acquired when the central lines of k-space are filled

    Image contrast comes mostly from the center of k-space, so the echo that fills the central lines sets the effective TE.

  3. For a spoiled gradient echo sequence, the flip angle that gives maximum signal for a tissue with a given T1 and TR is called the:

    Answer: Ernst angle

    The Ernst angle, where cos θ = e^(-TR/T1), produces the highest signal for a given TR and T1.

  4. A post-contrast T1 fat-suppressed image is requested. Why is STIR a poor choice for fat suppression here?

    Answer: STIR also nulls gadolinium-enhancing tissue, since gadolinium shortens T1 toward that of fat

    STIR nulls signal by T1 rather than frequency, so enhancing tissue with T1 shortened toward fat's may be suppressed too.

  5. Time-of-flight MRA makes flowing blood bright mainly because:

    Answer: Fresh unsaturated spins enter the slice while stationary tissue is saturated by repeated short-TR pulses

    TOF uses flow-related enhancement: inflowing fully magnetized blood gives strong signal compared with saturated stationary tissue.

  6. On a phase contrast flow study, velocities above the selected VENC will cause:

    Answer: Aliasing, where high velocities are shown as flow in the opposite direction

    Phase shifts beyond ±180° wrap around, so velocities exceeding the VENC are encoded as flow in the opposite direction.

  7. Which sequence uses both magnitude and phase data from a high-resolution 3D gradient echo acquisition to highlight hemosiderin, deoxyhemoglobin, and calcification?

    Answer: Susceptibility-weighted imaging (SWI)

    SWI combines magnitude and filtered phase images to greatly increase sensitivity to susceptibility differences such as blood products and calcium.

How this page was made: written with AI tools and published by Nathan Beja, founder of Practice Test Geeks, who is responsible for its content. Exam facts are checked against the official sources listed below. Not reviewed by a subject-matter expert. Editorial policy

Sources & references

Exam facts on this page (fees, format, dates, passing scores) are checked against these official sources; the date is our last check. Editorial policy

  1. arrt.org — Passing score, score release, fees, exam information · verified Oct 2026