Structural Systems Evaluation Flashcards

7 cards from real INTERNACHI practice questions. Tap to flip, then mark Knew It or Still Learning โ€” missed cards come back until you master them.

Read the first 7 Structural Systems Evaluation flashcards as text
  1. When inspecting a wood-frame house, an inspector notices the floor joists are notched at mid-span to accommodate plumbing. What is the primary concern?

    Answer: The notch reduces shear capacity at the most critical bending zone

    Notching floor joists at mid-span significantly reduces their bending and shear capacity because mid-span is where bending stress is highest.

  2. An inspector observes stair-step cracking in a brick veneer wall near a window corner. This pattern most likely indicates:

    Answer: Differential foundation settlement

    Stair-step cracks following mortar joints near openings are a classic sign of differential foundation settlement causing racking forces in the masonry.

  3. Which condition would MOST concern an InterNACHI inspector when evaluating wood posts in a crawl space?

    Answer: Posts are sitting directly on the soil without footings

    Wood posts in direct contact with soil will wick moisture and are highly susceptible to decay and insect damage, compromising structural support.

  4. During a home inspection, an inspector finds that the ridge board in the attic has a significant sag. The MOST likely structural cause is:

    Answer: Inadequate collar ties or rafter ties allowing the rafters to spread

    A sagging ridge board typically results from rafter spread caused by missing or inadequate collar ties, allowing the roof structure to push outward and down.

  5. An inspector identifies that a load-bearing wall has been removed in a residence without a header installed. What is the most immediate structural risk?

    Answer: Transfer of loads directly to floor joists not designed for point loads

    Without a header, concentrated point loads from above transfer directly to the floor system at locations not engineered to handle them, risking structural failure.

  6. When evaluating a concrete block (CMU) foundation wall, an inspector notices horizontal cracking near mid-height. This type of crack most often results from:

    Answer: Lateral soil or hydrostatic pressure bowing the wall inward

    Horizontal cracks at mid-height of CMU foundation walls are a serious sign of lateral earth or hydrostatic pressure causing the wall to bow inward.

  7. What does the term 'bearing capacity' refer to in the context of a home inspection structural evaluation?

    Answer: The ability of the soil or structural member to support imposed loads without failure

    Bearing capacity is the maximum load per unit area that soil or a structural element can support without experiencing shear failure or excessive settlement.