← All INTERNACHI Flashcard Decks

HVAC Systems Analysis Flashcards

7 cards from real INTERNACHI practice questions. Tap to flip, then mark Knew It or Still Learning — missed cards come back until you master them.

Read the first 7 HVAC Systems Analysis flashcards as text
  1. What is the typical minimum clearance required between a gas furnace and combustible materials?

    Answer: Per manufacturer specifications

    Clearance requirements vary by furnace model and must follow the manufacturer's installation instructions, which take precedence over generic rules.

  2. Which condition indicates a cracked heat exchanger in a gas furnace?

    Answer: Yellow or orange burner flame

    A cracked heat exchanger allows combustion gases to mix with supply air, causing the burner flame to roll out or appear yellow/orange due to disrupted airflow.

  3. What does SEER stand for in relation to air conditioning equipment?

    Answer: Seasonal Energy Efficiency Ratio

    SEER (Seasonal Energy Efficiency Ratio) measures cooling output divided by electrical energy input over a typical cooling season.

  4. A home inspector notices the condensate drain line on an air handler is dripping water at the connection joint. What should be reported?

    Answer: Improper drain line installation or joint failure requiring repair

    A leaking condensate drain joint indicates a failed or improperly installed connection that can cause water damage and should be repaired by a qualified technician.

  5. Which component in a heat pump system reverses the refrigerant flow to switch between heating and cooling modes?

    Answer: Reversing valve (four-way valve)

    The reversing valve (four-way valve) redirects refrigerant flow so the heat pump can absorb heat from outside in winter or reject heat outside in summer.

  6. What is the recommended maximum temperature rise across a gas furnace heat exchanger?

    Answer: 35–70°F

    Most gas furnaces are designed for a temperature rise of 35–70°F across the heat exchanger; values outside this range indicate airflow or equipment issues.

  7. During an inspection, you observe rust staining and moisture around the base of a furnace flue pipe. What is the most likely cause?

    Answer: Flue gas backdrafting or improper venting

    Rust and moisture at a conventional furnace flue indicate that combustion gases are condensing inside the vent, typically due to backdrafting or undersized flue pipe.