  1. Under IECC 2021, what is the minimum continuous air barrier requirement for commercial buildings regarding tested leakage?

    Answer: 0.25 cfm/ft² at 75 Pa

    IECC 2021 requires commercial buildings to achieve an air leakage rate no greater than 0.25 cfm/ft² at a pressure differential of 75 Pa.

  2. Which ICC certification specifically covers energy inspection in residential construction projects?

    Answer: Residential Energy Inspector/Plans Examiner (REIPE)

    The ICC Residential Energy Inspector/Plans Examiner (REIPE) credential covers energy code compliance for residential construction.

  3. In ASHRAE 90.1, what is the primary method used to establish a baseline building model for the Energy Cost Budget path?

    Answer: Appendix G Performance Rating Method

    Appendix G of ASHRAE 90.1 defines the Performance Rating Method and provides the baseline building model rules for the Energy Cost Budget compliance path.

  4. A building's solar heat gain coefficient (SHGC) requirement is MOST directly related to which climate characteristic?

    Answer: Annual cooling degree days

    SHGC limits are driven primarily by cooling load potential, which correlates with annual cooling degree days in a given climate zone.

  5. Which section of the IECC addresses the commissioning requirements for commercial mechanical systems?

    Answer: Section C408

    IECC Section C408 outlines the systems commissioning and completion requirements for commercial HVAC, lighting, and other mechanical systems.

  6. When performing a whole-building energy simulation, which software tool is listed in ASHRAE 90.1 Appendix G as an approved simulation program?

    Answer: EnergyPlus

    EnergyPlus is one of the DOE-validated whole-building energy simulation programs approved for use under ASHRAE 90.1 Appendix G compliance.

  7. Under the IECC 2021 residential provisions, the maximum fenestration U-factor for Climate Zone 5 is:

    Answer: 0.30

    IECC 2021 Table R402.1.2 specifies a maximum fenestration U-factor of 0.30 for Climate Zone 5 residential buildings.

How this page was made: written with AI tools and published by Nathan Beja, founder of Practice Test Geeks, who is responsible for its content. Exam facts are checked against the official sources listed below. Not reviewed by a subject-matter expert. Editorial policy

Sources & references

Exam facts on this page (fees, format, dates, passing scores) are checked against these official sources; the date is our last check. Editorial policy

  1. iccsafe.org — Renewal, score validity, test delivery, retake policy, time limit, retake fee · verified Oct 2026
  2. pearsonvue.com — Registration · verified Oct 2026