HUD Structural and Mechanical Systems Flashcards
6 cards from real HUD practice questions. Tap to flip, then mark Knew It or Still Learning — missed cards come back until you master them.
Read the first 6 HUD Structural and Mechanical Systems flashcards as text
A HUD inspector finds that the central air conditioning system is non-functional in July in Phoenix, Arizona. How should this be documented?
Answer: Evaluated based on whether the unit can maintain a safe interior temperature; may be a fail in extreme heat climates
HQS does not universally require air conditioning, but PHAs in extreme heat climates may designate it as a required feature; the inspector evaluates based on local standards and health risk.
Which of the following plumbing conditions is considered a standard (non-life-threatening) HQS fail?
Answer: A corroded but functional pressure relief valve on the water heater
A corroded but still-functional TPR valve is a standard deficiency requiring correction within 30 days; it's not immediately life-threatening unlike a gas leak or sewage backup.
When inspecting a HUD-assisted home, an inspector finds that the exterior foundation has large horizontal cracks. What does this most likely indicate?
Answer: Lateral soil pressure causing structural bowing or failure of the foundation wall
Large horizontal cracks in a foundation wall typically indicate lateral soil pressure that is bowing or shearing the wall — a serious structural deficiency requiring engineering evaluation.
Under HUD standards, what is the minimum insulation R-value required in an attic for a home in a heating-dominated climate zone?
Answer: R-30 to R-38 depending on climate zone
HUD and energy codes require R-30 to R-38 (or higher) in attics for heating-dominated climates; the exact value depends on the specific climate zone designation.
What is the purpose of a 'P-trap' under a plumbing fixture, as evaluated in a HUD inspection?
Answer: To hold water that blocks sewer gases from entering the living space
A P-trap holds a water seal that prevents toxic and odorous sewer gases from entering the living space; a missing or dry trap is a health and safety deficiency.
A HUD inspector finds evidence of active termite infestation in the floor system of an assisted unit. This should be documented as:
Answer: A structural safety deficiency requiring professional pest control and structural evaluation
Active termite infestation is a structural safety concern under HQS because termites can compromise load-bearing members; it requires pest treatment and assessment of existing structural damage.
How this page was made: written with AI tools and published by Nathan Beja, founder of Practice Test Geeks, who is responsible for its content. Exam facts are checked against the official sources listed below. Not reviewed by a subject-matter expert. Editorial policy