Energy Efficiency and Weatherization Standards Flashcards

7 cards from real HUD practice questions. Tap to flip, then mark Knew It or Still Learning — missed cards come back until you master them.

Read the first 7 Energy Efficiency and Weatherization Standards flashcards as text
  1. What federal program provides grants to states and local agencies to improve the energy efficiency of low-income households?

    Answer: Weatherization Assistance Program (WAP)

    The Weatherization Assistance Program (WAP), administered by the U.S. Department of Energy, funds energy efficiency improvements for low-income households.

  2. Which insulation R-value is typically required by HUD for attic insulation in most climate zones to meet current energy standards?

    Answer: R-38 or higher

    HUD and modern energy codes generally require R-38 or higher for attic insulation in most U.S. climate zones to achieve adequate thermal performance.

  3. During a HUD energy inspection, what does a 'blower door test' measure?

    Answer: Air infiltration and building envelope leakage

    A blower door test depressurizes the building to measure air infiltration rates, identifying leaks in the building envelope that reduce energy efficiency.

  4. What is the minimum window U-factor typically required for HUD-assisted new construction in a cold climate zone?

    Answer: 0.35

    HUD energy standards aligned with IECC require window U-factors of 0.35 or lower in cold climate zones to limit heat loss through glazing.

  5. Which document provides the primary energy efficiency guidelines that HUD-assisted new construction projects must comply with?

    Answer: International Energy Conservation Code (IECC)

    HUD requires that new construction and substantial rehabilitation projects comply with the International Energy Conservation Code (IECC) as the baseline energy standard.

  6. When inspecting a HUD property, which area is typically the most significant source of uncontrolled air infiltration?

    Answer: Penetrations around plumbing, electrical, and HVAC systems

    Penetrations where plumbing, electrical conduits, and HVAC systems pass through the building envelope are typically the largest sources of uncontrolled air leakage.

  7. What SEER rating is the current federal minimum for new central air conditioning systems installed in HUD-assisted housing in the southern United States?

    Answer: 14 SEER

    As of 2023, the federal minimum SEER rating for new central air conditioners in the southern U.S. region is 14 SEER under DOE standards referenced by HUD.

How this page was made: written with AI tools and published by Nathan Beja, founder of Practice Test Geeks, who is responsible for its content. Exam facts are checked against the official sources listed below. Not reviewed by a subject-matter expert. Editorial policy