Histology Techniques & Technology Flashcards
7 cards from real HT practice questions. Tap to flip, then mark Knew It or Still Learning — missed cards come back until you master them.
Read the first 7 Histology Techniques & Technology flashcards as text
According to OSHA's Hazard Communication Standard, what document provides detailed safety information about a specific chemical, including handling, storage, and first-aid measures?
Answer: Safety Data Sheet (SDS)
The Safety Data Sheet (SDS), previously called MSDS, is the standardized document required by OSHA's HazCom Standard to communicate chemical hazards and safe handling procedures.
Xylene substitutes (xylene alternatives) are increasingly used in tissue processing primarily to reduce exposure to which hazard?
Answer: Volatile organic compounds (VOCs) with hepatotoxic and neurotoxic potential
Xylene is a volatile organic compound with recognized hepatotoxic and neurotoxic properties; xylene substitutes reduce worker exposure while maintaining clearing efficacy.
What is the purpose of a proficiency testing (PT) program for a histology laboratory?
Answer: To externally verify laboratory performance and ensure accurate results
Proficiency testing programs send unknown specimens to the laboratory for testing; results are compared to peer laboratories to verify that the lab's methods are accurate and reproducible.
In histology, what is the term for the gradual fading of a stained section over time when exposed to light?
Answer: Photobleaching (fading)
Photobleaching or fading occurs when light energy breaks the chromophore bonds in dye molecules, causing loss of color intensity in stained sections.
Which of the following describes the correct sequence for deparaffinization before routine H&E staining?
Answer: Xylene → graded alcohols → water
Deparaffinization begins with xylene to dissolve paraffin, then graded alcohols to remove xylene, and finally water to hydrate the tissue for aqueous staining.
Automated tissue processors in the histology lab are most commonly operated using which processing mode to prevent overnight tissue damage?
Answer: Timed or continuous carousel with vacuum/pressure cycles
Modern automated processors use timed cycles with vacuum and/or pressure to accelerate reagent penetration and can be programmed to complete processing just before the next workday begins.
A technician notices that sections consistently show a thick, uneven ribbon during paraffin sectioning in winter. The MOST likely cause is:
Answer: The paraffin block is too cold, causing compression
Cold paraffin blocks compress during sectioning rather than cutting cleanly; warming the block face slightly with a warm hand or lamp helps produce even ribbons.
How this page was made: written with AI tools and published by Nathan Beja, founder of Practice Test Geeks, who is responsible for its content. Exam facts are checked against the official sources listed below. Not reviewed by a subject-matter expert. Editorial policy
Sources & references
Exam facts on this page (fees, format, dates, passing scores) are checked against these official sources; the date is our last check. Editorial policy
- ascp.org — Renewal, score validity, score release, retake policy, test dates, registration deadline, test delivery, exam format, passing score, fees · verified Oct 2026