← All HIS Flashcard Decks

Pure Tone & Speech Audiometry Flashcards

6 cards from real HIS practice questions. Tap to flip, then mark Knew It or Still Learning — missed cards come back until you master them.

Read the first 6 Pure Tone & Speech Audiometry flashcards as text
  1. What does Word Recognition Score (WRS) measure and at what presentation level is it typically assessed?

    Answer: The percentage of monosyllabic words correctly identified when presented at a comfortable listening level (typically MCL or 40 dB SL re: SRT)

    WRS (also called speech discrimination score) is the percentage of phonetically balanced monosyllabic words correctly repeated when presented at a suprathreshold comfortable level, reflecting speech clarity independent of loudness.

  2. An audiogram shows identical air and bone conduction thresholds of 65 dB HL with no air-bone gap. What type of hearing loss is present?

    Answer: Sensorineural hearing loss

    When air conduction and bone conduction thresholds are equal with no air-bone gap, the loss is sensorineural, indicating inner ear (cochlear) or auditory nerve pathology rather than a middle ear problem.

  3. What is the purpose of the modified Hughson-Westlake procedure in pure tone audiometry?

    Answer: To establish accurate behavioral hearing thresholds using a standardized ascending-descending bracketing method

    The modified Hughson-Westlake procedure is a standardized threshold-seeking method using a 10 dB down, 5 dB up bracketing approach, where threshold is defined as the lowest level with 50% correct responses in ascending trials.

  4. What does a type B tympanogram indicate?

    Answer: Middle ear fluid (effusion) or a perforated tympanic membrane

    A type B tympanogram is flat with no peak, indicating no movement of the tympanic membrane with pressure changes—most commonly caused by middle ear effusion but also seen with tympanic membrane perforation.

  5. Why is it important to re-test 1000 Hz at the end of a pure tone audiometry test battery?

    Answer: As a reliability check—the retest threshold should agree within 5 dB of the original to confirm test validity

    Retesting 1000 Hz at the end of the audiogram serves as a test-retest reliability check. Agreement within 5 dB indicates consistent, valid patient responses; a larger discrepancy suggests possible response variability or non-organic factors.

  6. What is the Carhart notch and with which condition is it associated?

    Answer: A notch at 2000 Hz in bone conduction thresholds, associated with otosclerosis

    The Carhart notch is a characteristic dip in bone conduction thresholds at 2000 Hz seen in otosclerosis. It is a mechanical artifact of stapes fixation, not representing true cochlear damage.

How this page was made: written with AI tools and published by Nathan Beja, founder of Practice Test Geeks, who is responsible for its content. Exam facts are checked against the official sources listed below. Not reviewed by a subject-matter expert. Editorial policy

Sources & references

Exam facts on this page (fees, format, dates, passing scores) are checked against these official sources; the date is our last check. Editorial policy

  1. myhome.ihsinfo.org — Passing score, retake fee, score release, test dates, exam information · verified Nov 2026
  2. ihsinfo.org — Exam format, time limit, test delivery, eligibility, fees · verified Oct 2026