Blower Door & Duct Testing Flashcards

21 cards from real HERS practice questions. Tap to flip, then mark Knew It or Still Learning — missed cards come back until you master them.

Read the first 20 Blower Door & Duct Testing flashcards as text
  1. During a blower door test, what effect does a large open fireplace damper have on the result?

    Answer: It increases the measured CFM50, making the house appear leakier

    An open fireplace damper is a large pathway to outside and will increase the measured infiltration (CFM50), inflating the apparent leakage of the building shell.

  2. What is the primary reason HERS raters must depressurize ducts to a specific pressure (typically 25 Pa) during a duct leakage test?

    Answer: To standardize results so tests from different homes and raters are comparable

    Standardizing at 25 Pa ensures that duct leakage measurements are consistent and comparable across different test conditions, homes, and raters.

  3. In a duct leakage test, CFM25 total is measured at 300 cfm and CFM25 out is measured at 180 cfm. What is the duct leakage to outside?

    Answer: 120 cfm

    Duct leakage to outside equals total leakage minus leakage to conditioned space: 300 − 180 = 120 cfm.

  4. Which condition must be established before starting a blower door test according to RESNET standards?

    Answer: All interior doors must be open

    RESNET requires all interior doors to be open so that the entire conditioned envelope is pressurized or depressurized uniformly during testing.

  5. What does a high ELA (Effective Leakage Area) value indicate about a home?

    Answer: The home has a large equivalent hole size and poor air sealing

    A high ELA means the combined leakage pathways are equivalent to a large hole, indicating poor envelope air tightness.

  6. During duct leakage testing, why is it important to seal all supply and return grilles before testing?

    Answer: To isolate duct leakage from building envelope leakage

    Sealing grilles ensures that airflow measured by the duct blaster represents only leakage through duct seams and connections, not intentional supply/return openings.

  7. A home tests at 6 ACH50. Which HERS reference home air leakage rate would this most closely correspond to for a typical new construction standard?

    Answer: It exceeds the typical new construction benchmark of 3 ACH50

    A common new construction benchmark is 3 ACH50 or less; 6 ACH50 is twice that limit, indicating the home is leakier than typical code expectations.

  8. What is the purpose of the pressure pan test in duct diagnostics?

    Answer: To locate which registers have the greatest duct leakage to outside

    A pressure pan placed over each register measures the pressure difference behind it, identifying registers associated with ducts that leak outside the conditioned space.

  9. During a blower door test, which measurement channel on the manometer typically reads building pressure with respect to outside?

    Answer: The differential channel (B-A or A-B)

    The differential channel measures the pressure difference between inside and outside (or across the blower door fan), which is the key value for calculating air leakage.

  10. A rater finds that CFM25 out (duct leakage to outside) exceeds the RESNET threshold for the home size. What is the most appropriate next step?

    Answer: Report the result and recommend duct sealing, then retest

    When duct leakage exceeds thresholds, the rater reports the finding, recommends corrective duct sealing by the contractor, and then conducts a retest to verify compliance.

  11. What term describes duct leakage that exits into an unconditioned space such as an attic or crawlspace?

    Answer: Duct leakage to outside

    Duct leakage that goes into unconditioned spaces (attic, crawlspace, garage) is called duct leakage to outside because it effectively leaves the conditioned envelope.

  12. Which instrument is used to simultaneously measure fan flow and building pressure difference during a blower door test?

    Answer: Digital manometer connected to the blower door fan and building

    A digital manometer measures both the pressure difference across the building envelope and the flow through the blower door fan, allowing CFM50 to be calculated.

  13. For HERS rating purposes, what does 'verified duct leakage' mean when ducts are entirely inside conditioned space?

    Answer: The rater may use a default duct leakage value without testing

    When all ducts are confirmed to be within the conditioned envelope, RESNET allows raters to use a default duct leakage assumption rather than requiring a measured test.

  14. What is the typical baseline depressurization target for a blower door test per ASTM E779?

    Answer: 50 Pa

    ASTM E779 and RESNET protocols specify 50 Pascals as the reference depressurization pressure, which is why results are expressed as CFM50.

  15. A rater suspects that wind is affecting blower door readings. Which technique helps compensate for wind-induced pressure fluctuations?

    Answer: Take multiple fan pressure readings and average them

    Averaging multiple readings or using a data-logging manometer to record many samples over time compensates for short-term wind pressure fluctuations.

  16. Which metric best represents the air tightness of a home independent of its volume?

    Answer: ACH50

    ACH50 (air changes per hour at 50 Pa) normalizes CFM50 by home volume, allowing meaningful comparisons between homes of different sizes.

  17. During a duct blaster test, the technician notices pressure in the duct system won't reach 25 Pa even at maximum fan speed. What is the most likely cause?

    Answer: There is a large unsealed duct opening or disconnected duct section

    If the duct blaster cannot reach 25 Pa, it usually means there is an extremely large leak—such as a disconnected duct section or an unsealed chase—allowing air to escape faster than the fan can pressurize the system.

  18. What is the formula for converting CFM50 to ACH50?

    Answer: ACH50 = CFM50 × 60 / conditioned volume (ft³)

    ACH50 = (CFM50 × 60 min/hr) ÷ conditioned volume in cubic feet, converting the per-minute flow to an hourly air change rate.

  19. In a duct leakage test, what does a very low CFM25 out reading (near zero) with a relatively high CFM25 total reading suggest?

    Answer: The duct system has significant leaks, all within the conditioned space

    High total leakage with near-zero outside leakage means ducts are leaking significantly but all the leakage goes into conditioned space, not to unconditioned areas.

  20. Which RESNET-recognized testing method allows duct leakage to be measured without pressurizing or depressurizing the entire duct system?

    Answer: Delta Q method

    The Delta Q method estimates duct leakage to outside by comparing house pressure with the air handler running versus off, without using a duct blaster.