FC FC Electrical Components & Controls 1 — Questions and Answers
Question 1: What is the typical control voltage used in residential furnace control circuits?
- 12V DC
- 24V AC (Correct answer)
- 120V AC
- 240V AC
Correct answer: 24V AC
Most residential furnace control circuits operate at 24V AC, supplied by a step-down transformer inside the furnace.
Question 2: What is the function of the furnace transformer?
- Powers the blower motor
- Steps 120V down to 24V for the control circuit (Correct answer)
- Converts AC to DC for the igniter
- Regulates gas valve current
Correct answer: Steps 120V down to 24V for the control circuit
The step-down transformer reduces 120V line voltage to 24V AC to power the thermostat and control board.
Question 3: Which furnace safety control opens the circuit if the heat exchanger area overheats?
- Pressure switch
- Rollout switch
- High-limit switch (Correct answer)
- Draft proving switch
Correct answer: High-limit switch
The high-limit switch monitors supply air temperature and opens the control circuit if the heat exchanger area exceeds a safe temperature.
Question 4: What does a rollout switch do when it trips?
- Shuts off the blower motor
- Shuts off the gas valve because flames have rolled out of the combustion chamber (Correct answer)
- Resets the thermostat
- Opens the fresh air damper
Correct answer: Shuts off the gas valve because flames have rolled out of the combustion chamber
A rollout switch detects flame rollout from the combustion area and interrupts the gas valve circuit to prevent a fire hazard.
Question 5: The flame sensor (flame rod) in a furnace operates on which principle?
- Resistance change with temperature
- Flame rectification of AC current to DC microamps (Correct answer)
- Thermocouple millivoltage generation
- Optical infrared detection
Correct answer: Flame rectification of AC current to DC microamps
The flame rod uses flame rectification, where the ionized flame conducts AC asymmetrically, producing a measurable DC microamp signal.
Question 6: What minimum flame signal (microamps DC) is typically required for a furnace flame sensor to keep the gas valve open?
- 0.1 µA
- 0.5–1.0 µA (Correct answer)
- 5–10 µA
- 25 µA
Correct answer: 0.5–1.0 µA
Most furnace control boards require at least 0.5–1.0 µA of DC flame signal to confirm ignition and hold the gas valve open.
What is the typical control voltage used in residential furnace control circuits?