← All F-01 Flashcard Decks

Mixed Deck — All F-01 Topics Flashcards

100 cards from real F-01 practice questions. Tap to flip, then mark Knew It or Still Learning — missed cards come back until you master them.

Read the first 20 Mixed Deck — All F-01 Topics flashcards as text
  1. A contractor leaves oily rags in a pile near a heat source during a hot work operation. As the fireguard, you should:

    Answer: Immediately stop work and require proper disposal of the rags

    Oily rags near heat sources are a serious spontaneous combustion hazard; the fireguard has authority to stop work until the hazard is corrected.

  2. Who must be notified before any planned fire protection system impairment begins in New York City?

    Answer: The local fire department and the building's insurance carrier

    FDNY regulations require that both the local fire department and the building's insurance carrier be notified before a planned impairment begins, ensuring proper oversight and coverage during the vulnerable period.

  3. Who is responsible for ensuring that fire extinguishers are immediately available at a hot work site?

    Answer: The fireguard assigned to the hot work area

    The fireguard on duty at the hot work location must confirm that operable, appropriate fire extinguishers are staged within reach before work begins.

  4. What type of fire protection system impairment requires an F-01 fire guard?

    Answer: Any impairment to fire protection systems including sprinklers, alarms, and standpipes

    An F-01 fire guard is required for any impairment to fire protection systems.

  5. While conducting a fire watch, a fire guard notices a stairwell exit door is propped open with a door stopper. What is the correct action?

    Answer: Remove the obstruction and ensure the door closes and latches properly

    Stairwell doors must remain closed and latched to prevent smoke and fire from spreading between floors. A fire guard must immediately remove any obstruction keeping a fire door open, as these doors are a critical barrier in life-safety systems.

  6. If the fire alarm system goes into trouble mode (supervisory signal), what should the fireguard do?

    Answer: Log the trouble signal, notify the building engineer or supervisor, and monitor the system for changes

    A trouble/supervisory signal indicates a fault in the system (such as a low battery or open circuit) that must be documented, reported, and investigated to ensure the system remains operational.

  7. When a fireguard discovers a fire, what is the FIRST action they should take?

    Answer: Activate the nearest fire alarm pull station

    The first action is always to activate the nearest fire alarm pull station to alert occupants and summon the FDNY.

  8. Before restoring a fire suppression system after an impairment, the Impairment Coordinator must confirm that:

    Answer: All valves are fully open and the system has been tested for proper operation

    Confirming all valves are open and the system tests properly ensures the building returns to full fire protection before ending the impairment.

  9. What should the fire guard advise about elevator use during evacuation?

    Answer: Advise occupants not to use elevators and direct them to stairways

    Elevators are dangerous during fires; occupants should use stairways.

  10. In a wet-pipe sprinkler system, the pipes are filled with:

    Answer: Water under pressure

    Wet-pipe sprinkler systems keep the pipes constantly filled with pressurized water, allowing for immediate discharge when a sprinkler head activates.

  11. A restaurant kitchen has grease buildup in the exhaust hood filters. This is a fire hazard primarily because:

    Answer: Accumulated grease is highly combustible and can ignite from cooking heat

    Grease is highly flammable and accumulated grease in exhaust filters can ignite from heat, causing a fast-spreading fire.

  12. A sprinkler system is out of service during renovation. The fireguard's patrol frequency during this impairment should be:

    Answer: Increased to compensate for the loss of automatic fire suppression

    When a fire suppression system is impaired, patrol frequency must increase because the automatic safeguard is unavailable.

  13. A fireguard on duty at a construction site observes workers discarding oily rags in a pile on the floor at the end of the workday. What fire hazard does this create?

    Answer: Oil-soaked rags can undergo spontaneous combustion as the oil oxidizes and generates heat

    Certain oils, particularly linseed oil, oxidize and release heat as they cure; piled rags insulate this heat, potentially causing spontaneous ignition.

  14. If an assembly event is taking place and the building's fire alarm system activates, the fire guard should FIRST:

    Answer: Begin immediate orderly evacuation of all occupants

    Every fire alarm activation must be treated as a real emergency; immediate, orderly evacuation of all occupants must begin.

  15. Which document must the fireguard maintain to record all fire watch patrols during a system impairment?

    Answer: Impairment log or fire watch log

    An impairment log or fire watch log documenting time, route, and findings must be kept throughout the impairment.

  16. What should candidates do the day before the F-01 exam?

    Answer: Review key concepts, prepare documents, and get adequate rest

    Final review of key concepts, gathering documents, and getting rest leads to better performance.

  17. A stored-pressure fire extinguisher has a gauge reading in the green zone but the hose is cracked. What should the fireguard do?

    Answer: Tag it out of service and report it for repair

    A cracked hose is a defect that renders the extinguisher unserviceable; it must be removed from service and repaired by a certified technician.

  18. An F-01 Certificate of Fitness holder is required to be present:

    Answer: Continuously throughout all hot work operations and during the post-work watch

    The fireguard must maintain a continuous presence throughout all hot work and during the mandatory post-work monitoring period.

  19. Which of the following actions is considered outside the scope of duties for an F-01 Fire Guard on patrol?

    Answer: Attempting to reset a tripped circuit breaker in the main electrical panel.

    A Fire Guard's role is fire watch and safety, not electrical or system maintenance. Attempting to work on electrical panels is dangerous, requires a different qualification, and is not a part of their prescribed duties. Their role is to observe, report, and notify.

  20. What should a fire guard do during a false alarm while on fire watch?

    Answer: Respond as real until confirmed otherwise

    Treat every alarm as real until confirmed false.