EPA System Recovery and Evacuation Procedures Flashcards

6 cards from real EPA practice questions. Tap to flip, then mark Knew It or Still Learning — missed cards come back until you master them.

Read the first 6 EPA System Recovery and Evacuation Procedures flashcards as text
  1. What is the required recovery level (in inches of mercury vacuum) for systems with less than 200 pounds of refrigerant manufactured before November 15, 1993, when using recovery-only equipment made before that date?

    Answer: 4 inches Hg vacuum

    For pre-1993 systems under 200 lbs using pre-1993 recovery equipment, the required evacuation level is 4 inches of mercury vacuum.

  2. Before opening a refrigeration system for major repairs, what must a technician do first?

    Answer: Recover the refrigerant from the system

    Federal regulations under Section 608 require technicians to recover refrigerant before opening any system to prevent venting to the atmosphere.

  3. What is the evacuation requirement for small appliances (systems containing 5 lbs or less of refrigerant) during recovery?

    Answer: 80% recovery if the compressor is not operating

    For small appliances with inoperative compressors, EPA requires recovery of 80% of refrigerant; if the compressor operates, 90% recovery is required.

  4. What is the primary purpose of deep evacuation before charging a refrigeration system?

    Answer: To remove moisture and non-condensable gases from the system

    Deep evacuation removes moisture and non-condensable gases (such as air and nitrogen) that can cause acid formation, elevated pressures, and system damage.

  5. Which instrument is used to measure the vacuum level during system evacuation?

    Answer: Electronic micron gauge (vacuum gauge)

    An electronic micron gauge accurately measures deep vacuum levels in microns of mercury (μm Hg), which manifold gauges cannot read precisely enough.

  6. What does a 'standing vacuum test' verify after system evacuation?

    Answer: That the system holds the required vacuum without rising, confirming no leaks or moisture

    A standing vacuum test confirms system integrity by isolating the vacuum pump and monitoring whether the system vacuum holds steady or rises, indicating leaks or residual moisture.