← All EPA Flashcard Decks

Regulatory Requirements & Compliance Flashcards

7 cards from real EPA practice questions. Tap to flip, then mark Knew It or Still Learning — missed cards come back until you master them.

Read the first 7 Regulatory Requirements & Compliance flashcards as text
  1. Which tasks must be performed or directed on-site by the certified renovator rather than delegated to an untrained worker?

    Answer: Posting warning signs, establishing containment, and cleaning verification

    The certified renovator must be physically present while signs are posted, containment established, and cleaning done, and must personally perform cleaning verification.

  2. How must non-certified workers on an RRP job be trained?

    Answer: On-the-job training by a certified renovator in the work practices they perform

    Non-certified workers must receive on-the-job training from a certified renovator, which must be documented.

  3. A certified renovator uses an EPA-recognized test kit and finds no lead. Within how many days of completing the renovation must the firm provide the owner with documentation of the results?

    Answer: 30 days

    Test kit results documentation must be provided to the client within 30 days of completing the renovation.

  4. Instead of using a test kit, a certified renovator may collect paint chip samples and send them to:

    Answer: An NLLAP-recognized laboratory

    Paint chip samples must be analyzed by a laboratory recognized under EPA's National Lead Laboratory Accreditation Program.

  5. How is the RRP Rule enforced in a state that has received EPA authorization?

    Answer: The authorized state administers and enforces its own program

    EPA authorizes states, tribes, and territories to run their own RRP programs in lieu of the federal program.

  6. Civil penalties for RRP Rule violations are assessed on what basis?

    Answer: Per violation, per day, adjusted annually for inflation

    EPA can assess civil penalties per violation per day, with maximums adjusted annually for inflation.

  7. If the cleaning verification cloth fails twice for the same area, what must the certified renovator do next?

    Answer: Wait one hour or until dry, then wipe with an electrostatic dry cloth

    After two failed wet-cloth attempts, wait 1 hour or until dry and wipe with a dry electrostatic cloth to complete verification.

Written and edited by , founder of Practice Test Geeks, with AI assistance. Exam facts are checked against the official sources linked below. Editorial policy

Sources & references

Exam facts on this page (fees, format, dates, passing scores) are checked against these official sources; the date is our last check. Editorial policy

  1. epa.gov — Passing score, eligibility, renewal, retake policy, score release, score validity, exam information · verified Nov 2026
  2. ecfr.gov — Test delivery, exam information · verified Oct 2026