  1. A technician is recovering refrigerant and the recovery cylinder reaches its maximum safe fill. What is the maximum fill level allowed?

    Answer: 80% of water capacity

    Cylinders must never be filled above 80% of capacity to leave room for liquid expansion.

  2. Recovery on a system is slow near the end of the process. Which action is most likely to speed it up?

    Answer: Cooling the recovery cylinder in an ice bath or with a chiller

    Chilling the recovery cylinder lowers its pressure and draws vapor in faster.

  3. What is the main advantage of the push-pull method of recovery?

    Answer: It recovers large amounts of liquid refrigerant quickly

    Push-pull uses pressure differential to move liquid between the system and a cylinder, much faster than vapor recovery.

  4. A technician recovers R-22 from a small appliance made after November 15, 1993 using a recovery machine. What level of recovery must be achieved for a high-pressure appliance with less than 200 lb of charge using equipment manufactured after that date?

    Answer: 0 inches Hg (0 psig)

    HCFC-22 appliances with under 200 lb require recovery to 0 psig (0 inches Hg) with post-1993 equipment.

  5. What can happen if a technician mixes two different refrigerants in the same recovery cylinder?

    Answer: The mixture may only be reclaimed or destroyed by an appropriate facility and cannot simply be reused

    Mixed refrigerants must be sent to a reclaimer or destruction facility and cannot be recharged into equipment.

  6. A technician must recover from a low-pressure chiller. Why must the technician apply heat or circulate water through the tubes during recovery?

    Answer: To prevent freezing of water in the tubes when pressure drops

    Boiling refrigerant at low pressure can freeze water in the chiller tubes and rupture them.

  7. A recovery machine stops and the cylinder pressure is much higher than the system pressure. What is the most likely cause?

    Answer: The machine's high-pressure cutout tripped due to a full or hot cylinder

    Back pressure from a full or warm cylinder can trip the recovery machine's high-pressure safety control.

Written and edited by , founder of Practice Test Geeks, with AI assistance. Exam facts are checked against the official sources linked below. Editorial policy

Sources & references

Exam facts on this page (fees, format, dates, passing scores) are checked against these official sources; the date is our last check. Editorial policy

  1. ecfr.gov — Exam format, test delivery, fees, passing score, retake policy, score release · verified Oct 2026
  2. epa.gov — Test delivery, eligibility, renewal, score validity · verified Oct 2026