Leadership & Team Management Flashcards

7 cards from real EPA 608 practice questions. Tap to flip, then mark Knew It or Still Learning — missed cards come back until you master them.

Read the first 7 Leadership & Team Management flashcards as text
  1. A crew lead has an uncertified helper recover refrigerant alone while the lead works on another job. What is the correct leadership decision?

    Answer: Reassign so a certified technician performs or directly supervises the recovery

    Only certified technicians may perform refrigerant-releasing work, and trainees must be directly supervised by one.

  2. How long must records of leak repairs on appliances with 50 or more pounds of refrigerant be kept?

    Answer: 3 years

    EPA requires owners and operators to keep leak repair and service records for 3 years.

  3. Where must a technician keep proof of Section 608 certification so a supervisor can produce it for an inspector?

    Answer: At the technician's place of business

    Technicians must keep proof of certification at their place of business and make it available for inspection.

  4. A team lead briefs the crew on filling a recovery cylinder. What is the maximum fill level?

    Answer: 80% of capacity

    Recovery cylinders must never be filled beyond 80% by volume to leave room for thermal expansion.

  5. A new technician proposes pressure testing a system with oxygen because the nitrogen cylinder is empty. What should the lead say?

    Answer: Never use oxygen; use dry nitrogen with a regulator

    Oxygen with oil can explode, so systems are pressure tested with dry nitrogen through a regulator.

  6. A technician asks about the consequence of knowingly venting refrigerant. Which statement is accurate?

    Answer: Civil penalties can exceed $40,000 per day per violation

    Violations of the venting prohibition carry civil penalties that exceed $40,000 per day per violation.

  7. A lead assigns a technician holding only Type I certification to service a residential split air conditioner. Is this appropriate?

    Answer: No, high-pressure appliances require Type II or Universal

    Type I covers small appliances of 5 lb or less, while high-pressure systems like split ACs need Type II or Universal.

Written and edited by , founder of Practice Test Geeks, with AI assistance. Exam facts are checked against the official sources linked below. Editorial policy

Sources & references

Exam facts on this page (fees, format, dates, passing scores) are checked against these official sources; the date is our last check. Editorial policy

  1. ecfr.gov — Exam format, test delivery, fees, passing score, retake policy, score release · verified Oct 2026
  2. epa.gov — Test delivery, eligibility, renewal, score validity · verified Oct 2026